Tweco QRM-100 User Manual

Page 1
50 60
Hz
1
PHASE
GTAW
SMAW
INVERTER
115V230
V
QRM-100
English
Français
ANTI-SPATTER
MIST APPLICATOR
Español
Installation and Operation
Guide
Version No: AA.01 Issue Date: July 1, 2006 Manual No: SM-QRM-100
Page 2
WE APPRECIATE YOUR BUSINESS!
Congratulations on your new Tweco® Robotics product. We are proud to have you as our customer and will strive to provide you with the best service and reliability in the industry. This product is backed by our extensive warranty and world-wide service network. To locate your nearest distributor or service agency, please contact a representative at the address and phone number in your area listed on the inside back cover of this manual, or visit us on the web at www.tweco.com.
This Operating Manual has been designed to instruct you on the correct use and operation of your Tweco® Robotics product. Your satisfaction with this product and its safe operation is our ultimate concern. Therefore, please take the time to read the entire manual, especially the Safety Precautions. They will help you to avoid potential hazards that may exist when working with this product.
YOU ARE IN GOOD COMPANY!
The Brand of Choice for Contractors and Fabricators Worldwide.
Tweco® Robotics is a Global Brand of Arc Welding Products for Thermadyne Industries Inc. We manufacture and supply to major welding industry sectors worldwide including; Manufacturing, Construction, Mining, Automotive, Aerospace, Engineering, Rural and DIY/Hobbyist.
We distinguish ourselves from our competition through market-leading, dependable products that have stood the test of time. We pride ourselves on technical innovation, competitive prices, excellent delivery, superior customer service and technical support, together with excellence in sales and marketing expertise.
Above all, we are committed to develop technologically advanced products to achieve a safer working environment within the welding industry.
Page 3
!
WARNING
READ AND UNDERSTAND THIS ENTIRE MANUAL AND YOUR EMPLOYER’S SAFETY PRACTICES BEFORE INSTALLING, OPERATING, OR SERVICING THE EQUIPMENT.
WHILE THE INFORMATION CONTAINED IN THIS MANUAL REPRESENTS THE MANUFACTURER’S BEST JUDGMENT, THE MANUFACTURER ASSUMES NO LIABILITY FOR ITS USE.
Anti-Spatter Mist Applicator Installation and Operation Guide Instruction Manual Number SM-QRM100
Published by: Tweco® Products Inc. 2800 Airport Road Denton, TX 76208 (940) 566-2000
www.tweco.com
Copyright © 2006 by Thermadyne Industries Inc.
® All rights reserved.
Reproduction of this work, in whole or in part, without written permission of the publisher is prohibited.
The publisher does not assume and hereby disclaims any liability to any party for any loss or damage caused by any error or omission in this Manual, whether such error results from negligence, accident, or any other cause.
Publication Date: July 1, 2006
Record the following information for Warranty purposes:
Where Purchased: ________________________
Purchase Date: ________________________
Equipment Serial #: ________________________
i
Page 4
Anti-spAtter mist ApplicAtor
SECTION 1: SAFETY INSTRUCTIONS AND WARNINGS .......................................... 1-1
1.01 Welding Hazards .......................................................................................1-1
1.02 Principal Safety Standards ........................................................................1-3
1.03 Safety and Health ......................................................................................1-3
SECTION 2: INTRODUCTION AND DESCRIPTION ................................................. 2-4
2.01 How to Use this Manual ............................................................................2-4
2.02 Receipt of Equipment ................................................................................2-4
2.03 Introduction ..............................................................................................2-4
2.04 Standard Features .....................................................................................2-4
SECTION 3: INSTALLATION AND OPERATION ..................................................... 3-6
SECTION 4: REPLACEMENT PARTS ................................................................. 4-8
Table of Contents
STATEMENT OF WARRANTY .........................................................................
WARRANTY SCHEDULE .............................................................................
GLOBAL CUSTOMER SERVICE CONTACT INFORMATION ....................................... 5-11
5-9
5-10
ii
SM-QRM-100
Page 5
Anti-spAtter mist ApplicAtor
!
