Turbo Air TAS-09EHU User Manual

4184 E. Conant St. Long Beach, CA 90808 Tel. 888-900-1002 Fax. 310-900-1088
www.turboairinc.net
DC Inverter Wall Mount Unit
Project :
Item # : Qty :
Approval :
Model : TAS-09EHU - TAS-09EHU/O
115V / 60HZ (Evaporator Unit & Condensing Unit) HEAT PUMP
Low Ambient Operation
The unit can set for cooling even when the outdoor temperature drops to 5 degrees F. This is ideal for locations that require cooling even in winter.
Automatic Restart Function after Power Failure
This feature allows the system to automatically resume operation at its preset program, after power is restored from a power failure.
Quiet Operation
The DC Inverter Air Conditioner uses a twin rotary compressor. Compared to the conventional single cylinder type, the twin rotary compressor dramatically reduces vibration and noise during operation, thus ensuring quiet operation.
Energy-Saving Operation
The DC Inverter Air Conditioner affords continuous operation, while it adjusts capacity according to the room temperature. The accurate sensing of cooling or heating loads prevents frequent changes in capacity and ensures efficient, economical operation.
R-410A
ODP(Ozone Depletion Potential) = 0 of hfc refrigerant is used.
Air Sweep Control (Selected model)
The air sweep function moves the louver up and down in the air outlet, directing air in a “sweeping” motion around the room and providing comfort in every corner.
Hot Start Heating System
Right from the start, air is warm and comfortable. The Hot Start Heating System prevents any cool blast at the beginning while the heat pump is warming up. (Heat pump unit only)
Rapid Cooling and Heating
Since the DC Inverter Air Conditioner has efficient rapid heating and cooling capacity produced by variable compressor rotation speed, it ensures quicker control of room temperatures than conventional air conditioners.
Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse type electric control valve.
Louver Control
Louver can be manually set to the desired angle by remote control.
Anti-Mold Filter
Filter is treated with anti-mold chemicals to prevent mold or bacteria from occurring.
Ver.201405
1 YEAR
( U.S.A only
)
DC Inverter Wall Mount Unit
JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE APPROVAL CONSTRUCTION
SPECIFICATIONS TAS-09EHU / TAS-09EHU/O
SEER 16 EER 12 HSPF 8.5 Voltage 115V/60HZ/1PHASE Breaker Size (A) 20 RLA Cool/Heat (A) 4.4 Operating Ambient Temperature Range for Cooling 5'F - 125'F Operating Ambient Temperature Range for Heating 5'F - 125'F
Indoor Unit
Airlow Hi/Medium/Low Speed (CFM) 500/420/380 Noise Level Hi Speed (Db) 42 Width (Inches) 31.5 Depth (Inches) 7.5 Height (Inches) 11 Unit Weight (lbs) 22
Outdoor Unit
Noise Level (dB) 55 Width (Inches) 31.3 Depth (Inches) 10 Height (Inches) 21.3 Unit Weight (lbs) 66
Line Sets
Refrigerant R410A Pipe Size 1/4" 3/8" Maximum Length 82 Maximum Vertical 33 Factory Charge for (Ft) 25 Additional Charge (Oz/Ft) 0.2
Controls
Control Method Wired & wireless remote control with temp sensor in indoor unit Communication Control Voltage 12
Certification
Safety UL Performance ARI 3081763
*All specification subject to change without notice.
1 YEAR
( U.S.A only
)
Toll Free : 888-900-1002