USER GUIDE & SER V ICE MANU AL
RIGHT PR ODUCT . RIGHT PLA C E. RIGHT TEMPERA T URE. SINCE 1962.
SAFETY • INST ALLA TION & I NTEGRA TION • OPERA TI NG I N STR U CTIONS • MAINTENANCE • SER V I CE
Modular 3000 Series • 3060D WR • 60 cm Drawer Model
USER GUID E
u - l i n e. c o m
Contents
SAFETY • INSTALLATION & INTEGRATION • OPERATI N G INSTRUCTIONS • MAINTENANCE • SERVICE
Intro
Safety
Safety and Warning
Disposal and Recycling
Installation
Environmental Requirements
Electrical
Cutout Dimensions
Product Dimensions
Anti-Tip Bracket
General Installation
Integrated Panel Dimensions
Integrated Grille / Plinth Dimensions
Integrated Panel Installation
Troubleshooting
Warranty
Service Extended
Wire Diagram
Product Liability
Warranty Claims
Ordering Replacement Parts
System Diagnosis Guide
Compressor Specifications
Troubleshooting Extended
Control Quick Guide
Thermistor
Defrost
Remove Fan and Cover
Grille / Plinth Installation
Drawers
Operating Instructions
First Use
Control Operation
Sabbath Mode
Airflow and Product Loading
Maintenance
Cleaning
Cleaning Condenser
Extended Non-Use
Service
USER GUIDE
u- li n e . c om
WEL C OME T O U-LINE
C o ngr a tulati ons on y o ur U-Li ne purc hase . Y o ur pr oduc t com e s f r om a c o mpany w i th ov er fi v e decades of pr emium mod u lar
ic e ma ki n g , refr igera t i o n, an d wi ne pr eserv ation exp e rience . U-Li ne c o nt in ues to b e t h e Am eri c a n lea d er , d e liver i ng vers at ili t y
a n d fl ex ibi l it y f o r mul t ipl e ap pli c a t i on s in cl udi n g r e si den t i a l , li ght commerc i al , out d oor and ma ri ne us e . U-Lin e ’ s comp lete
global product collection includ es W i n e Cellars , Dri n k s C a bi nets , Clear I c e Mach ines , Gl ass & Sol i d Door R e frigerators , Draw er
Models , and F r eezers .
U-Li ne has ca pt iv a t ed those wi th a n a p prec i ati on f o r t h e fi ner things wi th ex c e pti o na l func ti ona l i t y , st yle, i n s p ir ed inno v a tio ns
and a ttenti o n to e v en the s m all e st det a il s . W e ar e known a n d r e s p ected for ou r un wa v e r i n g dedication to prod uct design ,
qua l i ty and s e lect ion. U-Line i s hea d quar ter e d in Milwauk e e , Wis c ons i n and h a s s h ipped produ c t to fiv e con t inen ts for o v er
two decades and is prou d to ha v e the opportun ity to s h ip to y o u.
PR ODU C T INFORMA T ION
L ooking for additional inform ation on y o ur p r od uc t? Us er Gu id es , S p ec Shee ts , CAD Draw ings , Compliance Document ation,
a n d Pr oduc t W a r r a n t y in for m a t i o n ar e al l a v ai la bl e f o r r e f e r e n c e an d down l o ad at u-l i ne . c om .
PR OPER TY D A MA GE / INJUR Y CONCERNS
In the unlik e l y e v ent property dam a ge or pers onal injury is s u s p ected r e la ted to a U-Line produc t, plea se t a k e the fol l owi n g
st eps :
1. U-Li ne Cust omer C a r e mus t be c o n tac ted i mmedi a t el y a t +1 .4 1 4 . 3 5 4 . 0 30 0.
2 . Serv i c e or r e p a i r s per f orm e d on th e u n i t w i t h ou t pri o r w r it t e n app r o v a l f r om U - L i n e is n o t perm it ted . If th e u n i t ha s been
alter e d or r e pair ed in th e field withou t pr ior written a p prov a l from U-Line , c l ai ms w i ll not be eligibl e .
