U-Line U3018WCOL01, 3036RRGLOL00 Installation Manual

®

INSTALL GUIDE

MODULAR 3000 SERIES
WINE CAPTAIN®
MODELS
U-3018WCOL-00
U-3018WCOL-01
U-3018WCS-00
U-3018WCS-01
U-3018WCS-13
BEVERAGE
CENTERS
U-3024BEVOL-00
U-3024BEVOL-01
U-3024BEVS-00
U-3024BEVS-01
U-3036BVWCOL-00
GLASS DOOR
REFRIGERATORS
U-3018RGLOL-00
U-3018RGLOL-01
U-3018RGLS-00
U-3018RGLS-01
U-3018RGLS-13
REFRIGERATORS
U-3018RFOL-00
U-3018RFOL-01
U-3018RFS-00
U-3018RFS-01
U-3024RFOL-00
U-3018WCS-15
U-3024WCOL-00
U-3024WCOL-01
U-3024WCS-00
U-3024WCS-01
U-3036WCWCOL-00
THE MODULAR 3000 SERIES ARE INTENDED FOR BUILT IN INSTALLATIONS ONLY
U-3036BVWCS-00
U-3036BVWCS-13
U-3018RGLS-15
U-3024RGLOL-00
U-3024RGLOL-01
U-3024RGLS-00
U-3024RGLS-01
U-3036RRGLOL-00
U-3036RRGLS-00
U-3036RRGLS-13
The American Built-In Undercounter Leader Since 1962
U-3024RFOL-01
U-3024RFS-00
U-3024RFS-01
U-3036RROL-00
U-3036RRS-00
U-LINE.COM
1 Table of Contents
Safety Precautions
Safety Alert Definitions ........................................................................................................................................ 1
General Precautions..............................................................................................................................................1
Inspect & Plan
Product Registration .............................................................................................................................................2
Product Description..............................................................................................................................................2
Exterior Cleaning................................................................................................................................................... 2
Prepare Site
Electrical Specifications.........................................................................................................................................3
Cut-Out Dimensions ............................................................................................................................................3
3018 Series................................................................................................................................................... 3
3024 Series................................................................................................................................................... 3
Product Dimensions
Door Swing Dimensions
3000 Series Doors
3000 Series Overlays
3000 Series Anti-Tip Bracket
Level & Install
3036 Series................................................................................................................................................... 3
3018, 3024 & 3036 Series......................................................................................................................... 4
Other Site Requirements.....................................................................................................................................5
Side-By-Side Installation ............................................................................................................................ 5
Power Supply............................................................................................................................................... 5
Environmental Requirements................................................................................................................... 5
Door Alignment and Adjustment....................................................................................................................... 6
Overlay / Frame Overlay Panel ..........................................................................................................................7
Panel Preparation........................................................................................................................................ 7
Panel Installation ......................................................................................................................................... 8
Overlay Grille .........................................................................................................................................................9
Anti-Tip Brackets Installation............................................................................................................................11
Leveling Information............................................................................................................................................13
Installation..............................................................................................................................................................13
Relocating the Shelves ............................................................................................................................. 13
Installation Troubleshooting................................................................................................................... 13
IMPORTANTIMPORTANT
DANGER
WARNING
CAUTION

2 Safety Precautions

DANGER
WARNING
WARNING
CAUTION
IMPORTANTIMPORTANT
• PLEASE READ all instructions before installing, operating, or servicing the appliance.

General Precautions

Use this appliance for its intended purpose only. The 3000 model series is intended for BUILT IN brackets MUST be installed. Follow these general precautions
with those listed throughout this guide:
installation only. Anti tip
• Proper installation procedures must be followed when completing an installation or relocation of a unit. Consult the installation guide before any installation begins. U-Line contact information appears on the rear cover of this guide.
• This unit requires connection to a dedicated 15 Amp grounded (three-prong), polarized receptacle. Receptacle should be installed by a qualified electrician, compliant with applicable electrical codes.

Safety Alert Definitions

Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type:
Danger means that failure to follow this safety statement will result in severe personal injury or death.
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or freezer, take off the doors and leave shelves in place so children may not easily climb inside.
SHOCK HAZARD - Electrical Grounding Required.
• Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
• Never remove the round grounding prong from the plug and never use a two-prong grounding adaptor.
• Altering, cutting of power cord, removal of power cord, removal of power plug, or direct wiring can cause serious injury, fire and or loss of property and or life, and will void the warranty.
• Never use an extension cord to connect power to the unit.
• Always keep your working area dry.
Install provided Anti-Tip kit on all models. Units may NOT
be installed as free standing. Serious
personal injury could occur.
Warning means that failure to follow this safety statement could result in serious personal injury, property or equipment damage.
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
• Use care when moving and handling the unit. Use gloves to prevent personal injury from sharp edges.
• If your model requires defrosting, DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining.
• Do not lift unit by door handle.
• Never install or operate the unit behind closed doors. Be sure front grille is free of obstruction. Obstructing free airflow can cause the unit to malfunction and will void the warranty.
• Failure to clean the condenser every six months can cause the unit to malfunction. This could void the warranty.
• Allow unit temperature to stabilize for 24 hours before use.
• Do not Block any internal Fans
Use only genuine U-Line replacement parts. Imitation parts can damage the unit, affect its operation or performance and may void the warranty.
U-Line 3000 Series Product Features 1

