DC Inverter Wall Mount Unit
Project :
Model # :
Item # : Qty :
Approval :
Model : TAS-09EHU - TAS-09EHU/O
115V / 60HZ (Evaporator Unit & Condensing Unit) HEAT PUMP
Low Ambient Operation
The unit can set for cooling even when the outdoor temperature
drops to 5 degrees F. This is ideal for locations that require
cooling even in winter.
Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation
at its preset program, after power is restored from a power failure.
Quiet Operation
The DC Inverter Air Conditioner uses a twin rotary compressor.
Compared to the conventional single cylinder type, the twin rotary
compressor dramatically reduces vibration and noise during
operation, thus ensuring quiet operation.
Energy-Saving Operation
The DC Inverter Air Conditioner affords continuous operation,
while it adjusts capacity according to the room temperature. The
accurate sensing of cooling or heating loads prevents frequent
changes in capacity and ensures efficient, economical operation.
R-410A
ODP(Ozone Depletion Potential) = 0 of hfc refrigerant is used.
Air Sweep Control (Selected model)
The air sweep function moves the louver up and down in the air
outlet, directing air in a “sweeping” motion around the room and
providing comfort in every corner.
Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start
Heating System prevents any cool blast at the beginning while
the heat pump is warming up. (Heat pump unit only)
Rapid Cooling and Heating
Since the DC Inverter Air Conditioner has efficient rapid heating
and cooling capacity produced by variable compressor rotation
speed, it ensures quicker control of room temperatures than
conventional air conditioners.
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse
type electric control valve.
Louver Control
Louver can be manually set to the desired angle by remote
control.
Anti-Mold Filter
Filter is treated with anti-mold chemicals to prevent mold or bacteria
from occurring.
Ver.201405
1 YEAR
(
U.S.A only
)
![](/html/70/7030/70308d9397abd2995ee16e5f5eefbfb29a05de3598f5b591c64257f28c486673/bg2.png)
DC Inverter Wall Mount Unit
JOB NAME: LOCATION:
PURCHASER:
ENGINEER:
SUBMITTED TO: FOR: REFERENCE APPROVAL CONSTRUCTION
SPECIFICATIONS TAS-09EHU / TAS-09EHU/O
SEER 16
EER 12
HSPF 8.5
Voltage 115V/60HZ/1PHASE
Breaker Size (A) 20
RLA Cool/Heat (A) 4.4
Operating Ambient Temperature Range for Cooling 5'F - 125'F
Operating Ambient Temperature Range for Heating 5'F - 125'F
Indoor Unit
Airlow Hi/Medium/Low Speed (CFM) 500/420/380
Noise Level Hi Speed (Db) 42
Width (Inches) 31.5
Depth (Inches) 7.5
Height (Inches) 11
Unit Weight (lbs) 22
Outdoor Unit
Noise Level (dB) 55
Width (Inches) 31.3
Depth (Inches) 10
Height (Inches) 21.3
Unit Weight (lbs) 66
Line Sets
Refrigerant R410A
Pipe Size 1/4" 3/8"
Maximum Length 82
Maximum Vertical 33
Factory Charge for (Ft) 25
Additional Charge (Oz/Ft) 0.2
Controls
Control Method Wired & wireless remote control with temp sensor in indoor unit
Communication Control Voltage 12
Certification
Safety UL
Performance ARI 3081763
*All specification subject to change without notice.