Combustion Analysis
TSI’s Series CA-6100 CA-C
ALC
portable
combustion analyzers are ideal for light
commercial to residential applications. Boiler
service professionals are provided flue gas data
to tune burners on furnaces, boilers and other
heating appliances for safe, efficient operation.
Models with O
2
, stack temperature and
ambient temperature have user-selectable fuels,
calculated CO
2
, efficiency and excess air.
Options measure CO and draft pressure.
Features
• Industry-leading service
• Large display and intuitive operation
• Real-time data provides quick tuning feedback
• 10-hour battery life lowers operating costs
• Automatic baseline calibration of sensors
• Recalibrates easily for critical safety checks
• Quick new sensor installation
• Heavy-duty pump designed for field service
Series CA-6100 CA-CALC
TM
Combustion Analyzers
Applications
• Tune boilers, furnaces and appliances for
optimum efficiency and safety
• Check building combustion ventilation
• Check CO safety of appliances
• Monitor burner performance
• Supplement preventative maintenance
Models available for:
• Boiler/Burner Service and Repair Contractors
• Boiler/Furnace Maintenance Companies
• Building Contractors
• Commercial Boiler Owners
• Boiler Manufacturers
• Plant Engineers
• School and Office Maintenance Staff
• Utility Companies
P/N 2980190 4/02 Copyright © 2002 by TSI Incorporated Printed in U.S.A.
TSI Incorporated
500 Cardigan Road , Shoreview, MN 55126 USA
Tel: 651 490 2711 Toll Free: 1 800 777 8356 Fax: 651 490 2874 E-mail: answers@tsi.com
TSI Germany—Tel: +49-241-523030 Fax: +49-241-5230349 E-mail: tsigmbh@tsi.com
TSI Sweden—Tel: +46-18-52-70-00 Fax: +46-18-52-70-70 E-mail: tsi@tsi.se
Operating Conditions:
Instrument Temperature Range:
Operating Range:
32 to 113°F (0 to 45°C)
Storage Range: -20 to 122°F (-30 to 50°C)
Instrument Humidity Range:
Continuous:
15 to 90% non-condensing
Intermittent: 0 to 99%
Maximum Flue Gas Probe Temperature:
Continuous:
1,292°F (700°C)
(handle shielded)
General Data:
Instrument:
External Dimensions:
4.5 × 7.5 × 2.5 in. (11.4 × 19.1 × 6.4 cm)
Weight: 1.2 lbs/1.4 lbs with probe (0.54/0.64 kg)
Display: LCD
Pump:
Flow Rate:
Nominal 0.8 lpm
Maximum Flue Pressure: ±30 in. H2O (±80 mBar)
Standard Flue Gas Sampling Probe:
Probe/Hose Material:
Stainless steel/rubber
Probe Length: 12 in. std (30 cm)
Hose Length: 7 ft (2.13 m)
Probe Diameter: 3/16 in. (0.48 cm)
Communication Interface:
Type:
Serial
Baud Rate: 1,200 to 19,200 selectable
Power Requirements:
Batteries:
4 size AA alkaline batteries
Battery Life: >10 hours (pump on)
AC Adapter (optional): P/N 2613033
Backup Battery: Lithium
Backup Battery Life: 3 yrs
Sensors:
Oxygen (O2)*:
Range:
0 to 25%
Resolution: 0.1% O
2
Carbon Monoxide (CO)*:
Range:
0 to 2,000 ppm
Resolution: 1 ppm
Flue Gas Temperature Probe:
Range:
32 to 1,292°F (0 to 700°C)
Resolution: 1°F (1°C)
Draft Pressure:
Range:
±30 in. H2O (±80 mBar)
Resolution: 0.01 in. H2O (0.01 mBar)
Supply Air Temperature Probe (Optional)**:
Range:
-40 to 392°F (-40 to 150°C)
Resolution: 1°F (1°C)
Calculated Data:
Carbon Dioxide (CO2)—Calculated from O2and fuel type:
Range:
0 to CO2Max
Excess Air (EA):
Range:
0 to 1,000%
Loss ASME:
Range:
-25 to 100%
Efficiency ASME (net):
Range:
0 to 125%
Loss qA (Siegert):
Range:
-25 to 100%
Efficiency (η) based on qA:
Range:
0 to 125%
Lambda (λ):
Range:
0 to 11
CO Air Free:
Range:
0 to 20% (10,000 ppm=1%)
CO/CO2Index:
Range:
0 to 1.000
Series CA-6100 CA-CALC Combustion Analyzers
Specifications
* Electrochemical sensor
** P/N 3013033
Specifications are subject to change without notice.
* Calculated from fuel type and O
2
Ordering
Information
)
2
∆T)
)*
2
λ)
Index
2
Model
CA-6110
CA-6120
CA-6130
CA-6140
Carbon Monoxide (CO)
Draft Differential Pressure
Ambient, Stack Temp. (
Oxygen (O
Carbon Dioxide (CO
•
•
•
•
•
•••
•
•
•
•
•
•
CO/CO
Efficiency (Loss) (qA)
Excess Air (
CO Air Free (Undiluted)
•
•••
•
•
•
•
•
•
•
Water Trap and Filter
Data Storage/Review/Print
7 Factory-Default and
•
•
•
•
•
•
•
•
•
•
•
For current information
www.tsi.com
1 User-Defined Fuel