Turbo Air TAS-18EHN User Manual

4184 E. Conant St. Long Beach, CA 90808 Tel. 888-900-1002 Fax. 310-900-1088
www.turboairinc.net
DC Inverter Wall Mount Unit
Project :
Item # : Qty :
Approval :
Model : TAS-18EHN - TAS-18EHN/O
208~230V / 60HZ (Evaporator Unit & Condensing Unit) HEAT PUMP
Low Ambient Operation
The unit can set for cooling even when the outdoor temperature drops to 5 degrees F. This is ideal for locations that require cooling even in winter.
Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.
Quiet Operation
The DC Inverter Air Conditioner uses a twin rotary compressor. Compared to the conventional single cylinder type, the twin rotary compressor dramatically reduces vibration and noise during operation, thus ensuring quiet operation.
Energy-Saving Operation
The DC Inverter Air Conditioner affords continuous operation, while it adjusts capacity according to the room temperature. The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures efficient, economical operation.
R-410A
ODP(Ozone Depletion Potential) = 0 of hfc refrigerant is used.
Air Sweep Control (Selected model)
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.
Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cool blast at the beginning while the heat pump is warming up. (Heat pump unit only)
Rapid Cooling and Heating
Since the DC Inverter Air Conditioner has efficient rapid heating and cooling capacity produced by variable compressor rotation speed, it ensures quicker control of room temperatures than conventional air conditioners.
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve.
Louver Control
Louver can be manually set to the desired angle by remote control.
Anti-Mold Filter
Filter is treated with anti-mold chemicals to prevent mold or bacteria from occurring.
Ver.201405
1 YEAR
( U.S.A only
)
DC Inverter Wall Mount Unit
JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE APPROVAL CONSTRUCTION
SPECIFICATIONS
SEER EER HSPF Voltage Breaker Size (A) RLA Cool/Heat (A) Operating Ambient Temperature Range for Cooling Operating Ambient Temperature Range for Heating
Indoor Unit
Airlow Hi/Medium/Low Speed (CFM) Noise Level Hi Speed (Db) Width (Inches) Depth (Inches) Height (Inches) Unit Weight (lbs)
Outdoor Unit
Noise Level (dB) Width (Inches) Depth (Inches) Height (Inches) Unit Weight (lbs)
TAS-18EHN & TAS-18EHN/O
21
12.5
9.5
208-230V/60HZ/1PHASE
20
6.5/6.7 5'F - 125'F 5'F - 125'F
1200/950/750
47
41.93
11.81
15.75
26.46
60
37.99
15.55
29.72
102.51
Line Sets
Refrigerant Pipe Size Maximum Length Maximum Vertical Factory Charge for (Ft) Additional Charge (Oz/Ft)
Controls
Control Method Communication Control Voltage
Certification
Safety Performance
*All specification subject to change without notice.
1 YEAR
(
)
U.S.A only
R410A
1/4"/1/2"
66 26
Wired & wireless remote control with temp sensor in indoor unit
208-230V
ETL
ARI 3081765
Toll Free : 888-900-1002
Loading...