SECTION 1:
SAFETY INSTRUCTIONS AND WARNINGS
WARNING
SERIOUS INJURY OR DEATH MAY RESULT IF WELDING AND CUTTING EQUIPMENT IS NOT PROPERLY INSTALLED, USED AND MAINTAINED. MISUSE OF THIS EQUIPMENT AND OTHER UNSAFE PRACTICES CAN BE HAZARDOUS. THE OPERATOR, SUPERVISOR AND HELPER MUST READ AND UNDERSTAND THE FOLLOWING SAFETY WARNINGS AND INSTRUCTIONS BEFORE INSTALLING OR USING ANY WELDING OR CUTTING EQUIPMENT.
THE WELDING AND CUTTING PROCESS IS USED IN MANY POTENTIALLY DANGEROUS ENVIRONMENTS SUCH AS ELEVATED HEIGHTS, AREAS OF LIMITED VENTILATION, CLOSE QUARTERS, AROUND WATER, IN HOSTILE ENVIRONMENTS, ETC., AND IT IS IMPORTANT THAT THE OPERATOR(S) ARE AWARE OF THE DANGERS ASSOCIATED WITH WORKING IN THESE TYPES OF CONDITIONS. BE CERTAIN THAT THE OPERATOR(S) ARE TRAINED IN SAFE PRACTICES FOR ENVIRONMENTS IN WHICH THEY ARE EXPECTED TO WORK AND UNDER COMPETENT SUPERVISION.
IT IS ESSENTIAL THAT THE OPERATOR, SUPERVISOR AND ALL OTHER PERSONNEL IN THE WORK AREA ARE AWARE OF THE DANGERS OF THE WELDING OR CUTTING PROCESS. TRAINING AND PROPER SUPERVISION ARE IMPORTANT FOR A SAFE WORK PLACE. KEEP THESE INSTRUCTIONS FOR FUTURE USE. ADDITIONAL RECOMMENDED SAFETY AND OPERATING INFORMATION IS REFERENCED IN EACH SECTION.
1.01 Welding Hazards
WARNING
ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH.
INSTALL AND MAINTAIN EQUIPMENT IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (NFPA 70) AND LOCAL CODES. DO NOT SERVICE OR REPAIR EQUIPMENT WITH POWER ON. DO NOT OPERATE EQUIPMENT WITH PROTECTIVE INSULATORS OR COVERS REMOVED. SERVICE OR REPAIR TO EQUIPMENT MUST BE DONE BY A QUALIFIED REPAIR TECHNICIAN, OR TRAINED PERSONNEL ONLY.
1. Do not touch live electrical parts. Do not touch an electrode with bare skin and electrical
2. ground at the same time.
3. Always keep welding gloves dry and in good condition.
5. All ground connections must be checked periodically to determine that they are mechanically strong and electrically adequate for the required current.
6. When engaged in alternating current, welding, or cutting under wet conditions or warm surroundings where perspiration is a factor, the use of reliable automatic controls for reducing the no-load voltage is recommended to reduce shock hazard.
7. When the welding or cutting process requires values of open circuit voltages in alternating current machines higher than 80 volts, and direct current machines higher than 100 volts, means must be provided to prevent the operator from making accidental contact with the high voltage by adequate insulation or other means.
8. When welding is to be suspended for any substantial length of time, such as during lunch or overnight, all electrodes should be removed from the electrode holder and the electrode holder carefully located so that accidental contact cannot occur.
9. The holder must be disconnected from the power source when not in use.
Never immerse Mig-Guns, electrode holders, tig
10. torches, plasma torches, or electrodes in water.
NOTE
Aluminized protective clothing can become part of the electrical path.
4. Keep oxygen cylinders, chains, wire ropes, cranes, hoists, and elevators away from any part of the electrical path.
SM-QRM-100
SMOKE, FUMES AND GASES CAN BE DANGEROUS TO YOUR HEALTH.
