MV Series
UL Recognized
CSA Certified
VDE Approved
CORCOM Product Guide
Multi-purpose Medical Filter for Power Line Noise Protection
with Limited Leakage Current
3A, 6A, 10A
MV Series
The MV series answers the need for a medical filter to help
equipment comply with increasing noise sources in
medical applications while still meeting leakage current
requirements of UL2601.
Less strict than previous UL medical standards, UL2601
limits leakage current for patient care equipment. Due to
the increased need for higher performance filtering, UL has
allowed more leakage current than in previous standards.
The MV takes advantage of this to offer improved line-toground performance in a moderately priced filter. Higher
line-to-line performance is achieved through its additional
differential mode rod inductors. Overall, the filter provides
a good solution to emission and immunity problems, at a
moderate cost, in a reasonable package size.
Electrical Schematic
Resistor location for reference only.
Specifications
Maximum leakage current,each line-to-ground
@ 120 VAC 60 Hz: .07 mA
@ 250 VAC 50 Hz: .13 mA
Hipot rating (one minute):
line-to-ground 2250 VDC
line-to-line 1450 VDC
Operating frequency: 50/60 Hz
Rated voltage (max.): 250 VAC
Rated current:
3MV 3A
6MV 6A
10MV 10A
20MV 20A
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current Frequency-MHz
Rating .15 .5 1 2 5 10 20 30
3A 14 19 20 30 46 40 34 31
27 30 38 50 40 35 35
6A
10A 15 25 26 34 46 50 44 42
20A 18 30 34 34 46 40 36 20
Line-to-line in 50 ohm circuit
Current Frequency-MHz
Rating .15 .5 1 2 5 10 20 30
3A 33 65 65 65 65 60 53 50
6A 40 65 65 65 65 60 57 55
10A
20A 25 65 65 65 65 60 57 45
19
33 65 65 65 65 65 55 55
78
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics
are metric equivalents. to change.
Specifications subject
Germany: 49-89-6089-0
CORCOM Product Guide
D
E
A
C
B
Slots:
.250 x .156
6
.35 x 3.96
(4)
2.00
50.8
Multi-purpose Medical Filter for Power Line Noise Protection
ith Limited Leakage Current
w
(Continued)
MV Series
Case Styles
3/6/10 MV1
ypical dimensions:
T
erminals: .250 [
T
Slot: .07 x .16 [
20A
.35](5) Holes: .07 [1.8]Dia.(4)
6
1.8 x 4.1] Mounting holes: .188 [4.78] Dia. (2)
Case Dimensions
ABC DE
Part No. (max) (max) (max) (max)
3MV1
6MV1
10MV1
20MV1
3.36 1.82 1.28 2.375 2.78
85.3 46.2 32.5 60.33 70.6
3.86 2.08 1.53 2.938 3.34
98.0 52.8 38.9 74.63 84.8
3.86 2.08 1.53 2.938 3.34
98.0 52.8 38.9 74.63 84.8
5.23 3.38 1.53 3.75 4.20
132.8 85.9 38.9 95.25 106.7
± .015
± .38
Part Numbers
03MV1
06MV1
10MV1
20MV1
RFI Power Line Filters
Typical dimensions:
Terminals: .250 [
Slot: .07 x .16 [
6.35] (5) Holes: .07 [1.8] Dia.(4)
1.8 x 4.1]
79
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics
are metric equivalents. to change.
Specifications subject
Germany: 49-89-6089-0