UEi RACKtangle DNR-12-1G-02, HalfRACK DNR-6-1G, RACKtangle DNR-12-1G, RACKtangle DNR-12-1G-00, RACKtangle DNR-12-1G-01 User Manual

...
DNR-12-1G Series RACKtangle
and
DNR-6-1G Series HalfRACK
Data Acquisition Systems
User Manual
October 2018
PN Man-DNR-X-1G
© Copyright 1998-2018 United Electronic Industries, Inc. All rights reserved.
Information furnished in this manual is believed to be accurate and reliable. However , no responsibility is assumed for its use, or for any infringement of patents or other rights of third parties that may result from its use.
All product names listed are trademarks or trade names of their respective companies.
See the UEI website for complete terms and conditions of sale: http://www.ueidaq.com/cms/terms-and-conditions/
Contacting United Electronic Industries
Mailing Address:
27 Renmar Avenue Walpole, MA 02081 U.S.A.
For a list of our distributors and partners in the US and around the world, please contact a memb er of our support team:
Support:
Telephone: (508) 921-4600 Fax: (508) 668-2350
Also see the FAQs and online “Live Help” feature on our web site.
Internet Support:
Support: support@ueidaq.com Website: www.ueidaq.com FTP site: ftp://ftp.ueidaq.com
Product Disclaimer:
WARNING!
DO NOT USE PRODUCTS SOLD BY UNITED ELECTRONIC INDUSTRIES, INC. AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS.
Products sold by United Electronic Industries, Inc. are not authorized for use as critical components in life support devices or systems. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Any attempt to purchase any United Electronic Industries, Inc. product for that purpose is null and void and United Electronic Industries Inc. accepts no liability whatsoever in contract, tort, or otherwise whether or not resulting from our or our employees' negligence or failure to detect an improper purchase.
Specifications in this document are subject to change without notice. Check with UEI for current status.
DNR-X-1G Series RACKtangle and HalfRACK Systems i
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.

Table of Contents

Table of Contents
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Organization of This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Product Versions Described in This Manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 2 The DNR-12-1G Series RACKtangle System . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 PowerDNR DNR-12-1G System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 DNR-12-1G Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3 DNR-12-1G Key Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.4 DNR-12-1G RACKtangle Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4.1 DNR-12-1G Enclosure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4.2 DNR-12-1G Enclosure Common Components . . . . . . . . . . . . . . . . . . . . . . . . 8
2.4.3 DNR-12-1G Cooling Air Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.5 DNR-12 Power, NIC/CPU, and I/O Boards LEDs & Controls . . . . . . . . . . . . . . . . . . 14
2.6 DNR-POWER-DC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
2.7 DNR-CPU/NIC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.7.1 Device Architecture of DNR Core Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.8 DNR-Buffer Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.9 DNR I/O Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.10 DNR-12-1G DC Power Thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Chapter 3 The DNR-6-1G Series HalfRACK System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.1 PowerDNR DNR-6-1G System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.2 DNR-6-1G Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.3 DNR-6-1G Key Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
3.4 DNR-6-1G HalfRACK Enclosure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.4.1 DNR-6-1G Enclosure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.4.2 DNR-6-1G Enclosure Common Components . . . . . . . . . . . . . . . . . . . . . . . . 30
3.4.3 DNR-6-1G Cooling Air Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.5 DNR-6 Power, NIC/CPU, and I/O Boards LEDs & Controls . . . . . . . . . . . . . . . . . . . 33
3.6 DNR-6-1G DNR-POWER-DC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.7 DNR-6-1G DNR-CPU/NIC Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.8 DNR-6-1G DNR-IO-Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
3.9 DNR-6-1G DC Power Thresholds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Chapter 4 Installation and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.1 Initial Installation Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4.1.1 Inspect Package . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.1.2 Install Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
4.2 Initial Boot-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
4.3 IP Address Overview & Update Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
DNR-X-1G Series RACKtangle and HalfRACK Systems ii
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Table of Contents
4.3.1 When Should You Change the IP Address? . . . . . . . . . . . . . . . . . . . . . . . . . 41
4.3.2 How to Change the Primary IP Address (NIC1). . . . . . . . . . . . . . . . . . . . . . . 42
4.3.3 How to Change the Secondary (Diagnostic) IP Address (NIC2). . . . . . . . . . 43
4.4 Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
4.4.1 Example of Configuring Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
4.5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
4.6 Updating Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
4.6.1 Determining Currently Installed Firmware Version . . . . . . . . . . . . . . . . . . . . 51
4.6.2 Updating Firmware via PowerDNA Explorer . . . . . . . . . . . . . . . . . . . . . . . . . 52
4.6.3 Updating Firmware via Serial Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
4.7 Mounting and Field Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
4.7.1 Physical Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
4.7.2 Pinout Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.7.3 Network Wiring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
4.8 Wiring I/O Boards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.9 Repairing (and Upgrading) a DNR System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.10 Configuring a NIC Port for Diagnostic Mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
4.11 Disabling Writes to Flash/EEPROM (NVRAM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.11.1 Disabling NVRAM Writes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
4.11.2 Re-enabling NVRAM Writes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Chapter 5 PowerDNA Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
5.1 Getting Started with PowerDNA Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
5.1.1 Connecting PowerDNA Explorer to Your System . . . . . . . . . . . . . . . . . . . . . 70
5.2 Overview of the Main Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
5.2.1 Menu Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
5.2.2 Toolbar. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
5.2.3 Device Tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
5.2.4 Settings Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
5.3 Exploring I/O Boards with PowerDNA Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.3.1 Digital Input/Output Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
5.3.2 Analog Output Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
5.3.3 Analog Input Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
5.3.4 Counter/Timer Board Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
Chapter 6 Programming CPU Board-specific Functions . . . . . . . . . . . . . . . . . . . . . . . . 91
6.1 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.2 Memory Map Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
6.3 Startup Sequence. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93
6.4 Setting and Reading CPU Core Parameters via Serial Port. . . . . . . . . . . . . . . . . . . 93
6.4.1 Help Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
6.4.2 Show System Parameters Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
6.4.3 Set and Store Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
6.4.4 Reset DNR-X-1G Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
6.4.5 Password Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
6.4.6 Display Table of Installed Boards & Logic Version Command. . . . . . . . . . . 100
6.4.7 Display Power Diagnostics Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
DNR-X-1G Series RACKtangle and HalfRACK Systems iii
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Table of Contents
6.4.8 Memory Test/Memory Clear Command. . . . . . . . . . . . . . . . . . . . . . . . . . . . 103
6.4.9 Monitor CPU and Pbuf Usage Command . . . . . . . . . . . . . . . . . . . . . . . . . . 103
6.4.10 Clock and Watchdog Access Command . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
Appendix A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Network Interface Card Configuration
Appendix B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109
Field Replacement of Fuses on DNA and DNR Boards
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
DNR-X-1G Series RACKtangle and HalfRACK Systems iv
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.

