The use of upright gas cylinders from which gas is taken in
the gas phase is mandatory for the operation of gas regula-
tors, gas equipment and gas systems. Gas cylinders from
which gas is taken in the liquid phase (e.g. for fork lifts) must
not be used, since they would result in damage to the gas
system.
In event of leaks in the gas system or if there is a smell of gas:
Items sensitive to heat (e.g. spray cans) must not be stored
in the installation area, since excess temperatures may under
circumstances be incurred there.
Only pressure control equipment that complies with EN 12864
(in vehicles) with a fixed delivery pressure of 30 mbar must be
used for the gas system. The flow rate of the pressure control
device must correspond to at least the maximum consumption of all devices installed by the system manufacturer.
extinguish all naked flames
–
do not smoke
–
switch off all appliances
–
shut off the gas cylinder
–
open the windows and doors
–
do not actuate any electrical switches
–
have the entire system checked by an expert!
–
Repairs may only be carried out by an expert.
During use, please observe the regulations of EN 60335-1:2010,
according to which this device has not been designed for use
by people (including children) who have restricted physical,
sensory or mental abilities or a lack of experience and / or
knowledge, unless they are supervised by a person responsible for their safety or have received instructions from that
person as to how the device is to be used.
Children should be supervised to ensure they do not play with
the device.
To avoid risk caused by unintentional resetting of the
overtemperature sensor, the device may not be supplied
via an external switching device, such as a timer, or be connected with a circuit that is regularly switched on and off by
any kind of equipment.
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
modifications to the unit (including accessories),
–
modifications to the exhaust duct and the cowl,
–
failure to use original Truma parts as replacement parts and
–
accessories,
failure to follow the installation and operating instructions.
–
It also becomes illegal to use the appliance, and in some
countries this even makes it illegal to use the vehicle.
The operating pressure for the gas supply (30 mbar) must correspond to the operating pressure of the appliance (see data
plate).
Liquid gas systems must accord with the technical and
administrative regulations of the particular country in which
they are being used (e.g. EN 1949 for vehicles). National
regulations must be respected.
Important operating notes
If the cowl has been placed near or directly beneath an opening window, the device must be equipped with an automatic
shut-off device in order to prevent operation with the window
open.
Always mount the cowl cap if the water heater is not being
used. Non-observance of this point can lead to the function of
the appliance being impaired through water, dirt or insects.
Before setting off on any journey, fit cowl cap with the
boiler switched off. Please ensure that it is secure and
has locked into place (risk of accident). Defective cowl caps
must not be used.
There shall be no claim under guarantee if this point is not
observed. Always remove the cowl cap prior to operating the
water heater!
If just the cold water system is being used, without water
heater, the heater tank is also filled up with water. In order
to avoid damage through frost, the water contents must be
drained by actuating the safety/drain valve, also when the
heater has not been used. As an alternative, two shut-off
valves, resistant to hot water, can be fitted in front of the cold
and hot water connection.
Drain the water heater if there is a risk of frost! There
shall be no claim under guarantee if this point is not
observed.
If connecting to a central water supply (rural or city connection) or when using more powerful pumps, a pressure reducer
must be used which prevents pressures of greater than 2.8 bar
occurring in the Ultrastore.
The testing of the gas system must be repeated every two years by a qualified specialist and, if appropriate, confirmed
on the inspection certificate.
The vehicle owner is always responsible for arranging
the inspection.
Liquid gas equipment must not be used when refuelling,
in multi-storey car parks, in garages or on ferries.
During the initial operation of a brand new appliance (or after
it has not been used for some time), a slight amount of fumes
and a slight smell may be noticed for a short while. Remedial
action here is to immediately run the heater and to ensure adequate room ventilation.
If the burner makes an unusual noise or if the flame lifts off,
it is likely that the gas pressure regulator is faulty and it is
essential to have it checked.
4
Operating instructions
Always observe the operating instructions prior to
starting! The vehicle owner is responsible for the correct
operation of the appliance.
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the
appliance, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if necessary.
Before using the first time, it is essential to flush the
entire water supply through with clean warm water.
Always mount the cowl cap when the water heater is not being operated! Drain the water heater if there is a risk of frost!
There shall be no claims under guarantee for damage
caused by frost!
Materials in the device which come into contact with water
are suitable for use with drinking water (see manufacturer
declaration: www.truma.com – Manufacturer Declaration).
Filling the Truma Ultrastore with water
Check that the safety/drain valve in the cold water intake is
closed: Lever should be in horizontal position, position (e).
f
e
e
Switching on Gas operation
Ultrastore
50°
b
c
a
a = Red LED “Failure”
b = Water heater “On” 50 °C or 70 °C
c = Water heater “Off”
Never operate the water heater without water in it!
If the cowl is positioned vertically below an opening part of
a window, the water heater must be fitted with an automatic
shut-off device to prevent operation when the window is open.
Remove cowl cover.
Open gas cylinder and open quick-acting valve in the gas supply line.
Switch on water heater at the switch on the control panel (b).
When using the vehicle switches: refer to operating instructions of the vehicle manufacturer or see switch labels.
If there is air in the gas supply line, it may take up to a minute
before the gas is available for combustion. If the appliance
switches to “Failure” during this period, switch off the appliance – wait 5 minutes – and switch on again!
70°
b
e = Lever position “Closed”
f = Lever position “Drain”
Open hot tap in bathroom or kitchen, with pre-selecting mixing taps or single-lever fittings set to “hot”.
Switch on power for water pump (main switch or pump switch).
Leave the tap open to let air escape while the water heater is
filling. The heater is filled when water flows out of the tap.
Residues of frozen water can prevent filling if there is a frost.
The water heater can be defrosted by switching on the heater
for a short period (max. 2 minutes). Frozen pipes can be
defrosted by heating the room.
Draining the water heater
If the mobile home is not used during periods of frost, it
is essential that the Truma Ultrastore be emptied.
Disconnect power for water pump (main switch or pump
switch).
Switching off
Switch off the water heater (c). Mount cowl cap. Drain the
water heater if there is a risk of frost. Close quick-acting valve
in the gas supply line if the appliance is not to be used for a
longer period of time and close the gas cylinder.
Red LED “Failure”
The red LED (a) lights up if there is a failure. For possible causes please refer to page 7. To unlock, switch off the appliance,
wait 5 minutes, and switch on again.
Switching on Electric operation
(230 V ~, 850 W, 3.7 A / 1300 W, 5.7 A)
Ultrastore
g – 850 W
h
g – 1300 W
230 V ~
g = Water heater “On” 850 W or 1300 W
h = Water heater “Off”
Open hot water taps in bathroom and kitchen.
Open safety/drain valve: Lever in vertical position, position (f).
The water heater is now drained directly to the outside via the
safety/drain valve. Check that the water contents have been
completely drained (10 litres).
Never operate the water heater without water in it!
Switch on at the control panel (g).
When using the vehicle switches: refer to operating instructions of the vehicle manufacturer or see switch labels.
The water temperature cannot be selected, automatic
temperature limitation at approx. 70 °C! For a faster
heating up period the appliance can be simultaneously operated with gas and electrical power.
5
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.