G E N E RAL I N QU IR IE S
U-Li ne Corpora t i o n
89 00 N. 5 5th St r eet
Mil w auk e e, Wi sc ons i n 5 3 2 23 USA
Monda y - F r i d a y 8 : 0 0 am to 4:30 pm UT C/GMT - 5
T : +1. 4 1 4 .3 54 .0 300
F : +1. 4 14 .3 54 . 7 9 0 5
Ema i l: s a l e s@ u- li ne . c om
u- li ne . c om
SER V ICE & P A R T S A SSIST ANCE
Monda y - F r i d a y 8:0 0 a m to 4:30 pm UT C / GMT - 5
T : +1.4 14 .3 54 .03 0 0
F : +1. 4 1 4 . 354 .5 69 6
Ser v i c e Emai l: on li nes e rvic e@u - line . c om
P a rt s Ema i l: onli nep a rt s@ u- li ne . c om
CONNEC T WITH US
Designed, engineer ed an d ass e mbled in WI, US A
Intr od uc ti on 1
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Safety and Warning
PLE A SE READ all inst ructions before inst alling,
operating, or serv icing the appliance.
SA FETY ALERT DEFINITIONS
Throughout this gui d e are s a f e ty it ems la beled wi th a
Dan g er, Warni ng or C a u t i o n based on the ris k type:
DANGER
!
Danger means that fai l ure to fol l ow this safet y
stat ement will result in se ve re per son al inj u ry o r
death .
WARNING
!
Th is appliance is not in ten d ed for u s e by per s ons
(inc ludi ng c h i l dr en) wi th r e duced phys ic al , s e nsory or
men t al capabilities , or lack of exp e rie n ce or knowledg e,
u n l e ss th ey ha ve been giv e n su per v is io n o r in st ru ct ion
con c er ni ng us e of th e appli a nc e by a per s on res p ons i b l e
for th eir s a fety. C h i l d r en sh ou ld be s u per v ised to en su re
that t h ey do not pl ay wi th this a p pl ia nc e.
DANGER
!
This uni t contains R600a (Isobut ane) which is a
flam mab l e hydro c arbon . I t is safe for regular
use. Do n o t us e sharp objects to expedite
defr osting. D o not ser v ice wi thout consul ting the
“R 6 0 0 a sp ec i f ic a t i o ns” s e c t io n in c l u d e d in th e
U s er Guide. D o not damage the r e f r iger ant
circuit.
DANGER
!
Warning means that fa ilure to fol l ow this safet y
statement cou l d resu lt in seriou s pers onal injury
or d e ath.
CAUTION
!
Ca ut io n mea n s t h at fail ur e t o follow this saf e ty
statement may result in minor or mod e rate
pe rs onal in ju ry , p r ope r ty or eq uipm en t dam a ge.
GENERAL PRECAUTIONS
U s e th is a ppl ia nc e f o r it s in ten d ed purp ose onl y an d f o l l ow
these g e neral p r ecaution s with thos e li sted th roug hout th is
gu ide.
D o n o t u s e e l ectrical ap plian c es inside th e food
storag e compartment of th is app l ian c e.
WARNING
!
Keep v e ntil ation openings i n the appliance
enclosure or in the built in structure cl ear of
obs t ructio n.
WARNING
!
Do n o t s t ore explosive subs tances such as
aerosol cans with flammab l e propellant in th is
appliance.
WARNING
!
Requirement f o r an external switch in t h e fix e d
wiri ng is spec ified.
Safet y and Warnin g 1
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Thi s appli a nce is intended to b e us ed i n hou s eh old an d
CAUTION
!
similar applicat ion s su ch a s :
Us e care when moving an d hand ling th e un it.
Us e gloves to prevent p e r sonal in ju ry from sharp
edges.
If you r mo del requ ires d e frostin g, DO NOT u s e
medical devices or oth e r me a n s to a c c e l e r a te t h e
defrosting p r ocess. DO NO T u s e an ice pick or
other sharp instrument to h e lp speed up
defrosting. These inst ru m e n t s can p uncture the
inner lining or dama ge the cooling unit. DO NOT
use any t y pe of heat er to defros t . Usi n g a heater
to speed up defrostin g can cau s e person a l injury
and damage t o the inner li ni ng.