List of Figures

List of Figures
Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Chapter 2 The DNR-12-1G Series RACKtangle System . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2-1 Typical DNR-12-1G RACKtangle System......................................................................4
2-2 DNR-12-1G Technical Specifications....... .....................................................................6
2-3 DNR-12-1G PowerDNR Product Features....................................................................7
2-4 Typical PowerDNR DNR-12 Enclosure (Exploded View)..............................................8
2-5 Typical PowerDNR DNR-12 Board Placement..............................................................9
2-6 Optional DNR-IO-Filler Panel for Empty Slots.............................................................11
2-7 DNR-BRACKET Reversible Mounting Bracket............................................................11
2-8 DNR Board Ejection/Insertion Lever Operation...........................................................12
2-9 DNR-12 Air Flow..........................................................................................................13
2-10 DNR-12-1G System Front Panel Arrangement............ ... ... ... ... .... ... ... ... .... ... ... ............14
2-11 DC Power Module LEDs..............................................................................................15
2-12 DNR-CPU-1000/-XX Module LEDs.............................................................................15
2-13 Typical I/O Module LEDs.............................................................................................16
2-14 DNR-POWER-DC Module...........................................................................................18
2-15 Functional Block Diagram of DNR-POWER-DC Module.............................................19
2-16 Functional Block Diagram of DNR-12 Enclosure.........................................................20
2-17 DNR-X-1G Series Core Module (CPU/NIC) ................................................................21
2-18 FreeScale PowerPC CPU/NIC Controller Architecture................................................22
Chapter 3 The DNR-6-1G Series HalfRACK System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3-1 Typical DNR-6-1G HalfRACK System.........................................................................25
3-2 DNR-6-1G Technical Specifications............................................................................27
3-3 DNR-6-1G HalfRACK Product Features......................................................................28
3-4 Typical HalfRACK DNR-6 Enclosure (Exploded View)....... ... ... ...................................29
3-5 Typical PowerDNR DNR-6 Board Placement..............................................................30
3-6 DNR-6 Air Flow............................................................................................................32
3-7 DNR-6-1G System Front Panel Arrangement.............................................................33
Chapter 4 Installation and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4-1 Typical MTTTY Screen after DNR-X-1G Boot-up........................................................40
4-2 System Configuration Using show Command.............................................................41
4-3 Using PowerDNA Explorer to Change IP Address......................................................42
4-4 Single DNR-X-1G Direct-Connected to Host without LAN Switch...............................44
4-5 Single Network for Operation and Diagnostics Using DNR Racks and LAN Switch ...44
4-6 Separate Networks for Operation and Diagnostics: Two Racks & Two Switches.......45
4-7 Typical Configuration for a Single DNR-X-1G with a LAN Switch ... ... ... ......................48
4-8 Displaying the Version of Your Firmware....................................................................51
4-9 Update Firmware Menu Item.......................................................................................52
4-10 Password Dialog Box ..................................................................................................53
4-11 Firmware Update Progress Dialog Box.......................................................................53
4-12 Firmware Update via Serial Port..................................................................................55
4-13 Physical Dimensions of DNR-12 Enclosure.................................................................56
4-14 Physical Dimensions of DNR-6 Enclosure...................................................................57
4-15 DNR-X-1G Pinout Diagrams........................................................................................58
4-16 System Configuration with LAN Switch.......................................................................58
4-17 DNR-X-1G NIC/CPU Core Module and Carrier...........................................................66
4-18 NVRAM Protection Jumper .........................................................................................67
DNR-X-1G Series RACKtangle and HalfRACK Systems v
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
List of Figures
Chapter 5 PowerDNA Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
5-1 PowerDNA Explorer ....................................................................................................69
5-2 Address Ranges to be Scanned..................................................................................70
5-3 Typical Screen for Analog Input Board........................................................................71
5-4 PowerDNA Explorer Main Window..............................................................................72
5-5 PowerDNA Explorer Timeout Preferences..................................................................72
5-6 Address Ranges Dialog Box........................................................................................73
5-7 Edit Address Ranges Dialog Box ................................................................................73
5-8 After a Network >>Scan Network................................................................................74
5-9 Password Dialog Box for “Store Config” and “Store All Configs”.................................75
5-10 Password Dialog Box for “Update Firmware . . .”........................................................75
5-11 Example of a Hardware Report...................................................................................76
5-12 Example of a Wiring Diagram Display.........................................................................77
5-13 PowerDNA Explorer Toolbar Buttons (Config Level)...................................................78
5-14 PowerDNA Explorer Toolbar Buttons (Board Level)....................................................78
5-15 Example of the Device Tree........................................................................................79
5-16 Example of IOM Settings Panel for HalfRACK DNR-6-1G..........................................80
5-17 Example of I/O Device Settings ..................................................................................81
5-18 Screen from Network >> Start Reading Input Data.....................................................82
5-19 Example DIO-403 Inputs.............................................................................................83
5-20 Example DIO-403 Outputs ..........................................................................................84
5-21 Example of DIO-403 Configuration..............................................................................85
5-22 Example AO-308 Board...............................................................................................86
5-23 Example AI-207 Board ................................................................................................87
5-24 Example CT-601 Module.............................................................................................88
5-25 Example Quadrature Controls.....................................................................................88
5-26 Example Bin Counter Controls....................................................................................89
5-27 Example Pulse Width Modulation (PWM) Controls.....................................................89
5-28 Example Pulse Period Controls...................................................................................89
5-29 Example Frequency Controls......................................................................................89
5-30 Example of Started Counter........................................................................................90
Chapter 6 Programming CPU Board-specific Functions . . . . . . . . . . . . . . . . . . . . . . . . 91
6-1 TCP/IP Properties........................................................................................................98
B-1 Location of Fuse for Base Boards Equipped with a Fuse..........................................109
B-2 Location of Fuses for DNR-POWER-DC Board ................. ... ... .... ... ... ... .... ................110
B-3 Location of Fuses for DNR-POWER-1GB Board.......................................................110
DNR-X-1G Series RACKtangle and HalfRACK Systems vi
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
List of Figures

