USER GUIDE
RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
1000 Series 1215R 15" Solid Door Refrigerator
Page 2
SAFETY INSTALLATION & INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Intro
Safety
Safety and Warning Disposal
Installation
Environmental Requirements Electrical Cutout Dimensions Product Dimensions Side by Side Installation Anti-Tip Bracket General Installation Integrated Panel Dimensions Integrated Panel Installation
Extended Non-Use
Service
Accessories Troubleshooting Warranty
Grille / Plinth Installation Door Swing Door Stop Door Adjust
Operating Instructions
First Use Control Operation Sabbath Mode Airflow and Product Loading Interior Shelves
Maintenance
Cleaning Cleaning Condenser
Page 3
USER GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Line’s complete product collection includes modular Wine Captain
Crescent Ice Makers, Glass & Solid Door Refrigerators, Drawer Models, Freezers, and Combo® Models.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
®
Models, Beverage Centers, Clear Ice Machines,
PROPERTY DAMAGE / INJURY CONCERNS
In the unlikely event property damage or personal injury is suspected related to a U-Line product, please take the following
steps:
1. U-Line Customer Care must be contacted immediately at +1.800.779.2547.
2. Service or repairs performed on the unit without prior written approval from U-Line is not permitted. If the unit has been
altered or repaired in the field without prior written approval from U-Line, claims will not be eligible.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
U-Line Corporation
8900 N. 55th Street
Milwaukee, Wisconsin 53223 USA
Monday - Friday 8:00 am to 4:30 pm CST
T: +1.414.354.0300
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
SERVICE & PARTS ASSISTANCE
Monday - Friday 8:00 am to 5:30 pm CST
T: +1.800.779.2547
F: +1.414.354.5696
Service Email: onlineservice@u-line.com
Parts Email: onlineparts@u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
Introduction 1
Page 4
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Safety and Warning
Please read all instructions before installing, operating, or servicing the appliance.
Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a Danger, Warning or Caution based on the risk type:
DANGER
!
Danger means that failure to follow this safety statement will result in severe personal injury or death.
DANGER
!
This unit contains R600a (Isobutane) which is a flammable hydrocarbon. It is safe for regular use. Do not use sharp objects to expedite defrosting. Do not service without consulting the “R600a specifications” section included in the User Guide. Do not damage the refrigerant circuit.
WARNING
!
Service must be done by factory authorized service personnel. Any parts shall be replaced with like components. Failure to comply could increase the risk of possible ignition due to incorrect parts or improper service.
WARNING
!
Warning means that failure to follow this safety statement could result in serious personal injury or death.
CAUTION
!
Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property or equipment damage.
Safety and Warning 1
Page 5
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Disposal and Recycling
DANGER
!
RISK OF CHILD ENTRAPMENT. Before you throw
away your old refrigerator or freezer, take off
the doors and leave shelves in place so children
may not easily climb inside.
If the unit is being removed from service for disposal,
check and obey all federal, state and local regulations
regarding the disposal and recycling of refrigeration
appliances, and follow these steps completely:
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Disposal and Recycling 1
Page 6
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Environmental Requirements
This unit is designed to operate between 50°F (10°C) and
100°F (37°C). High ambient temperatures (100°F [37°C]
or higher) may reduce the units ability to reach low
temperatures.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are
present, condensation may appear on outside surfaces.
This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
!
Damages caused by ambient temperatures of
40°F (10°C) or below are not covered by the
warranty.
Environmental Requirements 1
Page 7
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Electrical
WARNING
!
SHOCK HAZARDElectrical Grounding
Required. Never attempt to repair or perform
maintenance on the unit until the electricity has
been disconnected.
Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
Altering, cutting or removing power cord,
removing power plug, or direct wiring can cause
serious injury, fire, loss of property and/or life,
and will void the warranty.
Never use an extension cord to connect power to
the unit.
Always keep your working area dry.
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
that has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. A GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
it could be prone to nuisance tripping. However, be sure
to consult your local codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Electrical 1
Page 8
USER GUIDE
24"
(610 mm)
1-1/2" (38 mm)
15-1/4"
(387 mm)
34-1/4"
(870 mm)
to
35"
(889 mm)
Preferred location for electrical outlet is in adjacent cabinet.