Do not lift unit by door handle.
Nev e r install or operate th e un it be hi nd cl os e d
doors. Be sure front gr ille (plinth strip/base
fascia ) is f r ee of obstruct ion. Obstruct ing f r ee
airflow can cause th e un it to m a lfu n ction and
will void the warranty.
• S ta ff ki tc hen a r ea s in s h ops , office and other working
environments.
• F arm hous es and b y c l i e nts i n h o tels , motels and other
res i den t ial type envir o nmen ts .
• B ed and breakfas t ty pe env i ronments .
• C ateri n g and si mi lar non - retai l applic ati o ns.
Fai l ure to cle a n the condenser ev er y si x months
can cause th e un it to m a lfu n ction. Th is co uld
v o id th e wa r r a n ty .
All o w unit tem p era t ure to stabili ze for 24 hours
before use.
Do not bl oc k any inter n al fans.
Us e only g e nu ine U - Line re placem en t par t s.
Im itation parts can dam a ge the unit, af fect it s
operation or p e rformance an d may void the
warran ty.
Safet y and Warnin g 2
USER GUIDE
u- li n e . c om
SA FETY • I NSTALLATION & INTE GRATION • OPER ATI NG INS TRUCTIONS • MAINTENANCE • SE RVICE
Disposal and Recycling
DANGER
!
RISK OF CH ILD ENTRAPMENT. Bef o r e you throw
away your old ref r igerator or freezer, take off
the d oors an d leave shelves in place so children
may not easily cli m b inside.
If the unit is being remov e d from s e rv ic e for di spos al,
check and obey a ll federal, sta t e a n d l o ca l regul ati ons
reg a rd in g the di sp os al an d recy cl i n g of r e fr ig erat i o n
appliances, and follow these steps com p letely:
1. Remove a ll consumable contents from the unit.
2. Unplug the elec tric al c o rd f r o m its s o cket.
3 . Remov e th e d o or (s )/ dra w er (s ).
Dis p osal and Re c y cli n g 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Environmental Requirements
Th is m o del is in ten d ed f o r in door/i nt eri o r ap pl ic at ion s onl y
and i s not to be us ed i n inst all ati ons t h a t are open/
exposed to natural elements.
Thi s un it is des i gn ed to op era t e betw een 5 0 ° F ( 1 0°C ) and
9 0 °F (3 2° C) . H i g h er am bien t temper a tures may redu ce
th e un it ’s abil ity to rea c h lo w temperatures and/or redu ce
ice produ c tion on applicable mod e ls .
Fo r best perform a nce, keep the unit out of direct sunlig ht
and a w ay from heat generat i ng equi pment.
I n cl im at es w h ere h i gh h u m i di ty an d d e w poi n t s ar e
pres ent , c o nden sa ti on ma y ap pear on ou ts ide s urf ac es.
Thi s is c o ns ider ed n o rmal . T h e condensation wil l
evaporate when th e h u midity d r ops.
CAUTION
!
Damages caused by am bi en t tem p e r atur es of
40 °F (4 °C) or below are not co vered by the
warran ty.
E n v i ronmental Requirements 1
USER GUIDE
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Electrical
El ectrical inst allat i on must observe all sta t e and
WARNING
!
S H O C K HA ZA RD — E l ectr ical Gr oun d ing
Required. Never att e mpt to repair or perform
maint e nance on the unit unt il t h e el ectricit y has
be en d i sconne cted.
Never rem o ve th e round g r ou ndin g pro n g from
the p l u g and never u s e a two-p r on g gro und in g
adapter.
A l te ring , cu tt ing or re mov i ng pow e r cord ,
re mov i ng power pl ug, or di rect wiri ng can cause
serious injury, fire, los s of property and/or lif e,
and wi ll v o id the warranty.
local codes. This unit requires connection to a
gr oun d ed ( t hr ee -pr o ng) , polarized receptacle
that h a s been placed by a qualified el ectrician.