1-1
WARNING
SAFETY INSTRUCTIONS AND WARNINGS
Page 6
Anti-spAtter mist ApplicAtor
11. Keep smoke, fumes, and gases from the breathing area.
12. Fumes from the welding or cutting process are of various types and strengths, depending on the kind of base metal being worked on. To ensure your safety, do not breathe these fumes.
13. Ventilation must be adequate to remove smoke, fumes, and gases during the operation to protect operators and other personnel in the area.
14. Vapors of chlorinated solvents can form the toxic gas “Phosgene” when exposed to ultraviolet radiation from an electric arc. All solvents, degreasers, and potential sources of these vapors must be removed from the work area.
15. Fumes produced by welding or cutting, particularly in confined places, can cause discomfort and physical harm if inhaled over an extended period of time.
16. Provide adequate ventilation in the welding or cutting area. Use air-supplied respirators if ventilation is not adequate to remove all fumes and gases. Never ventilate with oxygen. Oxygen supports and vigorously accelerates fire.
WARNING
ARC RAYS, HOT SLAG AND SPARKS CAN INJURE EYES AND BURN SKIN .
17. The welding and cutting processes produces extreme localized heat and strong ultraviolet rays.
18. Never attempt to weld or cut without a welding helmet with the proper lens. Ensure that the lens complies with federal guidelines. A number 12 to 14 shade filter lens provides the best protection against arc radiation. When in a confined area, prevent the reflected arc rays from entering around the helmet.
19. Ensure all personnel in the work area are protected from arc rays and sparks. Approved shielding curtains and appropriate goggles should be used to provide protection to staff in the surrounding area and operators of nearby equipment.
20. Unprotected skin should also be covered from arc rays, heat and molten metal. Always wear protective gloves and clothing that does not allow skin to become exposed. All pockets should be closed and cuffs sewn shut. Leather aprons, sleeves, leggings, etc., should be worn for out-of­position welding and cutting or for heavy operations using large electrodes. High top work shoes provide adequate protection from foot burns. For added protection use leather spats.
21. Flammable hair preparations should not be used when welding or cutting. Wear ear plugs to protect ears from sparks.
22. Where the work area permits, the operator should be enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide. This is an important factor for absorbing ultraviolet radiations, and lamp black. The operator should be enclosed with non-combustible screens similarly painted.
WARNING
WELDING SPARKS CAN CAUSE FIRES AND EXPLOSIONS.
23. Causes of fire and explosion are: combustibles reached by the arc, flame, flying sparks, hot slag, or heated material. Remove combustibles from the work area and/or provide a fire watch.
24
. Avoid oily or greasy clothing as sparks may ignite them. Have
a fire extinguisher nearby, and know how to use it.
25.
Be alert to the danger of conduction or radiation. For example, if welding or cutting is to be done on a metal wall, partition, ceiling, or roof, precautions must be taken to prevent ignition of combustibles on the other side.
26. Do not w
eld or cut containers that have held combustibles. All hollow spaces, cavities and containers should be vented prior to welding or cutting to permit the escape of air or gases. Purging with inert gas is recommended.
Never use oxygen in a welding torch. Use only inert
27. gases or inert gas mixes as required by the process. Use of combustible compressed gases can cause explosions resulting in personal injury or death. Arcing against any compressed gas cylinder can cause cylinder damage or explosion.
WARNING
NOISE CAN DAMAGE HEARING.
28. Noise from the air carbon-arc process can damage your hearing. Wear protective hearing devices to ensure protection when noise levels exceed OSHA standards. Adequate hearing protection devices must be worn by operators and surrounding personnel to ensure personal protection against noise.
SAFETY INSTRUCTIONS AND WARNINGS
1-2
SM-QRM-100
Page 7
1.02 Principal Safety Standards
!
SAFETY AND OPERATING REFERENCES
1. Code of Federal Regulations. (OSHA) Section 29 Part 1910.95, 132, 133, 134, 139, 251, 252, 253, 254 and 1000. U.S. Government Printing Office, Washington, DC. 20402.