7"
(178 mm)
5/8"
(16 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cutout Dimensions
PREPARE SITE
Your U-Line product has been designed for either free-
standing or built-in installation. When built-in, your unit
does not require additional air space for top, sides, or
rear. However, the front grille must NOT be obstructed,
and clearance is required for an electrical connection in
the rear.
CAUTION
!
Unit can NOT be installed behind a closed cabinet
door.
CUTOUT DIMENSIONS
Cutout Dimensions 1
Page 9
USER GUIDE
23-1/4
" (591 mm)
(Includes
3/4
" [20 mm] Integrated Panel)
34-1/8" to 35-1/8"
(867 mm to 892 mm)
14-15/16" (379 mm)
3-9/16" (91 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Product Dimensions
Product Dimensions 1
Page 10
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the cutout
dimension of a single unit times two.
No trim kit is required. However, 1/4" (6 mm) of space
needs to be maintained between the units to ensure
unobstructed door swing.
Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
electrical specifications requirements.
Side-by-Side Installation with Bracket
1. Slide both units out so screws on top of units are easily
accessible.
3. Place bracket over holes and attach to unit with two
screws removed in step 2 using a T-25 Torx driver.
Tighten screws fully.
4. Gently push units into position. Be careful not to
entangle the electrical cord or water line, if applicable.
5. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The units top
surface should be approximately 1/8" (3 mm) below
the countertop.
2. Remove screws as shown below.
Side-by-Side Installation 1
Page 11
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Anti-Tip Bracket
1. Slide unit out so screws on top of unit are easily
accessible.
2. Remove the two screws from the opposite side of the
hinge assembly using a T-25 Torx driver (see below).
NOTE: 1224 models shown with four screw. 1215 models
only have three screws, but same screws are used in both
applications.
3. Place bracket (part #14154) over holes and attach to
unit with two screws removed in step 2 using a T-25
Torx driver. Tighten screws fully.
4. Gently push unit into position. Be careful not to
entangle the electrical cord or water line, if applicable.
5. Check to be sure the unit is level from front to back
and side to side. Make any necessary adjustments.
The units top surface should be approximately 1/8"
(3 mm) below the countertop.
6. Secure bracket into adjoining surface.
Anti-Tip Bracket 1
Page 12
USER GUIDE
1
2
Turn to Adjust
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
General Installation
LEVELING INFORMATION
1. Use a level to confirm
the unit is level. Level
should be placed along
top edge and side edge
as shown.
2. If the unit is not level, adjust the legs on the corners of
the unit as necessary.
INSTALLATION
1. Plug in the power/electrical cord.
2. Gently push the unit into position. Be careful not to
entangle the power cord.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The units top
surface should be approximately 1/8" (3 mm) below
the countertop.
4. Remove the interior packing material and wipe out the
inside of the unit with a clean, water-dampened cloth.
3. Confirm the unit is level after each adjustment and
repeat the previous steps until the unit is level.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the opening’s rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Readjust the front legs to level the unit after it is
correctly positioned in the opening.
General Installation 1
Page 13
USER GUIDE
NOTICE
BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY PANEL FLAT AND WITHOUT INTERFERENCE
3/4" (20 mm)
Integrated Panel
14-3/4"
(375 mm)
30-1/4" (768 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Integrated Panel Dimensions
INTEGRATED PANEL
Due to differences in surrounding cabinetry the
panel may not perfectly align with door. The
procedure below is designed to provide a
finished integrated panel that seamlessly
integrates with surrounding cabinetry.
The door panel must not weigh more than 20 lbs
(10 kg).
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardware is installed.
When applying an integrated panel to a unit,
ensure that both sides are finished in order to
prevent warping. In some panel installations,
the panel may be visible through the glass while
the door is open.
Integrated Panel Dimensions
A full integrated door panel completely covers the door
frame and provides a built-in appearance.
Integrated Panel Preparation
1. Cut the panels to the dimensions listed in the diagram
below.