List of Tables

Chapter 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1-1 Summary of DNR-X-1G/DNR-X-1G-XX Product Versions...........................................3
Chapter 2 The DNR-12-1G Series RACKtangle System . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2-1 Components in PowerDNR DNR-12 Enclosure............................................................9
2-2 Components in PowerDNR Core Module (DNR-CPU-1000 Series)...........................22
Chapter 3 The DNR-6-1G Series HalfRACK System . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3-1 Components in PowerDNR DNR-6 Enclosure............................................................30
Chapter 4 Installation and Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
4-1 Port States..................................................................................................................60
4-2 List of Functions and Associated Boards ...................................................................64
Chapter 5 PowerDNA Explorer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
5-1 Fields and Descriptions for IOM Settings Panel................................... .... ... ...............80
5-2 Fields and Descriptions for I/O Device Settings Panel................................ ... ... ... .... ..81
Chapter 6 Programming CPU Board-specific Functions . . . . . . . . . . . . . . . . . . . . . . . . 91
6-1 Memory Map for DNR-X-1G CPU (DNR-CPU-1000) .................................................91
6-2 Memory Map for DNR-X-1G-02 CPU (DNR-CPU-1000-02).......................................92
6-3 Memory Map for DNR-X-1G-03 CPU (DNR-CPU-1000-03).......................................92
6-4 Set Parameters...........................................................................................................97
B-1 DNA/DNR Replacement Fuses .. ... .... ... ... ... .... ... ... ... .... ... ... ... ... .... ... ... ... ....................109
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.

Chapter 1 Introduction

This document describes the features, performance specifications, and operating functions of the DNR-12-1G Series RACKtangle Series HalfRACK
RACKtangle and HalfRACK versions are identical except for the size of the enclosure and the number of IO boards that can be installed. Both are designed for use with a Gigabit Ethernet 1000 Base-T communication network.
This chapter provides the following information about the DNR-X-1G systems:
Organization of This Manual (Section 1.1)
Product Versions Described in This Manual (Section 1.2)
data acquisition systems.
DNR-X-1G Series RACKtangle and HalfRACK Systems
Chapter 1 1
Introduction
and the DNR-6-1 G

1.1 Organization of This Manual

This DNR-X-1G User Manual is organized as follows:
Chapter 1 – Introduction
This chapter describes the organi zation of the document and the conventions used throughout the manual.
Chapter 2 – DNR-12-1G Series RACKtangle
This chapter provides an overview of a DNR-12-1G system, features, accessories, and a list of all items you need for initial operation.
Chapter 3 – DNR-6-1G Series HalfRACK
This chapter provides an overview of a DNR-6-1G system, features, and accessories. It is essentially the same as the DNR-12-1G system except for enclosure size and number and arrangement of I/O boards.
Chapter 4 – Installation and Configuration
This chapter summarizes the recommended procedures for installing, configuring, starting up, and troubleshooting a DNR-X-1G system.
Chapter 5 – PowerDNA Explorer
This chapter provides a general description of the menus and screens of UEI’s GUI-based communication application, PowerDNA Explorer, when used with a DNR-X-1G system.
Chapter 6 – Programming CPU Board-specific Functions
This chapter describes tools and facilities used for programming board­specific functions.
System
System
Appendix A – Configuring Additional Ethernet Cards
This appendix describes procedures for installing and configuring Ethernet cards for use with Windows operating systems.
Appendix B – Field Replacement of Fuses
This appendix describes procedures for replacing fuses in the field.
Index
This is an alphabetical listing of topics covered in the manual, identified by page number.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Chapter 1 2
Introduction
Manual Conventions
To help you get the most out of this manual and our products, please note that we use the following conventions:
Tips are designed to highlight quick ways to get the job done, or reveal good ideas you might not discover on your own.
NOTE: Notes alert you to important information.
CAUTION! advises you of precautions to take to avoid injury, data loss, and damage to your boards or a system crash.
T ext formatted in bold typeface g enerally represents text that shou ld be entered verbatim. For instance, it can represent a filenames, as in the following example: “You can instruct users how to run setup using setup.exe executable.”
Bold typeface will also represent button names, as in “Click Scan Network.” Text formatted in fixed typeface generally represents commands,
source code, or other text that should be entered verbatim into the source code, initialization, or other file or at a command prompt.
Before you begin:
Before plugging any I/O connector into the chassis or board(s), be sure to remove power from all field wiring. Failure to do so may cause severe damage to the equipment.
No HOT SWAP
Always turn POWER OFF before performing maintenance on a UEI system. Failure to observe this warning may result in damage to the equipment and possible injury to personnel.
Usage of Terms
Throughout this manual, the term “Cube” refers to either a PowerDNA Cube product or to a PowerDNA RACKtangle applicable.
Additionally throughout this manual, the following conventions apply:
“DNR-X-1G” refers to both DNR-12-1G and DNR-6-1G types of systems. The DNR-12-1G can accept up to 12 I/O boards and the DNR-6-1G can accept up to 6 I/O boards. The two models are identical in all other respects.
rack mounted system, whichever is
Unless otherwise noted, “DNR-X-1G” applies to all versions of the RACKtangle and HalfRACK systems: DNR-X-1G (-00/-01), DNR-X-1G-02, and DNR-X-1G-03. Differences between product versions are noted on the following page.
Note that the -02 product version is a fully compatible upgrade of the
-00/-01 version.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Chapter 1 3
Introduction