2. ANSl Z49.1 “Safety In Welding and Cutting”.
3. ANSI Z87.1 “Practice for Occupational and Educational Eye and Face Protection”.
4. ANSl Z88.2 “Standard Practice for Respiratory Protection”. American National Standards Institute, 1430 Broadway, New York, NY. 10018.
5. AWS F4.1 “Recommended Safe Practices for Welding and Cutting Containers”.
6. AWS C5.3 “Recommended Practices for Air Carbon-Arc Gouging and Cutting”. The American Welding Society, 550 NW Lejeune RD., P.O.Box 351040, Miami FL. 33135.
7. NFPA 51B “Fire Prevention in Cutting and Welding Processes”.
8. NFPA-7 “National Electrical Code.” National Fire Protection Association, Battery Park, Quincy, MA. 02269.
9. CSA W117.2, “Safety in Welding, Cutting and Allied Processes”. Canadian Standards Association, 178 Rexdale Blvd., Rexdale, Ontario, Canada M9W 1R3.
1.03 Safety and Health
Anti-spAtter mist ApplicAtor
NOTE
Be sure to read and fully comprehend the safety instuctions and warnings contained within section 1 of this manual before performing any welding or cutting operations.
SERIOUS INJURY OR DEATH MAY RESULT IF WELDING AND CUTTING EQUIPMENT IS NOT PROPERLY INSTALLED, USED AND MAINTAINED. MISUSE OF THIS EQUIPMENT, OR OTHER UNSAFE PRACTICES, CAN BE HAZARDOUS.
Electric shock can cause injury or death.
• Smoke, fumes, and gases can be dangerous to your
• health. Arc rays, hot slag, and sparks can injure or burn
• unprotected eyes and skin. Welding sparks can cause fires and explosions.
• Excessive noise can damage your hearing.
SM-QRM-100
WARNING
1-3
SAFETY INSTRUCTIONS AND WARNINGS
Page 8
Anti-spAtter mist ApplicAtor
!
INTRODUCTION AND DESCRIPTION
SECTION 2:
2.01 How to Use this Manual
To ensure safe operation, read the entire manual, including the chapters on safety instructions and warnings.
Throughout this manual, the words WARNING, CAUTION, and NOTE may appear. Pay particular attention to the information provided under these headings. These special annotations are easily recognized as follows:
WARNING
A WARNING GIVES INFORMATION REGARDING POSSIBLE PERSONAL INJURY.
CAUTION
A CAUTION refers to possible equipment damage.
NOTE
A NOTE offers helpful information concerning certain operating procedures.
2.02 Receipt of Equipment
When you receive the equipment, check it against the invoice to make sure it is complete and inspect the equipment for possible damage due to shipping. If there is any damage, notify the carrier immediately to file a claim. Furnish complete information concerning damage claims or shipping errors to the location in your area listed in the inside back cover of this manual. Include a full description of the parts in error.
If you want additional or replacement copies of this CD, please contact Tweco® Robotics at the address and phone number in your area listed on the inside back cover of this manual. Include the Manual number (from page i) and CD part number: 64-2601.
2.03 Introduction
Tweco® Robotics QRM-100 Anti-Spatter Mist Applicator is used to pump a metered amount of Protex® anti­spatter compound to the conductor tube assembly. The application cycle can be applied anytime there are a few spare seconds in the weld cycle, during part changes, or during a cleaning cycle.
The compound is injected into the purge line of the robotic torch and cable assemblies and coats the nozzle, gas diffuser, and tip on the conductor tube. In addition to applying the anti-spatter compound, the compressed air used with the applicators is used to dislodge any loose particles.
The QRM-100 Anti-Spatter Mist Applicator has a 24­volt DC solenoid, which is controlled either by the robot controller or some other type of power source.
2.04 Standard Features
Frequency adjustments from up to 200 pulses per
• minute. Metering device that sets the amount of anti-spatter
• applied with every pulse of the pump. Air Flow Control.
• Output air hose.
• 1-pint reservoir (Optional: 1-quart size).
• Mounting hardware.