2. Optional: Stain or Finish panel to desired stain or color.
Be sure to closely follow the instructions provided by
the manufacturer.
3. Optional: Install handles and hardware.
Integrated Panel Dimensions 1
Page 14
USER GUIDE
NOTICE
NOTICE
Align Panel
Against
Door/Drawer
Edge First
Align Top Of Panel With Highest Point Of Door/Drawer
Door
Panel
Integrated Panel
Integrated Panel
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Integrated Panel Installation
1. Fully open door/drawer.
2. Starting at corner, pull
gasket away from door/
drawer.
3. Continue to pull gasket
free from gasket channel.
4. Upon removal, lay gasket down on a flat surface.
5. The panel should be aligned with the outside edge
(opposite the hinge) and high enough to align with the
highest point in the door/drawer.
6. Secure integrated
panel to door/drawer
Bar
Clamp
using clamps. A
robust tape may also
be used. U-Line
recommends the use
of bar clamps to
Door/Drawer
secure the panel to
the door/drawer. If
using tape, be
Wood Panel
certain the tape will
not damage panel
finish upon removal.
7. Using a 7/64" (3 mm)
Bar
Clamp
drill bit, drill 6 pilot
holes into the wood
panel 1/2" (12 mm)
deep using the holes in the door/drawer frame as a
guide.
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
flush with the top of the door/drawer.
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
8. Locate 6 of the #6x 1-1/4" (32 mm) screws provided
with your unit.
9. Using a Phillips screwdriver, place one screw into each
of the 6 pilot holes and screw down. Do not overtighten
screws.
10.Be sure the screws force their way past the opening on
the gasket channel and sit flush against the bottom of
the channel.
Integrated Panel Installation 1
Page 15
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
11.Remove clamps from door/drawer.
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
completion.
12.Starting at the corners, re-install the gasket into the
gasket channel in the frame. Make sure the gasket is
fully seated. This may take some force.
Integrated Panel Installation 2
Page 16
USER GUIDE
2
1
3
5
4
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Grille - Plinth Installation
REMOVING AND INSTALLING GRILLE
WARNING
!
Disconnect electric power to the unit before
removing the grille.
WARNING
!
DO NOT touch the condenser fins (4). The
condenser fins are SHARP and can be easily
damaged.
Removing the grille
1. Disconnect power to the unit.
2. Loosen the two screws (1).
3. Remove grille (2) and grille cap (3) from unit.
Installing the grille
1. Make sure grille cap (3) is behind grille in slots (2)
provided in grille before attaching grille to unit.
2. Align cabinet and grille holes and secure, but do not
over tighten grille screws (1).
3. Reconnect power to the unit.
Grille - Plinth Installation 1
Page 17
USER GUIDE
Wall Wall
90
Door Swing
90
Door Swing
2-1/8" Min.
(54 mm)
1/4" Min.
(6 mm)
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Swing
Units have a zero clearance for the door to open 90°,
when installed adjacent to cabinets.
Stainless Steel and black and white models require 2-1/8"
(54 mm) door clearance to accommodate the handle if
installed next to a wall.
Integrated models require 1/4" (6 mm) clearance if
installed next to a wall. Allow for additional space for any
knobs or pulls installed on the integrated panel/frame.
Door Swing 1
Page 18
USER GUIDE
NOTICE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Stop
Your U-Line unit was shipped to you with the optional
90° pin(s). (Models that are 15" wide include 1 pin. Models
that are 24" wide include 2 pins.) The unit’s door will open
freely without a fixed opening angle limitation. If you
would like the door stop at 90° follow these instructions.
The pin is designed to stop the door at 90° under
normal operating conditions. It is not designed
for excessive force. Do not use the door to move
the unit in/out of the cutout during installation.
If your unit is already undercounter, it might
need to be moved out/forward to access the
hinge.
1. Locate the threaded pin.
3. On 24" models, a second pin is included for the bottom
hinge. Repeat steps above for second hinge.
NOTE: Threaded pin will be inserted from the bottom.
4. Carefully slide your unit back in place.
2. With the door between 0° (closed) and 90° and using a
3/32" hex driver, install the threaded pin through the
hinge.
