True TR30REFRSSA, TR30REFLSGA, TR30FRZLSSA, TR30DZWRSGA, TR30REFLSSA Installation Guide

...
TRUE RESIDENTIAL
®
TR-30
INSTALLATION / USER GUIDE
PRESERVE THE MOMENT
®
THANK YOU
FOR YOUR PURCHASE
IN D E X
1-2
SITE PREPARATION, ELECTRICAL REQUIREMENTS
3-6
PLAN VIEWS
7-11
ANTI-TIP BRACKET INSTALLATION, LEVELING THE UNIT
12-15
BASIC ELECTRONIC CONTROL OPERATIONS REFRIGERATOR AND FREEZER
16-22
BASIC ELECTRONIC CONTROL OPERATIONS DUAL ZONE
23-29
SHELVING, REFRIGERATOR STORAGE, FREEZER STORAGE, REMOVING THE DOORS,
KICK PLATE INSTALLATION
30-32
STAINLESS STEEL EQUIPMENT CARE & CLEANING, GENERAL MAINTENANCE, DATA TAG,
WARRANTY STATEMENT, CONTACT US
33-36
NOTE:
AS WE STRIVE FOR CONTINUOUS IMPROVEMENTS, FEATURES AND SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.
30 INCH REFRIGERATOR, FREEZER & DUAL ZONE COLUMN
30” REFRIGERATOR
COLUMN
STAINLESS SOLID DOOR
30” REFRIGERATOR
COLUMN
STAINLESS GLASS DOOR
30” FREEZER
COLUMN
STAINLESS SOLID DOOR
30” DUAL ZONE
WINE COLUMN
STAINLESS GLASS DOOR
Commercial refrigeration refined for the home, envied in the industry,
and crafted—gorgeously—in America.
O w n e r s h i p
1 - 2
s a f e t y p r e c a u t i O n s
D i s p O s a l O f t h e O l D r e f r i g e r a t O r
c f c D i s p O s a l
PRESERVE THE MOMENT
®
30 INCH COLUMNS
1
OWNERSHIP
TO INSURE THAT YOUR UNIT WORKS PROPERLY FROM THE FIRST DAY, IT MUST BE INSTALLED
PROPERLY.
NOTE: WE HIGHLY RECOMMEND A TRAINED REFRIGERATION MECHANIC AND ELECTRICIAN INSTALL YOUR TRUE RESIDENTIAL® CA BIN ET. THE COST OF A PROFESSIONAL INSTALLATION
IS MONEY WELL SPENT.
Before you start to install your True Residential®
Cabinet, carefully inspect it for freight damage. If
damage is discovered, immediately file a claim with
the delivery freight carrier. True is not responsible for
damage incurred during shipment.
Any questions about the installation please
contact your True dealer or True Technical Service
Department at 844-746-9423. Please have your
model and serial numbers available when you call our
Service Department.
NOTE: WE STRONGLY RECOMMEND THAT ANY SERVICING BE PERFORMED BY A QUALIFIED
INDIVIDUAL.
PROPER DISPOSAL OF THE OLD REFRIGERATOR
Child entrapment and suffocation are not problems
of the past. Junked or abandoned refrigerators are
still dangerous...Even if they will sit for “just a few
days”. If you are getting rid of your old refrigerator,
please follow the instructions below to help prevent
accidents.
BEFORE YOU THROW AWAY YOUR OLD REFRIGERATOR OR FREEZER:
• Take off the doors.
• Leave the shelves in place so that children may
not easily climb inside.
SAFETY PRECAUTIONS
• This refrigerator must be properly installed and
located in accordance with the installation
instructions before it is used.
• Do not allow children to climb, stand or hang
on the shelves in the refrigerator. They could
seriously injure themselves or damage the
refrigerator.
• Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
• Keep hands away from the “pinch point” areas
(gaps between the doors and between the doors
and cabinet). Small areas are not necessarily safe.
• Unplug the refrigerator before cleaning and
making repairs.
• Setting temperature control to OFF only removes
power from the refrigeration system, it does not
remove power from other circuits. For example,
temperature control and lights.
CFC DISPOSAL
Your old refrigerator may have a cooling system that
used CFCs (chlorofluorocarbons). CFCs are believed
to harm stratospheric ozone. If you are throwing away
your old refrigerator, make sure the CFC refrigerant
is removed for proper disposal by a qualified service.
If you intentionally release this CFC refrigerant you
can be subject to fines and imprisonment under
provisions of the environment legislation.
TRUE RESIDENTIAL
2
®
3 - 5
s i t e p r e p a r a t i O n
e l e c t r i c a l r e q u i r e m e n t s
PRESERVE THE MOMENT
®
30 INCH COLUMNS
3
SITE PREPARATION
25 25/32"
655mm
FLUSH INSTALL
TR-30REF-R-SG-A
R
TR-30REF-R-SG-A
Rough Opening dimensions. (See figure 1)
For FLUSH installations the front face of the unit will be flush with the surrounding cabinets. (See figure 2)
For PROUD (Standard) installations, the front face of the unit will extend beyond cabinets. (See figure 3)
TR-3 0
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
30 ¼" 25 ⁄" 84 ¼"
* BECAUSE OF THE WEIGHT OF THIS UNIT, IT IS RECOMMENDED TO CONSULT A FLOORING EXPERT PRIOR TO INSTALLATION. THE
FLOORING BENEATH THE UNIT SHOULD BE R ATED TO SUPPORT AT LEAST 150 POUNDS PER SQUARE FOOT.
Width Depth Height
29 ¾" 23 ⁄" 84"
FRONT VIEW
FIGURE 1 - ROUGH OPENING
& ELECTRICAL AREA
Electrical located
in this area.