QRM-100 Anti-Spatter Applicator
The QRM-100 Anti-Spatter Mist Applicator comes standard with the items shown in Figure 1. Before starting the installa­tion, please read and understand the installation and operation procedures outlined in this manual.
INTRODUCTION AND DESCRIPTION
2-4
SM-QRM-100
Page 9
Anti-spAtter mist ApplicAtor
1
2
3
4
5
6
7
Figure 1: Packaged QRM-100
Item No. Description
1 Anti-spatter Mist Assembly 2 Flat Washer - 3/8” (2 each) 3 Socket Head Cap Screw - (2 each) 4 Flat Washer - #10 (2 each) 5 Hose Clamp 6 Control Cable 7 Hose Assembly
SM-QRM-100
2-5
INTRODUCTION AND DESCRIPTION
Page 10
Anti-spAtter mist ApplicAtor
!
SECTION 3:
INSTALLATION AND OPERATION
1. Remove the QRM-100 Anti-Spatter Mist Applicator from the shipping carton.
2. Check to ensure all items shown in Figure 1 are located and identified. If any of the component parts are missing, please notify the local Tweco Welding Distributor or Tweco Products Customer Service Department at 1-800-426-1888.
3. Place the anti-spatter mist applicator as close to the torch body and cable assembly as possible. This provides the best control of the amount of anti-spatter passing through the assembly.
INSERT 1/4” DIAMETER NYLON TUBE
Figure 3: Compressed Air Connection
AIR SPEED CONTROL
NOTE
The mounting area should allow for integration to the controlling device and air input supply lines. These items should be protected by adequate means if they are subject to welding spatter or other detrimental surroundings.
4. There are two (2) mounting surfaces provided on the unit that allows you to choose the best means to work in your robot cell. Refer to Figure 2 for more complete detail of the units mounting holes.
MOUNTING HOLES
Figure 2: Mounting Hole Locations
5. Secure the mist applicator in place using two 10-24 x 1” long socket head cap screws.
6. Use a 1/4” nylon tube for the compresed air line to the unit, connect the airline to the fitting, and secure. Refer to Figure 3.
7. Connect the control cable to the QRM-100 Mister assembly.
8. Connect the red/white wire of the control cable to the positive (+) side of the DC controller. Connect the green wire to the negative (-) side of the DC controller. Refer to Figure 4.
Figure 4: Control Cable
9. The unit is supplied with a 10ft. (3m) output hose assembly. Press the end with the brass connector into the quick connect fitting on the back of the QRM­100 Mister. Connect the hose to the purge line of the robotic torch body and cable assembly by using the following steps. Refer to Figure 5.
A. Remove the plug from the purge line on the torch
body and cable assembly and slide the steel hose clamp over the line.
B. Insert the hose splice on the output hose
assembly into the purge line.
C. Secure the hose in place using the steel hose
clamp.
PURGE HOSE FROM TORCH
OUTPUT HOSE ASSEMBLY FROM MIST APPLICATIOR
WARNING
NEVER USE OXYGEN WITH THE QRM-100 ANTI­SPATTER MIST APPLICATOR.
NOTE
The air line should be connected to an air regulator capable of delivering 80 to120 psi.
INSTALLATION AND OPERATION
3-6
Figure 5: Purge Line in Place
SM-QRM-100
Page 11
Anti-spAtter mist ApplicAtor
10. Fill the reservoir with the Protex® Select Anti-Spatter Compound. A minimum of 3 ounces must be in the reservoir at all times. Refer to Figure 6.
IMPORTANT: Be sure the air vent is “OPEN” before operating the Anti-Spatter Mist Applicator as shown in Figure 6.
AIT VENT
3 OUNCES AT ALL TIMES
Figure 6: Callout in Reservoir
11. Turn on the air supply, regulated to 80 to 120 psi, to the unit.
12. Set the pulse adjustment to the maximum setting of 200 pulses per minute by rotating the adjustment screw clockwise until it stops. Refer to Figure 7.