The pin can be removed to return the door swing
back to its original state by unscrewing the
threaded pin.
Door Stop 1
Page 19
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing
properly. If the door is not sealed, the unit may not cool
properly, or excessive frost may form in the interior.
Properly aligned, the door’s gasket should be
firmly in contact with the cabinet all the way
around the door (no gaps). Carefully examine
the door’s gasket to ensure that it is firmly in
contact with the cabinet. Also make sure the
door gasket is not pinched on the hinge side of
the door.
To align and adjust the door:
1. Loosen (do not remove) top and bottom hinge screws.
TO REVERSE THE DOOR
Remove grille:
Remove the grille (see GRILLE-PLINTH INSTALLATION
section of this guide).
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all
the way around the door (no gaps).
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
REVERSING THE DOOR
Location of the unit may make it desirable to mount the
door on the opposite side of the cabinet.
The hinge hardware will be removed and reinstalled on the
opposite side of the cabinet.
Remove top hinge and door:
1. Hold door to keep it from falling.
2. Remove top hinge from cabinet by removing three
screws.
Door Adjustments 1
Page 20
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
3. Remove door by tilting forward and lifting door off
bottom hinge. Retain shoulder washer; it will be
reused.
4. Remove four screws from hinge holes on the opposite
side. Reinstall into holes where the hinge was
removed. Take care not to scratch cabinet.
Remove bottom hinge:
1. Remove bottom hinge from cabinet.
Install top hinge and door:
1. Reinstall the screws.
2. Hold door to keep it from falling.
3. Lift the door on to the bottom hinge.
4. Align flat edge of the hinge with the outer edge of the
unit.
2. Remove corresponding screws on opposite side of
cabinet. On some models there may be a nut behind
one or both screws on either side.
Install bottom hinge:
Install two or three screws, depending on model. Replace
nuts if used.
5. Tighten three screws.
Align and adjust the door:
Align and adjust the door (see DOOR ALIGNMENT AND
ADJUSTMENT).
Install grille:
Install the grille.
Prepare door for reinstallation:
Rotate door 180° to reverse.
Door Adjustments 2
Page 21
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
First Use
All U-Line controls are preset at the factory. Initial startup
requires no adjustments.
U-Line recommends allowing the unit to run
overnight before loading with product.
When plugged in, the unit will begin operating under the
factory default settings. If the unit was turned off during
installation, simply press and the unit will immediately
switch on. To turn the unit off, press .
First Use 1
Page 22
USER GUIDE
Up Down Light Power
Not
Used
Alert
LED
and
or
and
and
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Control Operation
CONTROL FUNCTION GUIDE
FUNCTION COMMAND DISPLAY/OPTIONS
ON/OFF Press and release Unit will immediately turn ON or OFF.
Toggle lights
Adjust refrigerator set
point
View temperature in unit Press together and release
Toggle between F/C Hold for five seconds The display will change units.
Press and release to leave interior
light on for 3 hours
Press and release
Glass door wine and beverage centers only.
When the “F” or “C” in the display is flashing, press
to adjust the set point temperature.
The display will flash and then toggle from set point
to temperature in unit.
Control Operation 1
Page 23
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
L
Sabbath Mode
12 3 456
This unit is Star-K certified and offers a Sabbath mode.
Sabbath mode disables system responses to user initiated
activities and all external functions; including lighting,
display and audible alarms. The unit will still maintain
internal temperatures and set points. View a full list of
Star-K certified U-Line units at www.star-k.org.
To enable Sabbath Mode.
1. Press (4) and hold for ten seconds and release (the
°F/°C symbol will flash briefly at the end of the ten
second period).
2. The interior light and control display (3) will go dark
until user resets mode.
3. NOTE: Although the display will not be visible, the
temperature controls in the unit remain active, and
preserve the interior temperature.
Sabbath Mode remains active until (4) is quickly
pressed and released.
Sabbath Mode 1
Page 24
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Airflow and Product Loading
The unit requires proper airflow to perform at its
highest efficiency. Do not block the front grille,
or the unit will not perform as expected. Do not
install the unit behind a door. When loading your
unit, leave space between the evaporator and
product loaded. Anything in direct contact with
the evaporator is subject to freezing.