1.2 Product Versions Described in This Manual

This user manual provides documentation for the DNR-X-1G series data acquisition systems: DNR-X-1G, DNR-X-1G-02, and DNR-X-1G-03 product versions.
Each product version is available in a DNR-12-1G RACKtangle chassis or a DNR-6-1G HalfRACK chassis.
T able 1-1 below provides a summary of features for each prod uct version. Refer to the following chapters in this manual for detailed descriptions.
NOTE: Unless otherwise noted, DNR-X-1G refers collectively to the
DNR-X-1G(-00/-01), DNR-X-1G-02, and DNR-X-1G-03 series of products.
Table 1-1 Summary of DNR-X-1G/DNR-X -1G-XX Product Versions
Item Summary of Features
DNR-X-1G (DNR-X-1G-00 / DNR-X-1G-01)
10/100/1000Base-T Ethernet interface
Freescale MPC8347 CPU
1PPS synchronization support
128 MB RAM
32 MB flash memory
2
2
1
DNR-X-1G-02 10/100/1000Base-T Ethernet interface
Freescale MPC8347 CPU
1PPS/IEEE-1588 synchronization support
Optional solid-state hard drives
3
1
256 MB RAM2
32 MB flash memory
2
DNR-X-1G-03 10/100/1000Base-T Ethernet interface
Freescale MPC8347E CPU, (encryption-ready / IPSec support pending)
1PPS/IEEE-1588 synchronization support
Optional solid-state hard drives
256 MB RAM
128 MB flash memory
2
2
3
1
1.1PPS and IEEE-1588 synchronization support is described in the PowerDNx 1PPS Sync Interface Manual.
2.RAM and flash memory are not user-accessible for PowerDNA applications (hosted deployment). Portions of RAM and flash are available for UEIPAC-based systems (stand-alone deployment). See UEIPAC docu­mentation for more information.
3.On UEIPAC-based systems (stand-alone deployment), solid state d rives are used for data and/or root file system storage.See UEIPAC documentation for more information.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
The DNR-12-1G Series RACKtangle System
Chapter 2 4

Chapter 2 The DNR-12-1G Series RACKtangle System

This chapter provides the following information about the DNR-12-1G Series RACKtangle
PowerDNR DNR-12-1G System Overview (Section 2.1)
DNR-12-1G Specifications (Section 2.2)
DNR-12-1G Key Features (Section 2.3)
DNR-12-1G RACKtangle Enclosure (Section 2.4)
DNR-12 Power, NIC/CPU, and I/O Boards LEDs & Controls
DNR-POWER-DC Module (Section 2.6)
DNR-CPU/NIC Module (Section 2.7)
DNR-Buffer Module (Section 2.8)
DNR I/O Boards (Section 2.9)
DNR-12-1G DC Power Thresholds (Section 2.10)
NOTE: For a list of product versions available for the DNR-12-1G Series
system:
(Section 2.5)
RACKtangle systems, refer to Section 1.2 on page 3.