Th e u n it requ ires a grou nd ed and polar i zed 230 VA C,
50 Hz, 8A power su pply (n ormal h o useh old cur r ent). An
individual, proper ly groun d ed branc h ci rc ui t or ci rc ui t
breaker is recommen d ed. A G F CI (grou n d fault cir c u i t
i n terrup ter ) is u s u a lly not r e qui r ed for fi xed location
appliances an d is not recomme nd ed fo r y o ur u n i t b e c a u s e
i t cou l d be pron e to nui sanc e tr ippi ng . H o wever, b e s ure
to c o ns ult you r loc a l codes .
See CUTOUT DIM E NS IONS for r e comm ended receptacle
locat i on.
Nev e r use an extension cor d to connect power to
the unit .
A l ways k e e p you r wo rk in g are a d r y .
If the det a c h a b l e ty pe elec tric su pply cor d is damaged, it
mu st b e r e pl ac ed b y an equi va lent cord a vai la bl e from the
manu factur er or i t s ser v i c e ag ent .
Electri c al 1
USER GUIDE
4"
(102 mm)
7"
(178 mm)
33-7/8"
(860 mm)
to
34-7/8"
(886 mm)
23-3/4"
(605 mm)
Preferred location
for electrical outlet
is in adjacent
cabinet.
24"
(610 mm)
5/8"
(16 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Cutout Dimensions
PREP AR E SITE
Y o ur U - Lin e p r od uc t h a s b een designed ex clusiv ely for a
bu il t - i n in st a l la ti on. Whe n bui l t - in , y o ur u n i t does n o t
r e quir e addit i onal ai r spa c e f o r top , si des , or r e a r .
H o we v e r , the fr ont g r i l le (pli nth stri p/base fas c i a ) m u s t
NO T be obs t r u c t ed.
Th e pr oduct is designed and manu factur ed for seamless
in tegr at ion i n th e spec if ied c u t o ut openi n g sh own , w h i c h
r e quir es pr ecise measurem en ts . T h e opening must be
sq uar e and plumb front to back . Alth ough n o t r e quir ed,
y o u ma y ch oos e to in cr ea se the o v erall cutout width for
eas e of ins t all ati on.
The Modula r 30 00 Seri es un its ar e engineer ed w i th a
v a ri ety of a d jus t ment f e a t ur es to hel p ens u r e a sea m l e ss
ins t all ati on. Adjus t able doors , le v e ling legs and gri lle wi ll
assi st in fi ne tu ni ng th e ins t allati on.
CUT O UT DI MENSIONS
Me tr i c m e as u r em e n ts ro u n d e d an d o p ti m i z e d .
Al l 3 0 0 0 Se r i e s m o de ls fu ll y integrate into o v erla y/f a ce
fram e , in set or Eu ropean/frameless cabin e t styles .
CAUTION
!
Un it c a n N O T be i n s t a l le d beh i nd a closed cab i net
door .
Cuto ut Dimensio ns 1
USER GUIDE
(856 mm to 881 mm)
23 5/8" (600 mm)
*Includes 3/4" (20 mm) integrated panel
3-5/8" to 4 5/8"
(92 to 118 mm)
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Product Dimensions
Product Dimensio ns 1
USER GUIDE
Left Hinged C abinet
Right Hinged C abinet
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
Anti-Tip Bracket
CAUTION
!
The ant i -tip brac ket must be in s t all e d to pr ev en t
the unit from ti pping w h en doors are fully
opened or excess w e igh t is placed on the front of
the unit .
The anti -t ip brac ket has mu lt ip le mou n t i n g opti ons .
Mou n ting will depen d on your partic ular cabin e t
c o nf igurat ion. L o ca te 3 #8x 5 /8 " sc rew s inc l uded wi th your
un it.
TOP MOUN T
SID E MOU N T
Si de moun t pos i tion i s us ed wh en you are un ab le to m o unt
the brac ket t o the unders i de of your c o untertop.
Fo r ea se of i n s t a lla tion, the an ti- t ip brack e t is pre- in stalled
in th e top moun t pos i tion .
1. Completely slide the unit in t o i t s posi ti on i n th e
cabi net. Be c e rtai n uni t h e igh t i s proper ly adju sted.
(See GENERAL INSTALLATIO N ).
