Trumeter 898X Data Sheet

Model 898X
Electronic Programmable LCD Preset Counter and Rate Indicator
max.35 [1.38]
7.35 [0.29]
11.2 [0.44]
]
48 [1.88]
96 [3.77]
90 [3.54]
]
+0.024
[1.77
+0.6
45
43 [1.69]
90.5 [3.56]
+0.8
92
[3.622
+0.031
The 898X is a counter, tachometer, timer and position display in a single unit. It can be used as a preset counter, batch counter or totalizer depending on requirements, with automatic help text to take the user through programming. With its
automatic help text, clearly and legibly displayed on 14 LED segments, the 898X preset counter takes the user e󰀨ortlessly
through the programming. The large user-friendly front keys can be operated even when wearing gloves. The 14mm high LED display ensures easy reading even from a long distance and in poor lighting conditions.
Available with RS485 interface and MODBUS and CR/LF protocol
Key Fetatures Benefits
• Counter, tachometer, timer and position display in one
counter
• Can be used as a preset counter, batch counter or total
counter
• 2 relays (change-over)
• Many different count models
• Scalable display
• Set value, step to tracking preset
• Multi-range power supply for AC
Modbus or CR/LF protocol
• Allows for direct connection of a large display or Printer
• Automatic help text
• 14-segment LED for improved text representation
• Status display of the presets
• 3 defined parameters
• Tracking presets eliminate the need for re-programming the
pre-signal
• 4-stage RESET modes
• 3-stage keypad locking
• Suitable for installation in mosaic systems
Specications
General Technical Data
Display 6-digit red 14 segment LED display, 14mm [0.55] high
Operating Temperature -20ºC - +65ºC [-4ºF - +149ºF] (non-condensing)
Storage Temperature -25ºC - +5ºC [-13ºF - +167ºF]
Relative humidity (at +40ºC [+104ºF]) RH 93% (non-condensing)
Altitude up to 2000m [6562’]
Electrical characteristics
Power Supply AC 100-240 VAC, +10% max. 11 VA, 50/60 Hz
External Fuse Protection 230 VAC T0.1 A 10-30 VDC T 0.25 A
Data Retention >10 years, EEPROM
Response time of the frequency meter 100 / 600 ms (details in instruction manual)
Input Modes Count Direction (cnt.dir),
Pulse Counter: Di󰀨erence (up.dn)
Addition A+B (up.up)
Phase discriminator x1, x2, x4 (quad, quad x2, quad x4),
Ratio (A/B),
Ratio in % ((A-B)/Ax100%)
Frequency Meter: A, A-B, A+B quad, A/B, (A-B)/A x 100%
Timer: 4 start modes: FrErun, Auto, InpA.InpB., InpB.InpB.
Sensor power supply AC supply: 24V DC+ 15%, 80 mA
DC Supply: max. 80 mA, external power supply is connected through
EMC Emitted interference: EN55011 class B
Immunity to interference: EN 61000-6-2
Device safety Designed to EN 61010 part 1
Protected class 3
Application Area Pollution level 2
Mechanical Data
Protection IP65 (from the front)
Weight approx. 180g [6.35 oz]
Count inputs A and B
Polarity of the inputs programmable for all inputs in common, NPN/PNP
Input resistance 5kΩ
Count frequency Pulse counters: max. 55kHz
Tachometers: max. 65 kHz
Can be damped to 30 Hz (mechanical contacts) (details in instruction manual)
Control/Reset input MPI 1 and MPI 2, Lock, Gate, Reset
Min pulse duration of the inputs 10 ms/1ms
Switching levels with AC supply 4-30 VDC Low: 0 … 2 VDC
High 3.5 … 30 VDC
Switching levels with DC supply 1-30 VDC Low: 0 … 2 VDC
High: 3.5 … 30 VDC
Pulse shape variable, Schmitt-Trigger characteristics
Outputs
Switching voltage max. 250 VAC / 150 VDC
Switching current max . 3 A AC / DC
min. 30 mA DC
Switching capacity max. 750 VA / 90 W
Output 1 + 2
Mech. Service life (switching cycles) 2 x 10⁷
No. of switching cycles at 3 A / 250 VAC 5 x 10⁴
No. of switching cycles at 3 A / 30 VDC 5 x 10⁴
Relay with changeover contact
Reaction time of the outputs 13ms
(pulse / time) (details in instruction manual)
Optional interface MODBUS and CR/LF
Count Frequency max. 45 kHz 9 (details in instruction manual)
Interface RS232, RS485
Baud Rate 9600
Device address 1-99, programmable
Functions / Count Modes
Pulse Counter • Count with direction mode
• Difference mode
• Quadrature mode quad / quad2 /
quad4
• Add, sub, automatic reset
• 2-input adding mode A+B
• Ratio measurement A/B
• Multi-range power supply for AC or
DC
Frequency Meter (tachometer) • A
• A - B
• A + B
• A / B
• (A – B) / A x 100% (percentage
display)
• Quad (phase discriminator with
recognition of direction)
• Percentage difference
measurement (A/B) / A x 100%
• Batch counting
• Totaliser (overall total)
• Multiplication and division factor
(up to 99.9999)
• Set value
• Step or tracking preset
• Averaging
• Start delay
• 2nd tacho input
• Gate input
• Multiplication and division factor
(up to 99.9999)
Time and hours-run Meter (timer) • FrErun (control via gate input)
• Auto (start via reset, stop at
preset)
• InpB.InpB (start with the first edge
at InpB (stop with second edge
InpB.)
Part Numbers
8980-1: Dual Preset, Dual Relay Counter, 10-30VDC
8981-1: Dual Preset, Dual Relay Counter, 100-240VAC
8981-5: Dual Preset, Dual Relay Counter, 100-240VAC, RS485
• InpA.InpB (start w/ InpA., stop w/
inpB.)
• Totaliser (overall total)
• Batch counting
• Set value
• Step or tracking preset
Loading...