2.1 PowerDNR DNR-12-1G System Overview

UEI PowerDNR DNR-12-1G RACKtangle systems are rack-mounted versions of the PowerDNA Cube Ethernet-based data acquisition systems.
The DNR-12-1G houses a PowerDNA data acquisition system in a rack enclosure with cabling, installation hardware, LEDs, and a power switc h accessible from the front of the rack chassis. Multiple DNR-12-1G systems may be mounted in a single rack. All standard DNA- Cube I/O boards are also available in DNR- RACK versions for use in DNR-12-1G systems.
Figure 2-1. Typical DNR-12-1G RACKtangle System
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Chapter 2 5
The DNR-12-1G Series RACKtangle System
A standard DNR-12-1G rack system consists of the following:
One or more DNR-12 rack mounted enclosure(s)
DNR-POWER-DC Power Module (one for each enclosure)
DNR-CPU-1000 or DNR-CPU-1000-XX Module
(Freescale MPC8347 or MPC8347E CPU and 1-GB Ethernet 1000 Base-T Network Interface Module — one for each enclosure)
DNR-BUFFER Board Module (one for each enclosure)
Optional DNR-IO-FILLER panels (one for each unused I/O slot) Note: These slot covers are optional and not included in the price of the
rack
DNA-PSU-180 180-Watt, 120/230 VAC to +24 VDC External Power Supply (one for each enclosure) with cable and Molex connector for plug-in to the DNR-POWER-DC Module front panel
T o configure a complete data acquisition system, insert up to 12 DNR I/O boards into each PowerDNR rack enclosure. I/O boards may be specified in any combination of UEI’s I/O boards.
All standard PowerDNA accessories are also available for use in a PowerDNR rack-mount system.
NOTE: For detailed descriptions of all I/O boards and accessories available for
DNR-X-1G systems, refer to www.ueidaq.com.
UEI stand-alone systems (UEIPAC, UEISIM, UEIModbus, and UEIOPCUA deployments) are also available for use with DNR-12-1G RACK systems:
UEIPAC 1200R - Programmable Automation Controller
UEISIM 1200R - Simulink / Simulink Coder Target
UEIModbus 1200R - Modbus TCP-based Controller
UEIOPCUA 1200R - OPC-UA Server, accessed by any OPC-UA client
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Standard Interfaces
To Host Computer Two independent 1000Base-T Gigabit Ethernet
ports (100/10Base-T compatible)
Distance from host 100 meters, max
Other Interfaces One USB 2.0 controller port, One USB 2.0 slave
port.
Cong/General RS-232, 9-pin “D”
Sync Custom cable to sync multiple racks
I/O Slots Available
DNR-12-1G 12 slots
Data transfer and communications rates
Ethernet data transfer rate
20 megabytes per second
Analog data transfer rate
up to 6 megasample per sec (16-bit samples)
DMAP I/O mode update 1000 I/O channels
(analog and/or digital)
in less than 1 millisecond, guaranteed
Processor
CPU Freescale 8347, 400 MHz, 32-bit
Memory 128 MB (not including on-board Flash)
Status LEDs Power supplies within spec, One second system
heart-beat, Attention, Read/Write, Power, Com­munications Active
Environmental
Temp (operating) Tested to -40 °C to 70 °C
Temp (storage) -40 °C to 85 °C
Humidity 0 to 95%, non-condensing
Vibration
(IEC 60068-2-64) 10–500 Hz, 3 g (rms), Broad-band random
(IEC 60068-2-6) 10–500 Hz, 3 g, Sinusoidal
Shock
(IEC 60068-2-27)
50 g, 3 ms half sine, 18 shocks at 6 orientations; 50 g, 11 ms half sine, 18 shocks at 6 orientations
MTBF 130,000 hours
Physical Dimensions
DNR-12 series 5.25” x 6.2” x 17.5” (3U in a 19” rack)
Power Requirements
Voltage 9 - 36 VDC (AC adaptor included)
Fuse Internal 10 A
Power Dissipation 13 W at 24 VDC (not including I/O boards)
Power Monitoring
I/O board power All internal power supplies monitored to ±1% ac-
curacy. All PS voltages may be read by host. LED annunciators indicate out of range
Input current Monitored by host, LED indicates overcurrent
Chapter 2 6
The DNR-12-1G Series RACKtangle System
2.2 DNR-12-1G Specifi-
Figure 2-2 lists the technical specifications of the DNR-12-1G PowerDNR
system.
cations
Figure 2-2. DNR-12-1G Technical Specifications
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Easy to Configure and Deploy
Over 30 different I/O boards available
Over 5 quadrillion possible configurations
Gigabit Ethernet based (100/10Base-T compatible)
Bracket kit for mounting to wall or in 19” racks
Industrial quality rubber feet for solid table-top mounting
Passive backplane ensures extremely low MTTR
Standard “Off-the-shelf” products and delivery
True Real-time Performance
1 msec updates guaranteed with 1000 I/O
Up to 6 million samples per second
Use QNX, RTX, 7Y8PSLT
Flexible Connectivity
1000Base-T with Cat-5 cable
Supports WIFI / GSM / Cell networks
Built-in USB 2.0 slave and controller ports
Compact Size:
5.25” x 6.2” x 17.5”
300 analog inputs per rack
384 analog outputs per rack
576 digital I/O bits per rack
96 counter/quadrature channels per rack
144 ARINC-429 channels per rack
48 RS-232/422/485 ports per rack
Low Power:
Less than 13 watts per typical rack (not including I/O)
AC, 9-36 VDC or battery powered
Standalone Modes
Upgradeable to UEI1"$ 1200R
Upgradeable to UEI4*. 1200R
Upgradeable to UEIModbus 1200R
Rugged and Industrial:
Solid Aluminum construction
130,000 hour MTBF
Operation tested from -40°C to +70°C
Vibration tested to 3 g, (operating)
Shock tested to 50 g (operating)
All I/O isolated from rack and host PC
Outstanding Software Support
Windows, Linux, RT Linux, Windows RT, RTX VXworks and
QNX operating systems
VB, VB .NET, C, C#, C++
MATLAB, LabVIEW, OPC, ActiveX support
Chapter 2 7
The DNR-12-1G Series RACKtangle System
2.3 DNR-12-1G
The following table is a list of key features of a DNR-12-1G PowerDNR system.
Key Features
Figure 2-3. DNR-12-1G PowerDNR Product Features
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Backplane
Mounting Brackets (2) (Reversible for rack or surface mounting)
Grounding Fingers
Add rubber feet (4) for tabletop mounting
Note: Top/Rear Cover Not Shown
The DNR-12-1G Series RACKtangle System
Chapter 2 8

