• Test Leads: Test leads w/alligator clips CATIV 600V/CATII 1000V
IP42, 6’ Drop Protetion, RoHS,
IMPORTANT SAFETY WARNINGS
WARNING
Read entire Safety Notes section regarding potential hazard and proper
instructions before using this meter. In this manual the word “WARNING” is
used to indicate conditions or actions that may pose physical hazards to the
user. The word “CAUTION” is used to indicate conditions or actions that may
damage this instrument.
WARNING
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
WARNING
• Before each use, verify meter operation by measuring a known voltage
or current.
• Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
• Do not use this meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear damaged.
• Ensure meter leads are fully seated and keep fingers away from the
metal probe contact when making measurements. Always grip the leads
behind the finger guards molded into the probe.
• Do not open the meter to replace batteries while the probes are
connected.
3
IMPORTANT SAFETY WARNINGS (CONT.)
• Use caution when working with voltages above 60V DC or 25V AC RMS.
Such voltages pose shock hazards.
• To avoid false readings that can lead to electrical shock, replace
batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lockout power before
measuring resistance or capacitance.
• Always adhere to national and local safety codes. Use proper personal
protective equipment (PPE) to prevent shock and arc blast injury where
hazardous live conductors are exposed.
• Always turn off power to a circuit or assembly under test before cutting,
unsoldering or breaking the current path. Even small amounts of current
can be dangerous.
• Always disconnect the live test lead before disconnecting the common
test lead from the circuit.
• In the event of electrical shock, ALWAYS bring the victim to the
emergency room for evaluation, regardless of victim’s apparent recovery.
Electrical shock can cause unstable heart rhythms that may need
medical attention.
• If any of the following occurs during testing, turn off the power source to
the circuit being tested: arcing, flame, smoke, extreme heat, smell of
burning materials or discoloration melting of components.
WARNING
Higher voltages and currents require greater awareness of physical safety
hazards. Before connecting the test leads, turn off power to the circuit under
test, set meter to the desired function and range, connect the test leads to
the meter first, then connect to the circuit under test. Reapply power. If an
erroneous reading is observed, disconnect power immediately and recheck all
settings and connections.
WARNING
This meter is designed for trade professionals who are familiar with the
hazards of their trade. Observe all recommended safety procedures that
include proper lock-out utilization and use of personal protective equipment
that includes safety glasses, gloves and flame resistant clothing.
CATEGORY DEFINITIONS
Measurement
Category
II< 10Circuits connected to mains socket
III< 50Mains distributions parts of the building
IV> 50Source of the mains installation in the
Short-Curcuit
(typical) kA
a
outlets and similar points in the MAINS
installation
building
Location in the
building installation
4
SYMBOLS
AC (Alternating current)DC (Direct current)
Negative DCAC/DC Voltage or Current
Auto-ranging
Auto power off ActiveNon-Contact Voltage
Low BatteryHold/Capture Value
Minimum measured value
displayed
Duty CycleHertz/Frequency
Voltage
Ohms/ResistanceDiode
Capacitance mode in
nanofarads or microfarads
Degrees FahrenheitDegrees Celsius
ContinuityMega (x106 or 1,000,000)
Milli (x10-3 or 0.001)Kilo (x103 or 1,000)
Nano (x10-9 or 0.000000001)
Microamps Warning or Caution
GroundDangerous Levels
Double Insulation
(Protection to Class II)
Overload: Range Exceeded
Maximum measured value
displayed
Amperage
Microfarad
µF
Micro (x10-6 or 0.000001)
Safe for disconnect from
live conductors
OVERVIEW
C
A
600V 600A
NCV
A
μ
V
MAX/
H
z
/
D
MIN
PEAK
DL489
CATII 1000V
B
CAT III
T
e
A
m
p
/
°
F
°
C
MFD
u
t
y
True RMS
T1
30V
T2
CATIII
600V
MAX
TEMP
INRUSH
D
G
J
RANGE
DC
Zero
M
N
O
R
X
Y
S
U
W
Z
S/N
V
5
E
F
H
I
K
L
P
Q
T
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.