When properly loaded, your U-Line unit will store up to 92
(12 oz. [330 ml]) cans or 57 (12 oz. [330 ml]) bottles.
Airflow and Product Loading 1
Page 25
USER GUIDE
NOTICE
2
3
1
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE • SERVICE
Interior Shelves
REMOVING AND INSTALLING INTERIOR SHELVES
Make sure the shelves are inserted fully into the
unit.
The edge strip toward the rear prevents cans
and bottles from freezing against the cold
evaporator.
For models equipped with glass shelves having recessed
shelf supports, remove the shelves as follows:
1. Pull shelf out about 6" (1), until back of shelf clears the
“hump” on the right-hand side.
2. Tilt up right-hand edge of shelf (2).
3. Remove shelf from unit by pulling out (3).
Insert the shelves as follows:
1. To move to a different position in the unit, insert shelf
at an angle, approximately 15-20°, over the rib in the
side of the unit where you want to place the shelf.
Place the shelf into the unit at an angle to clear the
door.
2. Continue to slide the shelf into the unit at an angle
until it clears the door.
Lower the shelf and push it in completely. E
raised edge strip is toward the rear of the unit.
nsure the
Interior Shelves 1
Page 26
USER GUIDE
u-line.com
SAFETY • INSTALLATION & INTEGRATIONOPERATING INSTRUCTIONS • MAINTENANCESERVICE
Cleaning
EXTERIOR CLEANING
Vinyl Clad (Black or White)
Clean surfaces with a mild detergent and warm water
solution. Do not use solvent-based or abrasive cleaners.
Use a soft sponge and rinse with clean water. Wipe with a
soft, clean towel to prevent water spotting.
Clean any glass surfaces with a non-chlorine glass
cleaner.
Stainless Models
Stainless door panels, handles and frames can discolor
when exposed to chlorine gas, pool chemicals, saltwater
or cleaners with bleach.
Keep your stainless unit looking new by cleaning with a
good quality all-in-one stainless steel cleaner and polish
monthly. For best results use Claire
Polish and Cleaner, which can be purchased from U-Line
Corporation (Part Number 173348). Comparable products
are acceptable. Frequent cleaning will remove surface
contamination that could lead to rust. Some installations
may require cleaning weekly.
®
Stainless Steel
If any surface discoloring or rusting appears, clean it
quickly with Bon-Ami
and a nonabrasive cloth. Always clean with the grain.
Always finish with Claire
Cleaner or comparable product to prevent further
problems.
Using abrasive pads such as Scotchbrite™ will cause the graining in the stainless steel to become blurred.
Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible.
Integrated Models
To clean integrated panels, use household cleaner per the
cabinet manufacturer’s recommendation.
INTERIOR CLEANING
Disconnect power to the unit.
Clean the interior and all removed components using a
mild nonabrasive detergent and warm water solution
applied with a soft sponge or non-abrasive cloth.
®
or Barkeepers Friend Cleanser®
®
Stainless Steel Polish and
Do not clean with steel wool pads.
Do not use stainless steel cleaners polishes on any glass surfaces.
Clean any glass surfaces with a non-chlorine glass
cleaner.
Do not use cleaners not specifically intended for stainless steel on stainless surfaces (this includes glass, tile and counter cleaners).
Rinse the interior using a soft sponge and clean water.
Do not use any solvent-based or abrasive
cleaners. These types of cleaners may transfer taste to
the interior products and damage or discolor the interior.
DEFROSTING
Under normal conditions this unit does not require manual
defrosting. Minor frost on the rear wall or visible through
the evaporator plate vents is normal and will melt during
each off cycle.
If there is excessive build-up of 1/4" (6 mm) or more,
manually defrost the unit.
Ensure the door is closing and sealing properly.
Cleaning 1
Page 27
USER GUIDE
NOTICE
u-line.com
SAFETY • INSTALLATION & INTEGRATIONOPERATING INSTRUCTIONS • MAINTENANCESERVICE
High ambient temperature and excessive humidity can
also produce frost.