2.4 DNR-12-1G RACKtangle Enclosure

2.4.1 DNR-12-1G
Enclosure
This section describes the DNR-12-1G chassis and provides an overview of common components included in every DNR-12-1G system.
The DNR-12 enclosure is a rigid mechanical structure with complete EMI shielding (see Figure 2-4 below). Unused slots can be filled with filler panels (filler panel diagram shown in Figure 2-6).
The DC/DC power module provides output voltages of 24, 3.3, 2.5, 1.5, and 1.2 VDC for the logic/CPU and 8 VDC to power the four cooling fans .
2.4.2 DNR-12-1G
Figure 2-4. Typical PowerDNR DNR-12 Enclosure (Exploded View)
NOTE: Note that the rightmost module (I/O board slot 12) is 2-slots wide (to
accommodate future designs and/or custom modules). Also note that the DNR-12 enclosure has reversible mounting flanges
designed for rack or surface mounting. Rubber feet are supplied for desktop or tabletop mounting. Refer to Section 4.7 on page 56 for more information about mounting options and field connections.
Each DNR-12-1G chassis contains a power board (DNR-POWER-DC) with
Enclosure Common Components
status indicators and an external ON/OFF switch. Each DNR-12-1G chassis also contains a CPU board with a dedicated GigE CPU and two Network Interface Control (NIC) ports, one for controlling up to 12 I/O boards mounted in the enclosure and another for diagnostics functions. Front-loading slots allow I/O boards to be quickly and easily installed and removed, as needed.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
DNR-POWER-DC DNR-CPU-1000/-XX DNR-BUFFER
up to 12 PowerDNR I/O Boards
Chapter 2 9
The DNR-12-1G Series RACKtangle System
Up to 12 DNR I/O boards can be installed in the chassis; DNR I/O boards are functionally identical to the corresponding DNA boards for the Power DNA Cube. The only differences between RACK and Cube I/O boards are the mounting hardware. The DNA version I/O boards are designed to stack in a Cube chassis. The DNR version I/O boards are designed to plug into the backplane of a RACK chassis.
Figure 2-5. Typical PowerDNR DNR-12 Board Placement
Table 2-1 Components in PowerDNR DNR-12 Enclosure
Item / Part No. Description
DNR-POWER-DC One isolated DC/DC Power Module/Power Monitor with status indicators, a local
on/off switch, and 4-pin Molex Power-In connector. (Refer to Section 2.6 for detailed information)
DNR-CPU-1000, DNR-CPU-1000-02, DNR-CPU-1000-03
DNR-BUFFER One for buf fering address/con trol/clock lines (not currently addr essable). (Refer to
PowerDNR I/O Boards
DNR-BP-12 One backplane with two temperature sensors (see Figure 2-4 for diagram) DNR-IO-FILLER Blank filler panels for all unused slots (see Figure 2-6. Note that this item is
One dual-slot CPU/NIC module with status indicators, two Ethernet connectors (Main and Diagnostic Ports), sync connector , reset pushbutton, SD card slot, USB controller/slave ports (reserved), and a DB-9 connector for a serial port. (Refer to Section 2.7 for detailed information)
Section 2.8 for detailed information) Up to 12 front pull-out I/O boards (DNR boards are functionally identical to
PowerDNA Cube I/O boards but designed for installation in a DNR rack enclosure). (Refer to Section 2.9 for detailed information)
optional / not included in price of rack)
Fans Four 8-volt cooling fans mounted on the rear of the enclosure (see Figure 2-9 for
air flow diagram)
All UEI modules are available in both PowerDNA and Power DNR package designs.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Chapter 2 10
The DNR-12-1G Series RACKtangle System
2.4.2.1 Physical
Addressing of DNR-12-1G Components
A feature of th e DNR-X-1G design is that the address of a module is determined by the position of the module within the enclosure, numbered from left to right. A typical module address is:
0xA00nxxxx
where A00 is the BASE address n is the module position number starting from 0 at the left xxxx is the address of the module With this addressing method, the address of a given I/O board (module) automatically changes if you move it from one position to another within the enclosure.
The slots or module positions are numbered as follows (left to right):
Physical Position Position Number Module Description
10xC POWER-DC 2 0x0 I/O Board 1 3 0x1 I/O Board 2 4 0x2 I/O Board 3 5 0x3 I/O Board 4 6 0x4 I/O Board 5 7 0x5 I/O Board 6 80xD
0xE
POWER-1GB
CPU/NIC 9 N/A BUFFER 10 0x6 I/O Board 7 11 0x7 I/O Board 8 12 0x8 I/O Board 9 13 0x9 I/O Board 10 14 0xA I/O Board 11 15 0xB I/O Board 12
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Grounding Fingers
Turn bracket upside down to use as surface or flange mounted device
Chapter 2 11
The DNR-12-1G Series RACKtangle System
2.4.2.2 DNR-IO­FILLER, DNR­BRACKET, & DNR- I/O Board Drawings
The following section provides drawings for the DNR-IO-FILLER, DNR-BRACKET, and DNR- I/O board extraction lever as found in DNR-X-1G systems.
Figure 2-6. Optional DNR-IO-Filler Panel for Empty Slots
Figure 2-7. DNR-BRACKET Reversible Mounting Bracket
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Lift Lever to eject board from backplane connector
Press lever down to insert board into backplane connector
DNR Backplane Connector
Chapter 2 12
The DNR-12-1G Series RACKtangle System
Figure 2-8. DNR Board Ejection/Insertion Lever Operation
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Chapter 2 13
The DNR-12-1G Series RACKtangle System
2.4.3 DNR-12-1G
Cooling Air Flow
As shown below in Figure 2-9, cooling air is drawn into the rear of the enclosur e via four fans, routed forward over the electronic circuit boards, up to the top of the enclosure, and then out the top rear of the enclosure. The system is designed to maintain positive pressure cooling within the enclosure at all times.
Figure 2-9. DNR-12 Air Flow
Two sensors mounted on the backplane over the Power Module and over the CPU board continuously monitor internal temperatures, turning fans on if the internal temperature exceeds 45°C, off if it falls below 45°C, and shutting down power if a high limit is exceeded.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
SD Card
USB B
USB A
NIC 1
NIC 2
Sync/Reset
RS-232
3.3
24
COM
USRR/W
PG
POWER
Module 1
Module 2
Module 3
Module 4
Module 5
Module 6
CPU/NIC
Buffer
Module 7
Module 8
Module 9
Module 10
Module 11
Module 12
Module
(dual width)
DNR-POWER-DC
Typical
I/O Board
Serial Port Connector
Status LEDs
NIC1 Port
NIC2 Port
Temp1 Sensor (on backplane)Temp0 Sensor (on backplane)
Status LEDs
DB Connector
V
in
1.5V User
Overtemp
24V
3.3V
I
in
I/O Attention 24V
3.3V
(7-12)
(1-6)
Power Conn.
PowerDNR
PowerDNR
Fan
Switch
0n/off
Power
DB-9
ATT Indicates error when red R/W Flashes when bus is active COM Flashes when SD Card is read/written PG Indicates presence of valid power input
LEDs
DC/DC Module
(Single Slot Model)
USB 2.0 USB 2.0
Controller
DNR-CPU-1000/-XX
CPU/NIC Module
PowerDNR
Slave Port
Port
Sync Conn/ RESET
SD Card Slot
Chapter 2 14
The DNR-12-1G Series RACKtangle System
2.5 DNR-12
Power, NIC/ CPU, and I/O Boards LEDs & Controls
DNR-12-1G LED indicators are illustrated in Figure 2-10. The power , CPU, and I/O board LEDs are individu ally described in Figure 2-11,
Figure 2-12, and Figure 2-13 respectively.
Figure 2-10. DNR-12-1G System Front Panel Arrangement
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Input Voltage OK/Error
1.5VDC OK/Error
User Controlled/Off (default)
LED ON/Off means:
Input Current OK/High Fans On/Off
I/O Circuit OK (flashes 1/sec))
LED ON/OFF means:
24VDC OK/Error -- Modules 7-12
3.3VDC OK/Error -- Modules 7-12
24VDC OK/Error -- Modules 1-6
3.3VDC OK/Error -- Modules 1-6
When flashing, module needs
Temp High/OK
Module Groups
attention
SD Card
USB B
USB A
NIC 1
NIC 2
Sync/Reset
RS-232
3.3
24
COM
USRR/W
PG
When Flashing,
Read/Write Activity
Serial Comm. Activity
Power Good
Module Needs Attention
Note: On a UEIPAC CPU/NIC module, the LEDs are user-programmable.
Temp High/OK
USB 2.0 Controller Port Type A Connector
USB 2.0 Slave Port Type B Connector (reserved for future use)
(reserved for future use)
Ethernet Ports NIC1 (Main),
Serial Port
User Controlled/Off
3.3VDC OK/Error 24VDC OK/Error
NIC2 (Secondary)
The DNR-12-1G Series RACKtangle System
Figure 2-11. DC Power Module LEDs
Chapter 2 15
Figure 2-12. DNR-CPU-1000/-XX Module LEDs
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Ready (Power ON)
Status
The DNR-12-1G Series RACKtangle System
Figure 2-13. Typical I/O Module LEDs
Chapter 2 16
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Chapter 2 17
The DNR-12-1G Series RACKtangle System
2.6 DNR-POWER-
DC Module
The DNR-POWER-DC Module is a dedicated DC/DC source and control module available only for use with a PowerDNR rack enclosure. It is always mounted in the leftmost slot of the DNR chassis and is recognized on the PowerDNR bus with an ID of 0x020 at address 0xA00C0000.
The non-isolated side (NIS) logic complies with full common logic interface (CLI) implementation. The key features of the DNR-POWER Module are:
Input power — 9-36 VDC 80W maximum, protected by resettable fuses and EMI chokes
Power supply on/off switch (with guard)
Output power sources (all with greater than 90% efficiency)
24V, 1A (24W)
3.3V, 5A (16.5W, including the 2.5V derived voltage)
2.5V, 3A (derived from 3.3V source)
1.5V, 5A, (7.5W, including the 1.2V derived voltage) 8V, 0.5A (4W for fans)
DC/DC for 24V , 3.3V , and 1.5V are synchron ized from the single spread­spectrum clock source in the CPU/NIC Module for lower EMI noise level
Fan control (Forced ON) and status ON/OFF
Monitoring and LED indicators (1% accuracy, 0.25Hz update rate)
for: – All output voltages
– Input current for the 9-36VDC for the DNR Enclosure – All voltages from the NIC Module (24V, 3.3V, 2.5V) – Temperature of the DNR backplane (2 sensors)
Onboard FPGA logic chip is CYCLONE EP1C3/C6T144
TI MSP4300 microcontroller used for logic reprogramming
Input-Output connector is a 128-pin component that provides 9-36VDC
for all modules from an external power source
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Ejection Lever
On/Off Switch
Power Connector
Indicating LEDs
Grounding
Fingers
(hidden)
Chapter 2 18
The DNR-12-1G Series RACKtangle System
Figure 2-14. DNR-POWER-DC Module
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
3.3V DC/DC
3.3V DC/DC
3.3V DC/DC
2.5V LDO
1.5V DC/DC
1.2V LDO
24V DC/DC
FAN3-4 CONTROL
8V FAN DC/DC
24-bit ADC (LTC2498) 13 sources: +2.5V, +2.5VNIC, 3.3V, +3.3VNIC, +24Vm +24VNIC, +VIN, +1.5V, +1.2V, +8V FAN, I
in
, TEMP1 (TCPOS), TEMP2 (TCNEG). Voltage sources use 1:23.1 dividers on the front end, except for the Vin, which uses a 1:45.3 divider.
Standard NIC-logic plus:
Access to ADC data readings Fan 1-2 and 3-4 ON/OFF control
 