2. Open door completel y. Ma ke c e rtai n door clear s
su rrou n di ng c a bi netry.
3. Us ing a 3 / 32" (2. 5 0 mm) dri ll bit , dri ll 3 pil o t hol e s 5/8"
(1 6 mm) deep into bot t om of counter top. Use the
anti -tip bra c ket a s a t e mpl ate.
4. Ins tal l 3 #8x 5 /8" s c rews into the pla t e usi n g a
#2 Phi l li ps h e ad sc rewdri ver.
1. Remove the pre-i n s t a lled an t i - t i p bra c k e t f r om th e top
mount posi tion a n d ali g n t h e bra c ket to t h e hi nge s i de
of the unit as shown above.
2. Reinst al l t h e 2 #8x 5 /8" s c rews i n t o the pla t e us ing a
#2 P h i l li ps h e ad sc rewdri ver.
3. Completely sl ide the unit in t o i t s posi ti on in th e
cabi net. Be c e rtai n uni t h e igh t i s proper ly adju sted.
(See GENERAL INSTALLATIO N ).
4. Open door completel y. Ma ke c e rtai n door clear s
su rrou n di ng c a bi netry.
5. Us ing a 3 / 32" (2. 5 0 mm) dri ll bit , dri ll 3 pil o t hol e s 5/8"
( 1 6 m m ) deep i n t o c a bin e tr y fr am e u s i n g t h e an ti -t ip
brac ket as a templa t e.
6. Ins tal l 3 #8x 5 /8" s c rews into the pla t e usi n g a #2
P h illip s head s c r e wd river.
Anti -T ip Bra c k e t 1
USER GUIDE
R o t ate Clockwise to raise r ear leg.
R o t ate Counter -Clockwise to lower leg.
R o t ate F ront Legs to Adjust
u- li n e . c om
SA FE TY • INSTALLATION & INTEGRATION • OPERATIN G INSTRU CTI O NS • MAI N TENANC E • SERVIC E
General Installation
1 . U s e a l e vel to con f i r m
the unit is lev e l. Lev e l
sh ould be placed along
top edg e and side ed ge
as s h own.
2. If t h e uni t is not level , remov e gri l l e and adjus t legs as
neces s a r y . Us e i n c l uded t ool to adjus t the height of the
rear leg s .
INSTALLATI ON
1. P l u g in the power/elec t ri cal c o rd.
2. G e nt ly pus h the uni t i n t o pos i ti on. Be c a reful not to
entangle the cord.
3. Re-check the l e veli ng, from front to back and side to
s i de. Ma ke any nec e ss ary adjus t ments . The uni t ’ s top
su rf ac e s h ou ld be a pprox im at ely 1/ 8" ( 3 m m ) bel o w
the c o unt e rt op.
4. Ins tal l t h e anti -t ip brac ket .
5. Remove the i n t e ri or packi n g materi al a n d w i pe out t h e
i n s i de of the unit wit h a clea n, wa ter-da mpened c l oth.
3 . C o nf irm t h e un it is l e v e l af ter ea ch adjust ment and
repeat the previous s t eps unti l t h e unit i s l e vel.
INSTALLA TION TIP
If the room floor is higher than the f l oor i n the cutout
opening, adjust the rear legs t o a c hiev e a tota l unit rear
height of 1 / 8" (3 mm) les s th an the opening’ s rear hei g ht.
Sh or ten the un it hei g ht in th e front by a d just ing the f r ont
legs. This a llows t h e unit to be gen t ly tipped in to the
opening . Adjust the front leg s t o l e vel th e uni t a f t e r it is
cor r ec tl y pos i t i on ed in the opening.
General Insta llat i on 1
USER GUIDE
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE
TO MOUNT OVERLAY PANEL FLAT AND WITHOUT
INTERFERENCE
23-1/2 "
(595 mm)
3/4"
(20 mm)
Integrated P anel
14-15/16"
(379 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Integrated P a nel Dimensions
Metric measu r em ents roun ded an d optimized.