PULSE ADJUSTMENT
Figure 7: Pulse Adjustment
13. Turn the air flow adjustment screw to deliver the maximum flow, by rotating the control valve knob counter-clockwise until it stops. Refer to Figure 8.
14. Set the volume adjustment knob all of the way clockwise. The control knob must be pulled out to allow this adjustment to be completed. Refer to Figure 9.
VOLUME CONTROL KNOB
Figure 9: Volume Control Knob
15. Located on the output side of the unit is an access hole allowing the unit to be manually purged. Insert a round object through the hole to activate the solenoid valve by pressing the small button inward.
16. Hold the solenoid valve open until anti-spatter compound can be seen coming out of the nozzle. This procedure will saturate both the output air hose and the torch body and cable assembly purge line.
17. Reset the pulse generator to about 25 pulses per minute and adjust the airflow as needed.
18. Adjust the volume adjustment knob to obtain the desired amount of compound residue coverage on the nozzle, tip and diffuser by rotating counter clockwise.
19. Turn off the signal.
20. Activate the designated output to the unit at the desired position in the welding program to use the unit in an automatic cycle.
21. Monitor the welding process to verify that the proper amount of anti-spatter compound is being supplied to prevent weld spatter buildup in the nozzle, tip and diffuser area.
22. If more anti-spatter is required, increase the number of pulses or volume of the anti-spatter compound.
SM-QRM-100
AIR SPEED CONTROL VALVE
Figure 8: Air Speed Control valve
3-7
INSTALLATION AND OPERATION
Page 12
Anti-spAtter mist ApplicAtor
1
2
5
4
6
11
7
9
10
8
3
REPLACEMENT PARTS
SECTION 4:
Item
No.
1 QRC-417 3500-1226 One Pint Reservoir (Standard) 2 QRM-122 3500-1413 Cover Assembly with Screws (4 each) 3 QRM-3Q 3500-1415 Air Fitting - 1/8” NPT - 1/4” Tube Straight Fitting 4 QRM-100MK 3500-1407 Mounting Hardware 5 QRM-142 3500-1409 Solenoid Valve 6 QRM-109 3500-1414 Hose Clamp (5 each) 7 QRM-101 3500-1410 Air Flow Control 8 QRM-112 3500-1406 Servo Meter with Standoffs and O-rings
9 QRM-141 3500-1412 Circuit Board 10 QRM-108 3500-1408 Purge Hose 11 QRM-143 3500-1411 Control Cable
Part No. Stock No. Description
REPLACEMENT PARTS
4-8
SM-QRM-100
Page 13
Anti-spAtter mist ApplicAtor
STATEMENT OF WARRANTY
LIMITED WARRANTY: THERMADYNE® warrants that its products will be free of defects in workmanship or material. Should any failure to conform to this warranty appear within the time period applicable to the THERMADYNE products as stated below, THERMADYNE shall, upon notification thereof and substantiation that the product has been stored, installed, operated, and maintained in accordance with THERMADYNE’s specifications, instructions, recommendations and recognized standard industry practice, and not subject to misuse, repair, neglect, alteration, or accident, correct such defects by suitable repair or replacement, at THERMADYNE’s sole option, of any components or parts of the product determined by THERMADYNE to be defective.
THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
LIMITATION OF LIABILITY: THERMADYNE shall not under any circumstances be liable for special or consequential
damages, such as, but not limited to, damage or loss of purchased or replacement goods, or claims of customers of distributor (hereinafter the “Purchaser”) for service interruption. The remedies of the Purchaser set forth herein are exclusive and the liability of THERMADYNE with respect to any contract, or anything done in connection therewith such as the performance or breach thereof, or from the manufacture, sale, delivery, resale, or use of any goods covered by or furnished by THERMADYNE whether arising out of contract, negligence, strict tort, or under any warranty, or otherwise, shall not, except as expressly provided herein, exceed the price of the goods upon which such liability is based.
THIS WARRANTY BECOMES INVALID IF REPLACEMENT PARTS OR ACCESSORIES ARE USED WHICH MAY IMPAIR THE SAFETY OR PERFORMANCE OF ANY THERMADYNE PRODUCT.