Fan ON/OFF status
12 LEDs ON/OFF control
LED block – 12 status LEDs
Input Current
Monitor
+2.5V NIC
DNR Bus Connector
+3.3V NIC +24V NIC
TEMP1 TEMP2
FAN1-2 CONTROL
Input Voltage Source 9-36 VDC @ 80 W max.
1.2V
1.5V
24V
3.3V
2.5V
24V
8V
Vin
Chapter 2 19
The DNR-12-1G Series RACKtangle System
A functional block diagram of the DNR-POWER-DC Module is shown in Figure 2-15 below.
Figure 2-15. Functional Block Diagram of DNR-POWER-DC Module
As shown in Figure 2-15, the DNR-POWER-DC Module operates as follows: A 9-36 VDC voltage input (Vin) from an external source is connected to the
board through a replaceable slow-blow fuse. The board monitors the input current and passes Vin to the DNR bus as Vout.
Vout also is connected to DC/DC converters that produce 24 VDC, 3.3 VDC and
1.5 VDC output voltages, which are also placed on the DNR bus. Both 3.3 and
1.5 VDC voltages are connected to low dropout regulator s that, in turn, generate the 2.5 VDC and 1.2 VDC output voltages on the bus. The 24 VDC source is fed to a low dropout regulator that produces 8 VDC to drive the cooling fans (through fan controller chips).
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
CPU/NIC
PULLUPS
SLOTS
6...B
SLOTS
0..5, C
PWR
ADDR/CTRL
CLOCKS
TEMP1
TEMP0
2.5V
3.3V, 24V
1.2V AND 1.5V
2.5V,3.3V
ADDR/CTRL
CLOCKS
6
6
DNR-BUFFER/
CLOCK DIST.
DATA BUS
DNR-POWER-DC
PULLUPS
I/O
I/O
Chapter 2 20
The DNR-12-1G Series RACKtangle System
The input current and all output voltages, including the +2.5, +3.3, and +24 VDC from the NIC module, plus signals from the two temperature sensors mounted within the enclosure, are input to a 24-bit delta-sigma A/D converter. Except for Vin, the voltage sources use 1:23.1 divide rs on the front end. Vin uses a 1:45.3 divider.
Figure 2-16 shows the interaction of modules within a DNR-12 enclosure when the DNR-BUFFER module is used.
Figure 2-16. Functional Block Diagram of DNR-12 Enclosure
As shown above, the I/O slots are divided into two groups: 0 to 5 and 6 to 0xB. 0xC for the DC Power Module is included with the 0 to 5 group. The DNR­BUFFER board is located at the center of the enclosure, which is also at the center point of the ADDR/CTRL bus. The DNR-CPU-1000 module is also located at the center of the enclosure and the center of the data b us to minimize bus delays. The CPU addresses I/O Boards and transmits clock ticks through the Buffer Board, which controls the Addr/Ctrl and clock lines to the modules.
Temperature sensors monitor temperatures within the enclosure above the DNR-POWER-DC module and the DNR-CPU module.
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
Front Panel Isometric of Carrier
(holds two circuit boards – CPU and NIC)
SD Card
USB B
USB A
NIC 1
NIC 2
Sync/Reset
RS-232
3.3
24
COM
USRR/W
PG
DB-9 Connector for serial port
Diagnostic Port - NIC2
Primary Ethernet Port - NIC1
USB A USB B
Chapter 2 21
The DNR-12-1G Series RACKtangle System

