UEi ECT690 Instruction Manual

1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • email: info@ueitest.com
ECT690
INSTRUCTION MANUAL
Introduction
Use the ECT690 to perform quick checks of AC Volts, DC Volts, and Continuity. LED’s indicate Voltage level and DC polarity, tone provides audible indication of Continuity.
Features include
• AC Volts 12 to 690
• DC Volts 6 to 220
• Continuity
• One year limited warranty
Safety Notes
• Never use the tester if it or its test leads appear damaged.
• Never apply more than 1000V DC or 1000V AC rms. between any terminal and earth ground.
• I n d i cates dangerous voltage present at the terminals if the LED turns on.
• When using the probes, do not touch the metal probe tips.
• Disconnect the live test lead before disconnecting the common test lead.
• Before each use, verify the tester’s operation by measuring a known voltage.
Operating Instructions
Automatic Operation
The tester automatically turns on when you place the probes across a complete circuit. The tester selects continuity or DC or AC voltage mode based on the resistance or voltage between the probes. The tester automatically turns off when you remove the probes from the complete circuit.
Measuring Voltage
Connect test leads across the source or load under measurement. The LEDs turn on at between 70% and 100% of their rated voltages.
DC Voltage AC Voltage 1000V DC maximum 1000V rms. maximum
45 Hz to 66 Hz
Testing for Continuity
Turn off circuit power before testing. Beeper indicates shorts lasting 1 ms or longer.
M a i n t e n a n c e
Battery Test and Replacement
Replace the batteries when touching the leads together no longer turns on the continuity LED. Reference to (Fig 1) to replace batteries.
NOTE: Disconnect probes from voltage.
NOTE: Do not over-tighten screws
Observe battery polarity.
S p e c i f i c a t i o n s
ECT690-MAN P. 1
Function Range Accuracy
AC Voltage (V) 12, 24, 48, 110, 230, 400, 690 -30% to 0% of reading DC Voltage (V) 6, 12, 24, 36, 48, 110, 220 -30% to 0% of reading Continuity Test Audible threshold 0 - 85Ω, Continuity beeper 2KHz Maximum Voltage Between any terminal and earth ground: 1000V DC,
1000V AC rms, overvoltage category III Input Impudence 1MΩ Relative Humidity 90% (0˚-30˚C), 75% (30˚-40˚C), 45% (40˚-50˚C) Battery Type and Life (2) “AA”, 350 hours with NEDA 15F r IEC R6 Safety Complies with EN61010-1:1993 for use in overvoltage
CAT III environments EMC Regulations EN50081-1, EN50082-1
(Fig 1)
Continuity
Beeping
Continuity
+VDC -VDC
VDC
+-
6
12
24
-+
+VDC -VDC
VDC
6
12
24
VAC
VAC
12
24
24
48
110
230
400
12V DC
12V DC
110V AC
Open
Short or 0 - 85KΩ