THIS WARRANTY IS INVALID IF THE PRODUCT IS SOLD BY NON-AUTHORIZED PERSONS.
This warranty is effective for the time stated in the Warranty Schedule beginning on the date that the authorized distributor delivers the products to the Purchaser.
Warranty repairs or replacement claims under this limited warranty must be submitted by an authorized THERMADYNE repair facility within thirty (30) days of the repair. No transportation costs of any kind will be paid under this warranty. Transportation charges to send products to an authorized warranty repair facility shall be the responsibility of the Purchaser. All returned goods shall be at the Purchaser’s risk and expense. This warranty supersedes all previous THERMADYNE warranties.
SM-QRM-100
5-9
Page 14
WARRANTY SCHEDULE
The warranty is effective below for the time stated in the Warranty Schedule beginning on the date that the authorized distributor delivers the products to the purchaser. THERMADYNE® reserves the right to request documented evidence of date of purchase.
Engine Driven Welders Parts / Labor
Original Main Power Stators and Inductors 3 years / 3 years Original Main Power Rectifiers, Control P.C. Boards 3 years / 3 years All Other Original Circuits and Components Including, but not Limited to, Relays, Switches, Contactors, Solenoids, Fans, Power Switch Semi-Conductors 1 year / 1 year Engines and Associated Components are NOT Warranted by Thermal Arc®, Although Most are Warranted by the Engine Manufacturer. SEE THE ENGINE
MANUFACTURERS’ WARRANTY FOR DETAILS.
Fabricator® 131, 181, 190, 210, 251, 281; Fabstar® 4030; PowerMaster® 350, 350P, 500, 500P; Excel-Arc® 6045; Wire Feeders: Ultrafeed®, Porta-feed®
Original Main Power Transformer and Inductor 5 years / 3 years Original Main Power Rectifiers, Control P.C. Boards, Power Switch Semi-Conductors 3 years / 3 years All Other Original Circuits and Components Including, but not Limited to, Relays, Switches, Contactors, Solenoids, Fans, Electric Motors 1 year / 1 year
160TS, 300TS, 400TS, 185AC/DC, 200AC/DC, 300AC/DC, 400GTSW, 400MST, 300MST, 400MSTP
Original Main Power Magnetics 5 years / 3 years Original Main Power Rectifiers, Control P.C. Boards, Power Switch Semi-Conductors 3 years / 3 years All Other Original Circuits and Components Including, but not Limited to, Relays, Switches, Contactors, Solenoids, Fans, Electric Motors 1 year / 1 year
Original Main Power Magnetics 5 years / 3 years Original Main Power Rectifiers, Control P.C. Boards, Power Switch Semi-Conductors 3 years / 3 years Welding Console, Weld Controller, Weld Timer 3 years / 3 years All Other Original Circuits and Components Including, but not Limited to, Relays, Switches, Contactors, Solenoids, Fans, Electric Motors, Coolant Recirculators 1 year / 1 year
Original Main Power Magnetics 1 year / 1 year Original Main Power Rectifiers, Control P.C. Boards 1 year / 1 year All Other Original Circuits and Components Including, but not Limited to, Relays, Switches, Contactors, Solenoids, Fans, Power Switch Semi-Conductors 1 year / 1 year
Original Main Power Magnetics 5 years / 3 years Original Main Power Rectifiers, Control P.C. Boards 3 years / 3 years All Other Original Circuits and Components Including, but not Limited to, Relays, Switches, Contactors, Solenoids, Fans, Power Switch Semi-Conductors 1 year / 1 year
