Truma Ultrastore Rapid GE, UGE 10 Operating Instructions & Installation Instructions

Ultrastore Rapid GE
Operating instructions Installation instructions Page 9
To be kept in the vehicle!
Page 3
Ultrastore Rapid GE
The Truma Ultrastore Rapid GE has 10 litre capacity. It is more than capable of heating enough water to give out three con­secutive hot showers.
When using the boiler, you should observe the following points to achieve this:
Switch the Ultrastore on 16 minutes before required use.
Switch on dual power mode (gas and electricity),
Gas operation – 70 °C / electric operation – 1300 W Set the mixing tap in the shower to approx. 38 °C and
maintain a medium flow rate (approx 2.5 l / minute) when in the shower Switch off the water when applying shampoo / shower gel etc.
Do not switch the Ultrastore off when showering
As long as the Ultrastore remains in operation, other people can shower as the water is continually reheated.
Example: Sufficient warm water capacity for three consecutive hot showers
Water temperature 38 °C Water flow rate 2.5 l / minute Water consumption per person 12.5 l
2 minutes
Heat up
45 minutes
1 minute
012345678910111213
80
70
60
50
(°C)
40
Temperature
30
20
10
0
1
2
3
4
3 minutes
1 minute
Pause
2 minutes
3 minutes
1 minute
Time t (minutes)
Switch off the water when applying shampoo / shower gel.
2 minutes
Pause
1 minute
14 15 16 17 18 19 20
1 minute
3 minutes
8
7,5
7
6,5
6
5,5
5
4,5
4
3,5
3
2,5
Water flow (filter / minunte)
2
1,5
1
0,5
0
1
2
Warm water (Ultrastore) temperature
Mixed temperature tap
3
4
Water flow
Cold water temperature
2
Table of contents
Symbols used
Symbols used ........................................................................ 3
Safety instructions ............................................................ 4
Important operating notes ............................................... 4
Operating instructions
Filling the Truma Ultrastore with water ................................. 5
Draining the water heater ..................................................... 5
Switching on Gas operation ............................................. 5
Switching off ........................................................................ 5
Red LED “Failure” ................................................................ 5
Switching on Electric operation ...................................... 5
Maintenance ....................................................................... 6
Fuses ..................................................................................... 6
Disposal ................................................................................. 6
Technical data ..................................................................... 6
Trouble-shooting list .......................................................... 7
Declaration of conformity ................................................ 8
Manufacturer’s terms of warranty .................................. 8
Installation instructions
Intended use .......................................................................... 9
Regulations ............................................................................ 9
Water heater kit ................................................................. 9
Choice of location .............................................................. 9
Installation of the water heater ....................................... 9
Water connection ........................................................... 10
John Guest System rigid pipe routing ............................... 10
Flexible water hose routing ................................................. 11
Installation of the safety (pressure relief) drain valve .......... 11
Water pipe routing .............................................................. 11
Gas connection ................................................................. 11
Installation of the control panels .................................. 12
Electrical connection 12 V ............................................. 12
Electrical connection 230 V ........................................... 13
Connection 230 V control panel ......................................... 13
Function check ................................................................. 13
Warning information ....................................................... 13
Accessories ....................................................................... 14
Symbol indicates a possible hazard.
Comment including information and tips.
3
Safety instructions
The use of upright gas cylinders from which gas is taken in the gas phase is mandatory for the operation of gas regula-
tors, gas equipment and gas systems. Gas cylinders from which gas is taken in the liquid phase (e.g. for fork lifts) must not be used, since they would result in damage to the gas system.
In event of leaks in the gas system or if there is a smell of gas:
Items sensitive to heat (e.g. spray cans) must not be stored in the installation area, since excess temperatures may under circumstances be incurred there.
Only pressure control equipment that complies with EN 12864 (in vehicles) with a fixed delivery pressure of 30 mbar must be used for the gas system. The flow rate of the pressure control device must correspond to at least the maximum consump­tion of all devices installed by the system manufacturer.
extinguish all naked flames
do not smoke
switch off all appliances
shut off the gas cylinder
open the windows and doors
do not actuate any electrical switches
have the entire system checked by an expert!
Repairs may only be carried out by an expert.
During use, please observe the regulations of EN 60335-1:2010, according to which this device has not been designed for use by people (including children) who have restricted physical, sensory or mental abilities or a lack of experience and / or knowledge, unless they are supervised by a person respon­sible for their safety or have received instructions from that person as to how the device is to be used.
Children should be supervised to ensure they do not play with the device.
To avoid risk caused by unintentional resetting of the
overtemperature sensor, the device may not be supplied via an external switching device, such as a timer, or be con­nected with a circuit that is regularly switched on and off by any kind of equipment.
Guarantee claims, warranty claims and acceptance of liability will be ruled out in the event of the following:
modifications to the unit (including accessories),
modifications to the exhaust duct and the cowl,
failure to use original Truma parts as replacement parts and
accessories, failure to follow the installation and operating instructions.
It also becomes illegal to use the appliance, and in some countries this even makes it illegal to use the vehicle.
The operating pressure for the gas supply (30 mbar) must cor­respond to the operating pressure of the appliance (see data plate).
Liquid gas systems must accord with the technical and administrative regulations of the particular country in which they are being used (e.g. EN 1949 for vehicles). National regulations must be respected.
