Ubiquiti M5 User Guide

M5
OEM Users Guide
DataRate Avg. TX Tolerance DataRate Sensitivity Tolerance 1-24Mbps 27 dBm +/-2dB 24Mbps -83 dBm +/-2dB 36Mbps 25 dBm +/-2dB 36Mbps -80 dBm +/-2dB 48Mbps 23 dBm +/-2dB 48Mbps -77 dBm +/-2dB 54Mbps 22 dBm +/-2dB 54Mbps -75 dBm +/-2dB
MCS0 27 dBm +/-2dB MCS0 -96 dBm +/-2dB MCS1 27 dBm +/-2dB MCS1 -95 dBm +/-2dB MCS2 27 dBm +/-2dB MCS2 -92 dBm +/-2dB MCS3 27 dBm +/-2dB MCS3 -90 dBm +/-2dB MCS4 26 dBm +/-2dB MCS4 -86 dBm +/-2dB MCS5 24 dBm +/-2dB MCS5 -83 dBm +/-2dB MCS6 22 dBm +/-2dB MCS6 -77 dBm +/-2dB MCS7 21 dBm +/-2dB MCS7 -74 dBm +/-2dB MCS8 27 dBm +/-2dB MCS8 -95 dBm +/-2dB MCS9 27 dBm +/-2dB MCS9 -93 dBm +/-2dB MCS10 27 dBm +/-2dB MCS10 -90 dBm +/-2dB MCS11 27 dBm +/-2dB MCS11 -87 dBm +/-2dB MCS12 26 dBm +/-2dB MCS12 -84 dBm +/-2dB MCS13 24 dBm +/-2dB MCS13 -79 dBm +/-2dB MCS14 22 dBm +/-2dB MCS14 -78 dBm +/-2dB MCS15 21 dBm +/-2dB MCS15 -75 dBm +/-2dB
Operating Temperature
Networking Interface
SYSTEM INFORMATION
Processor Specs
Memory Information
REGULATORY / COMPLIANCE INFORMATION
Wireless Approvals
RoHS Compliance
OPERATING FREQUENCY 5745MHz-5825MHz
5GHz TX POWER SPECIFICATIONS
5GHz RX SPECIFICATIONS
11a
11a
5GHz 11n
5GHz 11n
Enclosure Characteristics
Mounting Kit
PHYSICAL / ELECTRICAL / ENVIRONMENTAL
Enclosure Size
Weight
Operating Humidity
Shock and Vibration
Max Power Consumption
Power Supply
Power Method
TECH SPECS
COMPLIANCE INFORMATION
FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
!
The antennas used for this transmitter must be installed to provide a separation distance of at least 252cm from all persons and must not be located or operating in conjunction with any other antenna or transmitter.
!
INDUSTRY CANADA
This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à! la norme NMB-003 du Canada.
!
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
!!
To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.!
This equipment is required to be professionally installed
The device has been designed to operate with the antennas listed below and having a maximum gain of 30dBi. Antennas not included in this list or having a gain greater than 30dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms
2x2 Point-To-Point Use Ubiquiti RD-5G-30 Ubiquiti RP-5G-24 Ubiquiti AMS-5G-20
1x1 Point-To-Point Use Ubiquiti AG-5G-30
2x2 Point-To-MultiPoitn Use Ubiquiti O-5G-7
Operation is restricted to Point-To-Point use for antenass other than the Ubiquiti O-5G-7 listed above.