2.7 DNR-CPU/NIC Module

The DNR-CPU/NIC Core Module (DNR-CPU-1000, DNR-CPU-1000-02, or DNR-CPU-1000-03) occupies two slots of a DNR-X-1G RACKtangle
enclosure. The DNR-CPU/NIC Core module consists of a Freescale (formerly Motorola)
MPC8347 or MPC8347E 32-bit 400 MHz CPU and per ipheral devices (USB 2.0, RS-232, NIC, SD, etc) for use with a Gigabit Ethernet communication network and an internal 66 MHz 32-bit common logic interface bus. The NICs are cop per (1000BaseT) interfaces. The module has an RS-232 port used for co nfiguration and also two USB 2.0 ports (controller and slave) for general purpose use (not implemented yet). LEDs on the front panel of each module indicate the current operating status of the device.
Figure 2-17. DNR-X-1G Series Core Module (CPU/NIC)
DNR-X-1G Series RACKtangle and HalfRACK Systems
October 2018 www.ueidaq.com
508.921.4600
© Copyright 2018
United Electronic Industries, Inc.
MAC
MAC
PPC 8347
DC/DC
9-36V DC Input
Power Out
Power In
SD Card RS-232
32-bit 66-MHz bus
RJ-45
RJ-45
PHY
PHY
RTC
DDR2
FLASH
MII
1000-BASE-T
MII
FPGA
USB 2.0
USB 2.0
,(((QHWZRUNV\QFKURQL]DWLRQVXSSRUWRQDQG&38YHUVLRQV
Chapter 2 22
The DNR-12-1G Series RACKtangle System
2.7.1 Device
Architecture of DNR Core Module
Figure 2-17 shows the architecture of the DNR-CPU-1000 Series Core
Modules:
Figure 2-18. FreeScale PowerPC CPU/NIC Controller Architecture
The core of the system is a Freescale PowerPC MPC834 7 or MPC8347E 32-bit 400 MHz processor, which controls the following components:
Table 2-2 Components in PowerDNR Core Module (DNR-CPU-1000 Series)
Item Description
NIC1: Primary Network Interface MII Port
NIC2: Diagnostic Network Interface MII Port
RS-232 Port The RS-232 port provides a serial communication link between the DNR-X-1G
USB 2.0 Dual Port (Controller and Slave)
32 MB or 128 MB Flash Memory
1
The NIC1 port provides communication between the DNR system and the primary LAN network.
The NIC2 port provides access to the DNR system for monitoring system health during operation, using a separate diagnostic port. This port may also be assigned as the primary Ethernet port if NIC1 is not available for use.
system and a standard RS-232 terminal. The USB A and B ports are not supported on DNR-X-1G (hosted) systems
(only supported on UEIPAC, UEISIM, UEIModbus, and UEIOPC-UA deployments).
DNR-X-1G (-00/-01) systems provide 32 MB of flash memory (DNR-CPU-
1000). DNR-X-1G-02 systems provide 32 MB of flash memory (DNR-CPU-1000-02). DNR-X-1G-03 systems provide 128 MB of flash memory (DNR-CPU-1000-03).
Loading...
+ 90 hidden pages