DL479
Visit us at www.TestEquipmentDepot.com
AC 600A TRMS HVAC/R
Clamp Meter
INSTRUCTION MANUAL
ENGLISH
CAT Ill
1000V 600A
DL479
°C°F
NCV
µA
A
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
True RMS
600V
CAT IV
MAX/MIN
Hz / Duty
1000V
CAT III
CAT IV 600V
CAT III 1000V
MAX
CATEGORY DEFINITIONS
Measurement
Category
II < 10 Circuits connected to mains socket
III < 50 Mains distributions parts of the building
IV > 50 Source of the mains installation in the
Short-Circuit
(typical) kA
a
outlets and similar points in the MAINS
installation
building
Location in the
building installation
WARRANTY
The DL479 is warranted to be free from defects in materials and workmanship
for a period of two years from the date of purchase. If within the warranty
period your instrument should become inoperative from such defects, the unit
will be repaired or replaced at UEi’s option. This warranty covers normal use
and does not cover damage which occurs in shipment or failure which results
from alteration, tampering, accident, misuse, abuse, neglect or improper
maintenance. Batteries and consequential damage resulting from failed
batteries are not covered by warranty.
Any implied warranties, including but not limited to implied warranties of
merchantability and fitness for a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the instrument or other
incidental or consequential damages, expenses, or economic loss, or for any
claim or claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase date will be required
before warranty repairs will be rendered. Instruments out of warranty will be
repaired (when repairable) for a service charge.
This warranty gives you specific legal rights. You may also have other rights,
which vary from state to state.
DISPOSAL
CAUTION: This symbol indicates that equipment and its accessories
shall be subject to separate collection and correct disposal.
CLEANING
Periodically clean your meter’s case using a damp cloth. DO NOT use abrasive,
flammable liquids, cleaning solvents, or strong detergents as they may damage the
finish, impair safety, or affect the reliability of the structural components.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time.
Do not expose to high temperatures or humidity. After a period of storage in extreme
conditions exceeding the limits mentioned in the General Specifications section, allow
the instrument to return to normal operating conditions before using it.
Copyright © 2016 UEi. All Rights Reserved.

FEATURES
• True RMS
• 600A AC
• 750V AC/600V DC
• Resistance 60MΩ
• Capacitance 2000µF
• Temperature -31˚ to 752˚F (-35˚ to 400˚C)
• DC Microamps 2000µA
• Frequency/Duty Cycle
• Data hold
• Min/Max (25 ms fast capture)
• Manual ranging option
• Backlight
• Worklight
• Audible voltage indicator
• Low battery indicator
• Auto power off
• Test lead storage
• Overmolded grip
• Magnetic mount
• Battery compartment latches
GENERAL SPECIFICATIONS
• Operating Temperature: 32° to 104°F (0° to 40°C)
• Storage Temperature 14° to 122°F (-10° to 50°C)
• Operating Humidity: <75%
• Operating Altitude: 6,562 ft. (2000m)
• Pollution Degree: 2
• Display: 3 5/6" Digits 6,000 Count
• Backlight: Yes
• Refresh Rate: 3/sec
• Over-range: “OL” is displayed
• Dimensions: 8.75” X 3.5” X 1.75”
• Item Weight: 0.65 lb
• Calibration: Recommended Annually
• CAT Rating: CAT IV 600V / CAT III 1000V
• Certifications: cETLus 3rd Edition, CATIII 1000V, IEC 61010-1, 61010-2-032,
• Battery Type: (AAA) X 2
• Test Leads: Test lead w/Alligator Clips
• Accuracy: ± (% of reading + # of least significant digits)
61010-2-033, CSA C22.2, NO. 61010-1, 61010-2-032,
61010-2-033, 6’ Drop Protection, RoHS Compliant,
CE Conformity
IMPORTANT SAFETY WARNINGS
WARNING
Read entire Safety Notes section regarding potential hazards and proper
instructions before using this meter. In this manual the word “WARNING” is
used to indicate conditions or actions that may pose physical hazards to the
user. The word “CAUTION” is used to indicate conditions or actions that may
damage this instrument.
WARNING
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
WARNING
• Before each use, verify meter operation by measuring a known voltage
or current.
• Never use the meter on a circuit with voltages that exceed the category
based rating of this meter.
• Do not use this meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear damaged.
• Ensure meter leads are fully seated and keep fingers away from the
metal probe contact when making measurements. Always grip the leads
behind the finger guards molded into the probe.
• Do not open the meter to replace batteries while the probes are
connected.
• Use caution when working with voltages above 60V DC or 25V AC RMS.
Such voltages pose shock hazards.
• To avoid false readings that can lead to electrical shock, replace
batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lockout power before
measuring resistance or capacitance.
• Always adhere to national and local safety codes. Use proper personal
protective equipment (PPE) to prevent shock and arc blast injury where
hazardous live conductors are exposed.
• Always turn off power to a circuit or assembly under test before cutting,
unsoldering or breaking the current path. Even small amounts of current
can be dangerous.
• Always disconnect the live test lead before disconnecting the common
test lead from the circuit.
• In the event of electrical shock, ALWAYS bring the victim to the
emergency room for evaluation, regardless of victim’s apparent recovery.
Electrical shock can cause unstable heart rhythms that may need
medical attention.
• If any of the following occur during testing, turn off the power source to
the circuit being tested: arching, flame, smoke, extreme heat, smell of
burning materials or discoloration or melting of components.
WARNING
Higher voltages and currents require greater awareness of physical safety
hazards. Before connecting the test leads, turn off power to the circuit under
test, set meter to the desired function and range, connect the test leads to
the meter first, then connect to the circuit under test. Reapply power. If an
erroneous reading is observed, disconnect power immediately and recheck all
settings and connections.
WARNING
This meter is designed for trade professionals who are familiar with the
hazards of their trade. Observe all recommended safety procedures that
include proper lock-out utilization and use of personal protective equipment
that includes safety glasses, gloves and flame resistant clothing.
SYMBOLS
AC (Alternating current) DC (Direct current)
Negative DC AC/DC Voltage
Auto-ranging Overload: Range Exceeded
Auto power off Active Low Battery
Non-Contact Voltage
Hold/Capture Value Duty Cycle
Maximum measured value
displayed
Hertz/Frequency Ohms/Resistance
Amperage
Diode Degrees Celsius
Degrees Fahrenheit Continuity
High Voltage Indication Milli (x10-3 or 0.001)
Mega (x106 or 1,000,000) Nano (x10-9 or 0.000000001)
Kilo (x103 or 1,000) Warning or Caution
Micro (x10-6 or 0.000001) Dangerous Levels
Ground
Double Insulation (Protection
to Class II)
Minimum measured value
displayed
Voltage
Capacitance mode in
nanofarads or microfarads
Safe for disconnect from live
conductors