ST AND A RD P A NELS
Due to diff eren ces in su rroun d ing cabinetr y the
pan e l ma y not per f ect l y alig n with draw er . The
procedure below is designed to pro v ide a
finished integrated panel that seamlessly
integrates wi th surrounding cabinetr y .
P a nel Prep aratio n
A f u l l i n t e grat ed drawer panel completel y co v e rs the
dra w er an d p r o v id es a bu il t - i n ap pear an ce .
T w o panels ar e r e qu ir ed per un it. Dim e nsi o ns for both
pa nel s ar e t h e sa me for s t an dar d in tegr at ed pa nel s an d
handleless i n tegr ated pan e ls .
When appl ying an integr ated panel to a unit ,
en sure th at both sid e s are finished in order to
pre v ent warping.
Stand a rd P a n e l Dim e ns io ns
Each draw er panel m u st not weig h more th an
20 lbs (1 0 k g) .
It i s impor t ant t o ensure that a ll dri lled holes are
drilled to the correct de pth in order to a v oid
split s i n the wood when hardware is instal led.
1. Cut the pa nels to the dimens ions listed in the d i agram
below .
2. Opti ona l : St ain or f i nis h pa nel to des i red st a i n or col o r .
Be sur e to closely fol l ow the instructions pro v ided b y
the manufac tur e r .
3. Opti ona l : Ins t a ll ha ndl e s a n d ha rdw a r e .
Integr ated Pa ne l Dimensio ns 1
USER GUIDE
Top Design
and Insert Notch
Wooden Insert
Main Panel
Integrated Panel
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
HA NDLE LESS INT E GR A T ED DRA W E R P A NEL S
The foll owing procedur e is d e si gned to p r o v id e a finishe d ,
handleles s soli d panel for a 24 " ( 6 0 0 mm) draw er that
sea m less ly in teg r a t es wi th i t s sur r oun d in g ca bi net r y .
Prepar e two panel s for y o ur d r awer unit.
NO TE: Ma n y ca bi net manufac tur e rs provi d e a r e ady
s o lution f o r a ha ndlel e ss , in tegrated des i gn that c a n be
eas i l y applied to y o ur U-Li ne 300 0 Seri es model. Cons ul t
y o ur c a b i net manufactur e r for appli c able des i g n an d
ins t all ati on det a il s . The c a bine t ma nufa ct ur er ’ s s o lutio n to
this des i gn and i n t e grat ion det a i l w i ll oft e n r e sult i n a n
integrat ed panel s o luti on wh er ein the siz e of the panel
ma y r e s u lt in a heigh t dime nsi o n t a l l e r than what we
s p ec if y . T h i s ca n b e ac hi e v ed pro v ided the additional
height i s pos i t i oned ab o v e the app l iance drawer .
The integrated panel aligns with th e surround in g
cabinetr y an d, due to diff erences in cabin e tr y ,
m a y not align per f ec t l y with the dr awer .
3. Prepar e the insert (s ) t h a t w i ll bac k up the handl e les s
des i gn . W ood en In ser t – Cu t 1/ 8" th ic k woode n
i n s e rt (s ) t o t h e di me n s io n s be l o w .
W o ode n i n ser t w i d t h W o o de n i n ser t h e ig ht
23-1/2" (59 5 mm) 3 -1/2 " (89 m m)
4. Opti ona l : St ai n or finis h panel and wooden insert to
desi r e d s t ai n or color . Be s u re to clo s ely fo llow the
i n s t r u c t i o ns p r o v id ed by t h e ma nu fa ct urer .
The appliance will need up to 3 4 -1 /2" (8 76 m m )
to the under s ide of the co unter to lea v e room for
le v e ling adj u st ment s .
Each draw er panel w i th inser t must not weigh
more than 20 lbs (10 k g).
Int e grat ed P a nel Preparati o n
1. Cut the mai n pa nel to the dimensi o ns below . F o r
det a il s , see th e d r aw i n gs on th e n e xt p a g e .
Main p a n e l wi dth M ain panel hei g ht
23- 1/2" (59 5 m m ) 1 3 - 13/16" (351 mm )
2. Create the top des i gn for the ha ndl e less f e at ur e and
the 1 / 8" not c h f o r the ins e rt (s ) i n di ca ted on t h e T o p
Det a il dr a w in g.
