UEi DT10K Instruction Manual

1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • email: info@ueitest.com
DT10K
INSTRUCTION MANUAL
• Keep your fingers away from the test lead metal probe contacts and bus-bars when making measurements. Always grip the instrument and test-leads behind the hand guards (molded into the probes).
• In the event of electrical shock, ALWAYS bring the victim to
the emergency room for evaluation, regardless of the victim’s apparent recovery. Electrical shock can cause an unstable heart rhythm that may need medical attention.
International Symbols
Operating Instructions
NOTE: Make sure the DT10K turns completely off when changing meas­urement modes. Failing to do so may result in incorrect or erroneous readings.
Temperature Measurement
1. Set the selector switch on the DT 10K to the ˚C or ˚F position.
2. Place the tip of the temperature probe into the medium to
be measured.
3. A l l ow 3 0 seconds for reading to stabilize in liquides, 2 minutes to
stabilize in semisolids and circulating air.
Minimum/Maximum Temperature Measurement
NOTE: Follow reset procedures before the start of any measurement sequence where minimum and maximum temperatures are required. This includes when the measurement mode is changed from ˚F to ˚C or vise versa and the DT10K was already reset.
Setting up DT10K for MIN/MAX Temperature Readings
1. Set the selector switch to the ˚C or ˚F position.
2. Place the tip of the temperature probe into the medium to
be measured.
3. A l l ow 3 0 seconds for reading to stabilize in liquides, 2 minutes to
stabilize in semisolids and circulating air.
4. Fo l l ow minimum/maximum reset procedures.
Introduction
The DT 10K is a versatile handheld temperature tester in a convenient pocket ca s e .
Features include
• -40˚ to 300˚F (-40˚ to 150˚C)
• ˚F/˚C switchable
• Large LCD digital display
• MIN/MAX record
• Attached stem-type probe
Safety Notes
Before using this meter, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument.
WARNING!
Exceeding the specified limits of this meter is dangerous and can expose the user to serious or possibly fatal injury.
DO NOT attempt to measure any voltage that exceeds 600 volts with this meter - UEi offers numerous alternatives for measuring high voltage and current
• Voltages above 60 volts DC or 25 volts AC may constitute a serious shock hazard
DO NOT attempt to use this meter if either the meter or the test leads have been damaged. Send unit in for repair by a qualified repair facility
• Test leads must be fully inserted prior to taking measurements
• Always turn off power to a circuit (or assembly) under test before cutting, unsoldering or breaking the current path. Even small amounts of current can be dangerous
• Always disconnect the live test lead before disconnecting the common test lead from a circuit
• When measuring high voltage, disconnect the power source before making test lead connections. Connect the test leads to the meter first then to the circuit under test. Reapply power
• If any of the following indications occur during testing, turn
off the power source to the circuit under test:
• Arcing
• Flame
• Smoke
• Extreme Heat
• Smell of Burning Materials
• Discoloration or Melting of Components
• Read the safety precautions associated with the equipment being tested and seek assistance or advice when performing unfamiliar tasks.
DT10K-MAN P. 1