CAUTION
!
DO NOT use an ice pick or other sharp
instrument to help speed up defrosting. These
instruments can puncture the inner lining or
damage the cooling unit. DO NOT use any type of
heater to defrost. Using a heater to speed up
defrosting can cause personal injury and
damage to the inner lining.
The drain pan was not designed to capture the
water created when manually defrosting. To
prevent water from overflowing the drain pan,
place towels or other absorbent materials over
the interior drain trough (under the evaporator)
before defrosting.
To defrost:
1. Disconnect power to the unit.
2. Remove all products from the interior.
3. Prop the door in an open position (2 in. [50 mm]
minimum).
4. Allow the frost to melt naturally.
5. After the frost melts completely clean the interior and
all removed components. (See INTERIOR CLEANING).
6. When the interior is dry, reconnect power and turn unit
on.
Cleaning 2
Page 28
USER GUIDE
NOTICE
Condenser
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Cleaning Condenser
INTERVAL - EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille
free of dust and lint, and clean the condenser when
necessary. Depending on environmental conditions, more
or less frequent cleaning may be necessary.
WARNING
!
Disconnect electric power to the unit before
cleaning the condenser.
WARNING
!
DO NOT touch the condenser fins. The condenser
fins are SHARP and can be easily damaged.
DO NOT use any type of cleaner on the
condenser unit.
1. Remove the grille. (See GRILLE-PLINTH
INSTALLATION).
2. Clean the condenser coil using a using a soft brush
with a “combing” action or vacuum cleaner. Do not
touch the condenser coil.
3. Install the grille.
Cleaning Condenser 1
Page 29
USER GUIDE
NOTICE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
Extended Non-Use
STORAGE, VACATION AND MOVING
If not using the unit for an extended period, or otherwise
stored, follow these steps completely:
WARNING
!
Electrical Shock Hazard. Disconnect power
before servicing. Before operating, replace all
panels. Failure to do so may result in electrical
shock or death.
If the ambient temperature is expected to drop
below 50°F (10°C), turn off and unplug unit.
1. Remove all consumable content from the unit.
5. During periods of non-use, the cabinet must remain
open to prevent formation of mold and mildew. Open
door a minimum of 2 in. (5 cm) to provide the
necessary ventilation.
2. Disconnect the power cord from its outlet, and leave it
disconnected until the unit is returned to service.
3. If ice is on the evaporator, allow ice to thaw naturally.
CAUTION
!
DO NOT use an ice pick or other sharp
instrument to help speed up defrosting. These
instruments can puncture the inner lining or
damage the cooling unit. DO NOT use any type of
heater to defrost. Using a heater to speed up
defrosting can cause personal injury and
damage to the inner lining.
4. Clean and dry the interior of the cabinet. Ensure all
water has been removed from the unit.
Extended Non-Use 1
Page 30
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Accessories
80-51004-00
Accessories - Anti-Tip
Mounting Brackets
US$18.99
23054-01
Accessories - Stainless Steel
PRO Style Door Handle,
1-1/4" in diameter
US$49.00
Accessories 1
Page 31
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Troubleshooting
BEFORE CALLING FOR SERVICE
If you think your U-Line product is malfunctioning, read
the CONTROL OPERATION section to clearly understand
the function of the control.
If the problem persists, read the NORMAL OPERATING
SOUNDS and TROUBLESHOOTING GUIDE sections below
to help you quickly identify common problems and
possible causes and remedies. Most often, this will resolve
the problem without the need to call for service.
IF SERVICE IS REQUIRED
If you do not understand a troubleshooting remedy, or
your product needs service, contact U-Line Corporation
directly at +1.800.779.2547.
When you call, you will need your product Model and
Serial Numbers. This information appears on the Model
and Serial number plate located on the upper right or rear
wall of the interior of your product.
NORMAL OPERATING SOUNDS
All models incorporate rigid foam insulated cabinets to
provide high thermal efficiency and maximum sound
reduction for its internal working components. Despite this
technology, your model may make sounds that are
unfamiliar.