3 Inspect & Plan

IMPORTANTIMPORTANT
WARNING

Product Registration

You have received a carton containing your 3000 series unit with a package inside containing a Quick Start Guide and a Registration Card. Please complete and mail the Product Registration Card. You may also register the unit online at u-line.com. Go to the Customer Service tab and click on Product Registration. Once your unit is installed, keep the Quick Start Guide in a safe place for future reference

Product Description

This installation guide covers the following models.
U-3018RGLOL-00 U-3024RGLS-00
U-3018RGLOL-01 U-3024RGLS-01
U-3018RGLS-00 U-3024RFOL-00
U-3018RGLS-01 U-3024RFOL-01
U-3018RGLS-13 U-3024RFS-00
U-3018RGLS-15 U-3024RFS-01
U-3018RFOL-00 U-3024WCOL-00
U-3018RFOL-01 U-3024WCOL-01
U-3018RFS-00 U-3024WCS-00
U-3018RFS-01 U-3024WCS-01
U-3018WCOL-00 U-3036RRGLOL-00
U-3018WCOL-01 U-3036RRGLS-00
U-3018WCS-00 U-3036RRGLS-13
U-3018WCS-01 U-3036BVWCOL-00
U-3018WCS-13 U-3036BVWCS-00
U-3018WCS-15 U-3036BVWCS-13
U-3024BEVOL-00 U-3036WCWCOL-00
U-3024BEVOL-01 U-3036WCWCS-00
U-3024BEVS-00 U-3036WCWCS-13
U-3024BEVS-01 U-3036RRS-00
U-3024RGLOL-00 U-3036RROL-00
U-3024RGLOL-01

Exterior Cleaning

Stainless door panels, handles and frames can discolor when exposed to chlorine gas, pool chemicals, salt water or cleaners with bleach.
• Keep your Stainless unit looking new by cleaning with a good
quality all-in-one stainless steel cleaner/polish on a monthly basis. For best results use Claire Stainless Steel Polish and Cleaner, which can be purchased from U-Line Corporation (Part numbers 173348). Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning on a weekly basis.
• Do not clean with steel wool or abrasive pads.
• Do not use cleaners that are not specifically intended
for stainless steel on stainless surfaces (this includes glass, tile and counter cleaners).
• If any surface discolors or rust appears, clean it quickly with
Bon-Ami or Barkeepers Friend Cleanser and a non-abrasive cloth. Always clean in the direction of the grain. Always finish this process with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems.
• Glass surfaces may be cleaned with standard household window
cleaners.
Rust that is allowed to linger can penetrate into the surface of the stainless steel and complete removal of the rust may not be possible.
Inspection
Unwrap and inspect the unit on a flat, level surface capable of supporting its entire weight. If necessary, remove protective film from Stainless Steel models.
2 U-Line Product Features
IMPORTANTIMPORTANT
WARNING
IMPORTANTIMPORTANT

4 Prepare Site

4”
7”
24”
18”
33-5/8”
to
34-7/8”
4"
7"
24"
33-7/8"
to
34-7/8"
23-7/8"
35 11/16"
33-7/8"
to
34-7/8"
7"
24"
4"
Your U-Line product has been designed exclusively for a built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear.
• Unit can NOT be installed behind a closed cabinet door.

Electrical Specifications

SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
• Never use an extension cord to connect power to the unit.
Electrical installation must observe all state and local codes. This unit requires connection to a grounded (three­prong), polarized receptacle that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An individual, properly grounded branch circuit or circuit breaker is recommended. GFCI (ground fault circuit interrupter) is usually not required for fixed location appliances and is not recommended for your unit because a GFCI could be prone to nuisance tripping. However, be sure to consult your local codes.
3024 Series
Follow the cut-out drawing. The 23-7/8" width allows for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.
3036 Series
Follow the cut-out drawing. The 35 11/16" width allows for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.
See “Cut-Out Dimensions” for recommended receptacle location.

Cut-Out Dimensions

3018 Series
Follow the cut-out drawing. The 18" width allows for ease in installation and removal of the unit. 24" is the cabinet depth in most installations.
U-Line Prepare Site 3
Loading...
+ 11 hidden pages