If fin i s h ing pan e l or wo oden in ser t , all sides
m u s t be fin i s h ed to preve n t wa rp in g.
5. Att a ch the i n s e rt to the panel. W ood glue or equiv a l e nt
a d hes i v e sh oul d b e u s ed t o a ttac h in sert to pa nel .
Integr ated Pa ne l Dimensio ns 2
USER GUIDE
3/4" (20 mm)
13-13/16"
(351 mm)
R 5/8"
(R 16 mm)
1/8" (3 mm)
1/4" (6 mm)
Wooden Insert
Notch Depth: 1/8" (3 mm)
2-3/8"
(60 mm)
7/8" (22 mm)
Ref.
Top Detail
Insert Notch
Top Design
1/8" (3 mm)
3-1/2"
(89 mm)
23-1/2" (595 mm)
Wooden Insert Dimensions
23-1/2"
(595 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Handleless Integra t ed P a nel Dimensions
Integr ated Pa ne l Dimensio ns 3
USER GUIDE
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
EXTENDE D INTEGRA T ED P A NELS
Due to diff eren ces in su rroun d ing cabinetr y the
pan e l ma y not per f ect l y alig n with draw er . The
procedure below is designed to pro v ide a
finished panel that sea m lessl y i n t e grat es with
surround in g cabinetr y .
P a nel Prep aratio n
An ex ten d ed in teg r at ed pa ne l ca n be us ed to ma in t a i n
al ignment wit h an adjac e nt ex tended c a b i net hei g ht or a
r e duced toe- kick/ g rille ap plication .
1. Cut the panels to the dimensi o ns l i s t ed i n the
appropri at e dia g ra m on the next pa ge .
2. Opti ona l : St ain or f i nis h pa nel to des i red st a i n or col o r .
Be sur e to closely fol l ow the instructions pro v ided b y
the manufac tur e r .
3. Opti ona l : Ins t a ll ha ndl e s a n d ha rdw a r e .
Each draw er panel m u st not weig h more th an
20 lbs (1 0 k g) .
It i s impor t ant t o ensure that a ll dri lled holes are
drilled to the correct de pth in order to a v oid
split s i n the wood when hardware is instal led.
Appliance wi ll need up t o 34 -1/2 " (8 76 m m ) to
the under s ide of the count e r to l e a v e r o om for
le v e ling adj u st ment s .
When appl ying an integr ated panel to a unit ,
ensure th at both sid e s are finished in order to
pre v ent warping.
Integr ated Pa ne l Dimensio ns 4
USER GUIDE
3-5/16" (89 mm)
to
4-5/16" (114 mm)
U-Line
Unit
U-Line
Unit
Integrated Panel
Integrated Panel/Integrated Frame
Front Side
Front Side
3-5/16" (89 mm)
to
4-5/16" (114 mm)
Floor
Cabinet
> 3-5/16"
(> 89 mm)
3-5/16" (89 mm)
to
1" (25 mm)**
U-Line
Unit
Extended Integrated Panel/Extended Integrated Fr ame
Floor
Cabinet
3-5/16" (89 mm)
to
1" (25 mm)**
*
U-Line
Unit
Integrated Panel
* P anel can extend be y o nd the
dr awer .
** A minimum of 1" (25 mm ) from
the floor is r e quired for proper
v e nt il ati on.
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Integr ated Pa ne l Dimensio ns 5
USER GUIDE
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE
TO MOUNT OVERLAY PANEL FLAT AND WITHOUT
INTERFERENCE
23-1/2 "
(595 mm)
3/4"
(20 mm)
Integrated P anel
14-15/16"
(379 mm)
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE
TO MOUNT OVERLAY PANEL FLAT AND WITHOUT
INTERFERENCE
23-1/2 "
(595 mm)
3/4"
(20 mm)
Integrated Panel
17-13/16"
to
18-13/16"
(452 mm
to
478 mm)
* A mi ni mu m o f 1" (2 5 mm ) is r e q u ir e d f r o m th e
floor to the bottom of the extended integrated
pan e l/ fr am e for proper v e ntilation .