Water Recirculators 1 year / 1 year Plasma Welding Torches 180 days / 180 days Gas Regulators (Supplied with Power Sources) 180 days / NA MIG and TIG Torches (Supplied with Power Sources) 90 days / NA Replacement Repair Parts 90 days / NA MIG, TIG and Plasma Welding Torch Consumable Items NA / NA
Victor® Professional 5 years / NA Oxygen Conservers 2 years / NA Aluminum Cylinders Lifetime / NA Cutting Machine Motors 1 year / NA HP&I Brass Regulators/Manifolds 2 years / NA HP&I Stainless Regulators/Manifolds 1 year / NA HP&I Corrosive Gas Regulators/Manifolds 90 days / NA TurboTorch® 3 years / NA CutSkill® 2 years / NA Steel Cylinders 1 year / NA Victor Medical 6 years / NA Victor VSP 2 years / NA Firepower® MIG Welders 5-2-1 years / NA Transformers 5 years / NA Parts Used in Rental Applications 1 year from date sold by seller to authorized
Arcair® N6000 90 days / NA Eliminator® Spool and Pull Guns 90 days / NA Robotic Deflection Mounts 90 days / NA QRM-100 Anti-Spatter Applicator 90 days / NA TC and TCV Water Coolers 1 year / NA TSC-96 Smoke Collector 1 year / NA ESG-1, EPG-CR1, EPG-CR2 Control Boxes for Eliminator Spool & Pull Guns 1 year / NA QRC-2000 Nozzle Cleaning Stations 1 year / 1 year All other products 30 days from date purchaser purchases from seller. 30 days / NA
Automated Plasma 2 years / 1 year CutMaster™ 3 years / 3 years PakMaster® XL PLUS 3 years / 1 year Drag-Gun® 1 year / 1 year Drag-Gun Plus 2 years / 1 year Torches 1 year / 1 year Consoles, Control Equipment, Heat Exchangers and Accessory Equipment 1 year / 1 year
GTAW (TIG) & Multi-process Inverter Welding Equipment Parts / Labor
Scout®, Raider®, Explorer™
See the Engine Manufacturers’ Warranty
GMAW/FCAW (MIG) Welding Equipment Parts / Labor
Plasma Welding Equipment Parts / Labor
Ultima® 150
SMAW (Stick) Welding Equipment Parts / Labor
Dragster™ 85
160S, 300S, 400S
General Arc Equipment Parts / Labor
Gas Welding and Cutting Equipment Parts / Labor
MIG Torches and Arc Accessories Parts / Labor
Plasma Cutting Systems Parts / Labor
for Details
distributor
Page 15
GLOBAL CUSTOMER SERVICE CONTACT INFORMATION
Thermadyne USA
2800 Airport Road Denton, TX 76207 USA Telephone: (1) 800-426-1888 Fax: (1) 800-535-0557
Thermadyne Canada
2070 Wyecroft Road Oakville, Ontario Canada, L6L5V6 Telephone: (1) 905-827-9777 Fax: (1) 905-827-9797
Thermadyne Europe
Europe Building Chorley North Industrial Park Chorley, Lancashire England, PR6 7Bx Telephone: (44) 1257-261755 Fax: (44) 1257-224800
Thermadyne Asia Sdn Bhd
Lot 151, Jalan Industri 3/5A Rawang Integrated Industrial Park - Jln Batu Arang 48000 Rawang Selangor Darul Ehsan West Malaysia Telephone: 603+ 6092 2988 Fax : 603+ 6092 1085
Cigweld Australia
71 Gower Street Preston, Victoria Australia, 3072 Telephone: 1300-654-674 Fax: 613+ 9474-7391
Thermadyne Italy
OCIM, S.r.L. Via Benaco, 3 20098 S. Giuliano Milan, Italy Tel: (39) 02-98 80320 Fax: (39) 02-98 281773
Thermadyne China
RM 102A 685 Ding Xi Rd Chang Ning District Shanghai, PR, 200052 Telephone: 86 21+6280-1273 Fax: 86 21+3226-0955
Thermadyne International
2070 Wyecroft Road Oakville, Ontario Canada, L6L5V6 Telephone: (1) 905-827-9777 Fax: (1) 905-827-9797
Page 16
World Headquarters
Thermadyne Holdings Corporation Suite 300, 16052 Swingley Ridge Road St. Louis, MO 63017 Telephone: (636) 728-3000 Fascimile: (636) 728-3010 www.thermadyne.com
Loading...