UEi INF151 Instruction Manual

1-800-547-5740 • Fax: (503) 643-6322
www.ueiautomotive.com • email: info@ueitest.com
INF151
INSTRUCTION MANUAL
Introduction
Congratulations on your purchase of the INF151 infrared thermometer. Like all UEi products, we selected the features and functions of this instrument to ensure that you’re getting the highest value possible.
Use the INF151 to make temperature measurements the fast, safe and easy way. Its compact size lets you get into tight places while its convenient laser targeting and high distance-to-spot ratio gives you accurate readings on distant targets.
NOTE: The INF151 is not recommended for use on shiny surfaces such as chrome, mirrors or polished metals.
To avoid thermal shock do not store the meter below freezing
Features include
• Precise non-contact measurements
• Switchable ˚C/˚F temperature units
• Automatic Data Hold
• Laser target pointer
Safety Notes
Before using this infrared thermometer, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument.
Laser Sight
The INF151 is classified as a "Class II Laser Product" and is regulated by the FDA
WARNING!
Using controls, making adjustments, or performing procedures in any manner other than that specified herein may result in hazardous radiation exposure.
• Class II laser products can cause injury if the beam makes prolonged eye contact
• Do not point the laser toward the eyes or face of a person
or animal
• Laser's potential to cause damage is retained for hundreds
of feet
• Refer to the maintenance section of this manual in the event
of a laser failure
Safe Practices
This instrument is designed for professionals who know the hazards associated with their trade. While this instrument offers no foreseeable dangers beyond its laser sight, the equipment you are servicing, as well as the environment you're working in, can be hazardous. These are a few common safety practices for those working around temperature critical environments:
• Follow the manufacturer's maintenance procedures when servicing equipment
• Verify that an infrared thermometer is suitable for the type of material you are measuring
• Before using this instrument to determine if an area is safe to
touch or enter, verify your readings are reasonably accurate by comparison with known measurements
• Properly maintain your INF151 and calibrate it regularly
C o n t r ols and Indicators
Controls
1. Trigger: Initiates measurements.
2. Scale Button: Toggles between ˚F and ˚C.
3. Laser Button: Turns laser on or off.
4. Back Light Button: Turns LCD display back light on or off.
5. Emissivity: Select one of the three pre-set values.
6. IR Sensor:
7. Laser Pointer Beam:
8. LCD Display:
9. Battery Compartment:
Indicators
1. Polarity Indicator: Appears when measuring negative
temperature.
2. Numerical Display: Indicates measured temperature value.
3. Laser Splash: Appears when laser is active.
4. Scale Icons: Indicate that either the Fahrenheit (˚F) or
Celsius (˚C) scale is selected.
5. Selectable Emissivity: Use to choose 0.85, 0.90, or 0.95
1.
2.
3.
4.
8.
7.
6.
9.
5.
1.
2.
3.
4.
5.
INF151-MAN P. 1
Loading...
+ 3 hidden pages