Normal operating sounds may be more noticeable because
of the unit’s environment. Hard surfaces such as cabinets,
wood, vinyl or tiled floors and paneled walls have a
tendency to reflect normal appliance operating noises.
Listed below are common refrigeration components with a
brief description of the normal operating sounds they
make. NOTE: Your product may not contain all the
components listed.
Compressor: The compressor makes a hum or pulsing
sound that may be heard when it operates.
Evaporator: Refrigerant flowing through an evaporator
may sound like boiling liquid.
Condenser Fan: Air moving through a condenser may
be heard.
Automatic Defrost Drain Pan: Water may be heard
dripping or running into the drain pan when the unit is
in the defrost cycle.
TROUBLESHOOTING GUIDE
DANGER
!
ELECTROCUTION HAZARD. Never attempt to
repair or perform maintenance on the unit
before disconnecting the main electrical power.
Troubleshooting - What to check when problems occur:
Problem Possible Cause and Remedy
Digital Display and Light Do Not Work.
Interior Light Does Not Illuminate.
Light Remains on When Door Is Closed.
Unit Develops Frost on Internal Surfaces.
Unit Develops Condensation on External Surfaces.
Digital Display Functions, But Unit Does Not Cool.
Digital Display Shows ER or E Followed by a Number.
Ensure power is connected to the unit. If the unit is cooling, it may be in Sabbath
mode.
If the unit is cooling, it may be in Sabbath mode.
For glass door models, press the light icon and close the door.
Check light actuator under door.
Frost on the rear wall is normal and will melt during each off cycle.
If there is excessive build-up of 1/4" or more, manually defrost the unit.
Ensure the door is closing and sealing properly.
High ambient temperature and excessive humidity can also produce frost.
The unit is exposed to excessive humidity. Moisture will dissipate as humidity levels decrease.
Ensure the unit is not in “Showroom Mode.” Momentarily unplug or interrupt power
supply to the unit.
E3 indicates the door may be opened too long. Ensure the door is closing properly. For other error codes contact U-Line Customer Service.
Troubleshooting 1
Page 32
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Problem Possible Cause and Remedy
Product Is Freezing.
Product Is Not Cold Enough.
Because product in contact with the rear wall may freeze, ensure no product is touching the rear wall.
Adjust the temperature to a warmer set point.
Air temperature does not indicate product temperature. See CHECKING PRODUCT TEMPERATURE below.
Adjust the temperature to a cooler set point. Ensure unit is not located in excessive
ambient temperatures or in direct sunlight. Ensure the door is closing and sealing
properly. Ensure the interior light has not remained on
too long. Ensure nothing is blocking the front grille,
found at the bottom of the unit. Ensure the condenser coil is clean and free of
any dirt or lint build-up.
CHECKING PRODUCT TEMPERATURE
6. After 24 hours, check the temperature of the water. If
required, adjust the temperature control in a small
increment (see CONTROL OPERATION).
Causes which affect the internal temperatures of the cabinet include:
Temperature setting.
Ambient temperature where installed.
Installation in direct sunlight or near a heat source.
The number of door openings and the time the door is
open.
The time the internal light is illuminated. (This mainly
affects product on the top rack or shelf.)
Obstruction of front grille or condenser.
To check the actual product temperature in the unit:
1. Partially fill a plastic (nonbreakable) bottle with water.
2. Insert an accurate thermometer.
3. Tighten the bottle cap securely.
4. Place the bottle in the desired area for 24 hours.
5. Avoid opening the unit during the testing period.
Troubleshooting 2
Page 33
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
Warranty
U-LINE CORPORATION LIMITED WARRANTY
1. U-Line Corporation (“U-Line”) warrants each U-Line
product to be free from defects in materials and
workmanship for a period of one year (two years on
Modular 3000 Series) from the date of purchase.
U-Line further warrants the sealed system (consisting
of the compressor, condenser, evaporator, hot gas
bypass valve, dryer, and connecting tube) in each
U-Line product to be free from defects in materials and
workmanship for a period of five years from the date of
purchase.