Important operating notes
If the cowl has been placed near or directly beneath an open­ing window, the device must be equipped with an automatic shut-off device in order to prevent operation with the window open.
Always mount the cowl cap if the water heater is not being used. Non-observance of this point can lead to the function of the appliance being impaired through water, dirt or insects.
Before setting off on any journey, fit cowl cap with the
boiler switched off. Please ensure that it is secure and has locked into place (risk of accident). Defective cowl caps must not be used.
There shall be no claim under guarantee if this point is not observed. Always remove the cowl cap prior to operating the water heater!
If just the cold water system is being used, without water heater, the heater tank is also filled up with water. In order to avoid damage through frost, the water contents must be drained by actuating the safety/drain valve, also when the heater has not been used. As an alternative, two shut-off valves, resistant to hot water, can be fitted in front of the cold and hot water connection.
Drain the water heater if there is a risk of frost! There shall be no claim under guarantee if this point is not observed.
If connecting to a central water supply (rural or city connec­tion) or when using more powerful pumps, a pressure reducer must be used which prevents pressures of greater than 2.8 bar occurring in the Ultrastore.
The testing of the gas system must be repeated every two years by a qualified specialist and, if appropriate, confirmed on the inspection certificate.
The vehicle owner is always responsible for arranging the inspection.
Liquid gas equipment must not be used when refuelling, in multi-storey car parks, in garages or on ferries.
During the initial operation of a brand new appliance (or after it has not been used for some time), a slight amount of fumes and a slight smell may be noticed for a short while. Remedial action here is to immediately run the heater and to ensure ad­equate room ventilation.
If the burner makes an unusual noise or if the flame lifts off, it is likely that the gas pressure regulator is faulty and it is essential to have it checked.
4
Operating instructions
Always observe the operating instructions prior to starting! The vehicle owner is responsible for the correct
operation of the appliance.
The installer or vehicle owner must apply the yellow sticker with the warning information, which is enclosed with the appliance, to a place in the vehicle where it is clearly visible to all users (e.g. on the wardrobe door)! Ask Truma to send you stickers, if necessary.
Before using the first time, it is essential to flush the
entire water supply through with clean warm water. Always mount the cowl cap when the water heater is not be­ing operated! Drain the water heater if there is a risk of frost!
There shall be no claims under guarantee for damage caused by frost!
Materials in the device which come into contact with water are suitable for use with drinking water (see manufacturer declaration: www.truma.com – Manufacturer Declaration).
Filling the Truma Ultrastore with water
Check that the safety/drain valve in the cold water intake is closed: Lever should be in horizontal position, position (e).
f
e
e
Switching on Gas operation
Ultrastore
50°
b c
a
a = Red LED “Failure” b = Water heater “On” 50 °C or 70 °C c = Water heater “Off”
Never operate the water heater without water in it!
If the cowl is positioned vertically below an opening part of a window, the water heater must be fitted with an automatic shut-off device to prevent operation when the window is open.
Remove cowl cover.
Open gas cylinder and open quick-acting valve in the gas sup­ply line.
Switch on water heater at the switch on the control panel (b).
When using the vehicle switches: refer to operating instruc­tions of the vehicle manufacturer or see switch labels.
If there is air in the gas supply line, it may take up to a minute before the gas is available for combustion. If the appliance switches to “Failure” during this period, switch off the appli­ance – wait 5 minutes – and switch on again!
70°
b
e = Lever position “Closed” f = Lever position “Drain”
Open hot tap in bathroom or kitchen, with pre-selecting mix­ing taps or single-lever fittings set to “hot”.
Switch on power for water pump (main switch or pump switch).
Leave the tap open to let air escape while the water heater is filling. The heater is filled when water flows out of the tap.
Residues of frozen water can prevent filling if there is a frost. The water heater can be defrosted by switching on the heater for a short period (max. 2 minutes). Frozen pipes can be defrosted by heating the room.
Draining the water heater
If the mobile home is not used during periods of frost, it
is essential that the Truma Ultrastore be emptied.
Disconnect power for water pump (main switch or pump switch).
Switching off
Switch off the water heater (c). Mount cowl cap. Drain the water heater if there is a risk of frost. Close quick-acting valve in the gas supply line if the appliance is not to be used for a longer period of time and close the gas cylinder.
Red LED “Failure”
The red LED (a) lights up if there is a failure. For possible caus­es please refer to page 7. To unlock, switch off the appliance, wait 5 minutes, and switch on again.
Switching on Electric operation
(230 V ~, 850 W, 3.7 A / 1300 W, 5.7 A)
Ultrastore
g – 850 W
h
g – 1300 W
230 V ~
g = Water heater “On” 850 W or 1300 W h = Water heater “Off”
Open hot water taps in bathroom and kitchen.
Open safety/drain valve: Lever in vertical position, position (f).
The water heater is now drained directly to the outside via the safety/drain valve. Check that the water contents have been completely drained (10 litres).
Never operate the water heater without water in it!
Switch on at the control panel (g).
When using the vehicle switches: refer to operating instruc­tions of the vehicle manufacturer or see switch labels.
The water temperature cannot be selected, automatic temperature limitation at approx. 70 °C! For a faster
heating up period the appliance can be simultaneously oper­ated with gas and electrical power.
5
Loading...