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Ex tended Integrated P a nel Dimensions
To p D r a w e r
B o ttom Dr a w e r
Integr ated Pa ne l Dimensio ns 6
USER GUIDE
Apply T ape T o Shaded Ar ea
23-3/4"
(605 mm)
20-5/8"
(525 mm)
1-9/16"
(40 mm)
1-9/16"
(40 mm)
1" (25 mm)
3-5/16" to 4-5/16"
(84 mm to 110 mm)
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Integrated Grille - Plinth
Dimensions
PREP AR E AND INS T AL L INTE GRA T ED GRILL E
(PL I NTH ST RIP / BA SE F A SC IA)
1. Us e t h e di mensi o ns pro v ided i n t h e di agram to cut a n d
sh ap e y o u r integr ated gri l le (pli nth stri p/b a s e fas c i a )
panel. R e com m ended panel th ickn ess is between 1/4"
(6 mm) a n d 3/8" (9 mm). Hei g ht wil l v a ry f r om 3 - 5/16 "
(84 m m) to 4-5/16" (110 mm) bas e d on y o ur gr ille
(pli nth stri p/b a s e fas c i a ) hei g ht.
2. Fini sh or s t ain y o u r g r i l le (pli nth stri p/base fas c i a )
panel to matc h y o ur s urrou n di ng fur n i t u r e . Fi ni sh
front, back and edg e s to pr e v ent warping. Car e fu lly
follow the manu factur er ’ s r e comm endations for finish
application and cur e times .
3. Apply dou b le s i d e d tape to the backs i d e of th e
integrat ed gri ll (pli nt h st r i p/ bas e fascia). Us e th e
di ag ram b e low for r e f e r e nce . U- Li ne r e com m ends
3M
™ VH B ™ t a pe , a high s t r e n g th bonding t a pe .
INTE GRA T ED GRIL L E ( P LI NTH S T RI P / BAS E
F A SCIA) DIMENSION S
4. R e mo v e back in g pap e r from d o uble sided t a pe .
5. C a r e fully alig n gri l le (pli nth s t ri p/b a s e fasci a ) o v er
integrated panel an d p r es s in to pos i tion .
Inte gr a t ed G r i l l e - Pl i n th D i m e ns io ns 1
USER GUIDE
u- li n e . c om
SAFE TY • INST ALLA TION & INTEGRA T ION • OPERA T ING IN STR U CTIONS • M A INTENA NCE • SER V IC E
Integrated P a nel Inst allation
1. F u l l y open draw er .
2. Ali g n t o p of pa nel wi th t o p edge of draw er . C e nt er
panel on d r awer .
Due to diff eren ces in floor con s truction or
surround in g cabinetr y , the p a n e l ma y no t sit
flush wi th the top of the dr awer .
3. Secur e integra t ed
panel to drawer
us in g clam ps . A
robu st tape ma y
al so be us ed. U-
Li ne r e com m e nd s
the use of b a r
clamps to secur e
the pa nel to the
drawer . If usi n g
t a pe , be cer t ain th e
ta p e w i l l n o t
damage panel fin i s h
upon r e m o v a l.
6. Us in g a Ph il lips s c r e w d r i v e r , pla c e one sc r e w in to ea ch
of t h e 6 pil o t holes and sc r e w down. Do no t ov ert i ght e n
sc r e ws .
7. R e mo v e clamps fr o m d r awer .
If panel requ ires ad diti onal a d ju stment after
remo ving clamps , slig ht ly loosen each screw and
adjust panel as n e cessar y . Tigh ten screws up on
completion.
4. Us ing a 7/64 "
(3 mm) drill bit, drill
6 pilot holes into
the w ood panel 1 / 2"
(12 m m) deep us in g
the holes in the drawer fram e as a guid e .
It i s impor t ant t o ensure that a ll dri lled holes are
drilled to the correct de pth in order to a v oid
split s in the wood w h en hardwood is installed.
5 . L o ca te 1 2 of t h e #6 x 1- 1/ 2" ( 3 8 m m ) sc r e ws p r o v id ed
wi th y o ur unit .
Integrat ed P a nel Insta llat i on 1