2. During the initial one year warranty period (two years
on Modular 3000 Series) for all U-Line products U-Line
shall: (1) repair any product or replace any part of a
product; and (2) for all Marine, RV and Domestic
U-Line products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line
shall be responsible for the labor costs performed by a
U-Line authorized service company, incurred in
connection with the replacement of any defective part.
During years two through five of the warranty period
for the sealed system, U-Line shall: (1) at U-Line’s
option repair or replace any part of the sealed system;
and (2) for all Marine, RV and Domestic U-Line
products sold and serviced in the United States
(including Alaska and Hawaii) and Canada, U-Line shall
be responsible for the labor costs incurred in
connection with the replacement of any defective part
of the sealed system. All other charges, including
transportation charges for replacements under this
warranty and labor costs not specifically covered by
this warranty, shall be the responsibility of the
purchaser. This warranty extends only to the original
purchaser of the U-Line product. The Product
Registration Card included with the product should be
promptly completed by you and mailed back to U-Line
or you can register on-line at www.u-lineservice.com.
3. The warranty listed above does not apply to floor
display models. The warranty for these models shall
be 30 days from the date of retail purchase and only if
U-Line’s Product Registration Card included with the
unit is completed and mailed back or electronically
submitted to U-Line. This 30 day warranty does not
apply to cosmetic damages. A proof of purchase may
be required.
4. The following conditions are excluded from this limited
warranty: use of cleaners other than the recommended
stainless steel cleaners and U-Line Clear Ice Maker
cleaner; installation charges; damages caused by
disasters or acts of God, such as fire, floods, wind and
lightning; damages incurred or resulting from shipping,
improper installation, unauthorized modification, or
misuse/abuse of the product; customer education
calls; food loss and spoilage; door and water level
adjustments (except during the first 30 days from the
date of installation); defrosting the product; adjusting
the controls; door reversal; and cleaning the
condenser.
5. U-Line product are designed to operate in ambient
temperatures between 50°F and 100°F unless
otherwise noted in the product manual. Exposure to
temperatures outside this range may cause
degradation of performance and issue such as lower ice
production or spoiled contents are not covered under
the terms of this warranty as a result of that exposure.
U-Line product may not be subjected to temperatures
below 40F without following the winterization and
vacation shutdown procedures in the user guide.
6. U-Line’s Outdoor Limited Warranty, set forth in this
Paragraph 6 shall apply to U-Line models deemed
suitable for outdoor use by Underwriters Laboratory
(“UL”) as noted in the U-Line Product Catalog, U-Line’s
website and/or on the serial tag located inside the
product.
A. Outdoor product may come into contact with rain by
virtue of outdoor use. Exposure to other sources of
water shall also cause this warranty to be void,
including flooding of the area in proximity of the unit
greater than 1/8" deep in water, hurricanes, splashing
of pool water, or directing a spray from a hose or
similar device into and around the unit.
Warranty 1
Page 34
USER GUIDE
u-line.com
SAFETY INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS MAINTENANCE SERVICE
7. If a product defect is discovered during the applicable
warranty period, you must promptly notify either
U-Line at 8900 N. 55th Street, Milwaukee, Wisconsin
53223 USA or at +1.800.779.2547 or the dealer from
whom you purchased the product. In no event shall
such notification be received later than 30 days after
the expiration of the applicable warranty period. U-Line
may require that defective parts be returned, at your
expense, to U-Line’s factory in Milwaukee, Wisconsin,
for inspection. Any action by you for breach of
warranty must be commenced within one year after
the applicable warranty period.
8. THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR IMPLIED WARRANTY OF
FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH
ARE DISCLAIMED. U-Line’s sole liability and your
exclusive remedy under this warranty is set forth in the
paragraphs above. U-Line shall have no liability
whatsoever for any incidental, consequential or special
damages arising from the sale, use or installation of
the product or from any other cause whatsoever,
whether based on warranty (express or implied) or
otherwise based on contract, tort or any other theory
of liability.
Some states do not allow limitations on how long an
implied warranty lasts or the exclusion or limitation of
incidental or consequential damages, so the above
limitations may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights
which vary from state to state.
Warranty 6/2014 Rev.G