8"
(204 mm)
2"
(51 mm)
841/4"
(2140 mm)
FLUSH
INSTALL
84"
(2134 mm)
PROUD
INSTALL
77"
(1956 mm)
TOP VIEW
FIGURE 2 - FLUSH INSTALL
TOP VIEW
FIGURE 3 - PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
293/4"
(756 mm)
301/4"
(769 mm)
TRUE RESIDENTIAL
4
PROUD
INSTALL
FLUSH
INSTALL
23 25/32"
604mm
PROUD INSTALL
®
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
TOP VIEW
29 9/16"
135°
20 11/16"
525mm
90°
55 1/4"
1403mm
23 25/32"
604mm
29 15/32"
748mm
31 15/32"
799mm
29 9/16"
751mm
135°
20 11/16"
525mm
TR-30DZW-R-SG-A
135°
20 19/32"
523mm
23 25/32"
604mm
55 1/4"
1403mm
29 15/32"
748mm
31 15/32"
799mm
90°
29 9/16"
751mm
TR-30REF-R-SS-A
25 25/32"
655mm
27 29/32"
709mm
30 15/32"
774mm
2 9/16"
65mm
3 15/16"
100mm
23 25/32"
604mm
90°
29 9/16"
751mm
TR-30REF-R-SS-A
R
FRONT VIEW SIDE VIEW
762mm
30"
2 9/16"
65mm
30 15/32"
774mm
27 29/32"
709mm
25 25/32"
655mm
67 29/32"
1725mm
DOOR
HEIGHT
83 15/16"
72 5/8"
1845mm
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
2132mm
3 15/16"
100mm
30 INCH COLUMNS
5
ELECTRICAL REQUIREMENTS
For all built-in models, the electrical supply should be located within the shaded area shown in
the illustration. Follow the National Electrical Code and local codes and ordinances when installing
the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit
interrupter (GFCI) is not recommended and may cause interruption of operation.
POWER SUPPLY 115 V AC, 60 HZ
CIRCUIT BREAKER 15 AMP
RECEPTACLE 3-PRONG GROUNDING-TYPE
NOTES:
• THE OUTLET MUST BE CHECKED BY A QUALIFIED ELECTRICIAN TO BE SURE THAT IT IS WIRED WITH THE CORRECT POLARITY.
• VERIFY THAT THE OUTLET IS PROPERLY GROUNDED.
FRONT VIEW
ROUGH OPENING &
ELECTRICAL AREA
Electrical located
in this area.
8"
(204 mm)
2"
(51 mm)
841/4"
(2140 mm)
FLUSH
INSTALL
84"
(2134 mm)
PROUD
INSTALL
77"
(1956 mm)
293/4"
(756 mm)
301/4"
(769 mm)
TRUE RESIDENTIAL
6
PROUD
INSTALL
FLUSH
INSTALL
®
p l a n V i e w s
t r - 3 0 / t r - 4 2
7 - 11
t r - 3 0 / t r - 4 8
t r - 3 0 / t r - 3 0
t r - 3 0 / t r - 3 0 / t r - 3 0
PRESERVE THE MOMENT
®
30 INCH COLUMNS
7
TR-30 / TR-42
TR-42,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-42,30DZW
R
TR-42,30DZW
30 15/32"
TR-42,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
72¼" 25 ⁄" 84 ¼"
Width Depth Height
71¾" 23 ⁄" 84"
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
72 1/32"
1829mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
71 3/4" PROUD INSTALL
72 1/4" FLUSH INSTALL
77"
7" TYP
2"
PROUD INSTALL
84 1/4"
84"
FLUSH
INSTALL
774mm
2 9/16"
27 29/32"
65mm
709mm
25 25/32"
655mm
83 15/16"
2132mm
TRUE RESIDENTIAL
8
3 15/16"
®
100mm
TR-30 / TR-48
TR-48,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-48,30DZW
R
TR-48,30DZW
TR-48,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
78¼" 25 ⁄" 84 ¼"
Width Depth Height
77¾" 23 ⁄" 84"
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
78 1/32"
1982mm
ROUGH OPENING & ELECTRICAL AREA
77 3/4" PROUD INSTALL
78 1/4" FLUSH INSTALL
30 1/8"
77"
7" TYP
2"
PROUD INSTALL
84 1/4"
84"
FLUSH
INSTALL
30 15/32"
2 9/16"
65mm
774mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16" 2132mm
3 15/16"
100mm
30 INCH COLUMNS
9
TR-3 0 / T R-30
TR-30REF,30DZW
R
23 25/32"
604mm
PROUD INSTALL
TR-30REF,30DZW
R
TR-30REF,30DZW
30 15/32"
TR-30REF,30DZW
R
FLUSH OPENING DIMENSIONS PROUD OPENING DIMENSIONS
Width Depth Height
60¼" 25 ⁄" 84 ¼"
Width Depth Height
59¾" 23 ⁄" 84"
NOTE: DIMENSIONS MAY VARY BY ± 1/8”
FLUSH VS. PROUD INSTALL
25 25/32"
655mm
FLUSH INSTALL
23 25/32"
604mm
PROUD INSTALL
PLAN VIEW
60 1/32" 1525mm
ROUGH OPENING & ELECTRICAL AREA
30 1/8"
59 3/4" PROUD INSTALL
60 1/4" FLUSH INSTALL
77"
7" TYP
2"
PROUD INSTALL
84 1/4"
84"
FLUSH
INSTALL
774mm
2 9/16"
65mm
27 29/32"
709mm
25 25/32"
655mm
83 15/16"
2132mm
TRUE RESIDENTIAL
10
3 15/16"
®
100mm
Loading...
+ 30 hidden pages