Triton AS2000XT Installation And Operating Instructions Manual

2180404R - Oct 2017
Installation and
operating
instructions
AS2000XT
thermostatic
power shower
critical part of your shower. Failure to use genuine Triton parts
may cause injury and invalidate your guarantee.
Aquasensation AS2000XT
CONTENTS Page
Plumbing and electrical notes ......................................................... 1
Introduction ................................................................................... 2
Safety warnings .............................................................................. 2
Main components .......................................................................... 3
Specifications .................................................................................. 3
Site requirements - water............................................................. 4 − 5
General installation notes ............................................................... 5
Siting of the shower ....................................................................... 6
Removing the cover........................................................................ 7
Plumbing connections ................................................................. 7 − 9
Fitting the shower to the wall ........................................................ 10
Electrical connections .................................................................... 11
Commissioning .......................................................................... 12 − 13
Temperature control spindle setting .............................................. 14
Operating the shower.................................................................... 15
Adjusting the maximum temperature stop .................................... 16
Cleaning the filters ........................................................................ 17
Spare parts .................................................................................... 18
Fault finding .............................................................................. 19 − 20
Water/Cable entry points diagram .................................... 21
Guarantee, service policy, etc. ..................................................rear cover
To check the product suitability for commercial and multiple installations, please contact Triton’s specication advisory service before installation. Please see back of book for contact information.
E mail: technical@tritonshowers.co.uk
WARNING
This appliance can be used by children aged from 3 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervisi
on
or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children may not play with the
appliance. Cleaning and user maintenance shall not be made by
children.
Installers please note these InstructIons are to be left wIth the user
Aquasensation AS2000XT
1
1 PLUMBING NOTES
1.1 All installations must comply with Water
Regulations or Water Bylaws.
1.2 Supply pipes must be flushed to clear
debris before connecting the shower unit.
1.3 DO NOT connect the shower unit to
the mains cold water supply as it would damage the unit and also, the installation would be in breach of Water Regulations.
1.4 DO NOT use excessive force when making
connections to the flexible hose or showerhead – finger tight is sufficient.
1.5 ALL plumbing connections are to be
completed and water supplies turned on BEFORE switching on the electricity supply. The shower must not be operated dry without water.
1.6 DO NOT solder pipes or fittings within
300 mm of the shower appliance, as heat transfer can damage components.
1.7 When installed, the top of the shower unit
must be at least 75 mm lower than the base of the cold water storage cistern to prevent the pump being run dry without water.
1.8 A dedicated cold water supply must be
taken directly from the cold water cistern to the shower. This draw-off must be on the opposite side of the cistern to the float operated valve to reduce the risk of air entering the unit.
1.9 The action of the pump is to increase the
flow rate. If the supply pipework cannot handle the resulting flow rate then:
1.9.1 The anticipated flow rate may not
be achieved.
1.9.2 Air may be drawn into the hot supply from the vent pipe causing spluttering and temperature fluctuations at the showerhead.
1.10 Fullway isolating valves MUST be fitted
on the hot and cold water supplies to the shower as an independent means of isolating the water supplies should maintenance or servicing be necessary. DO NOT use stop taps or ball-o-fix type valves which restrict flow.
2 ELECTRICAL NOTES
2.1 The installation must comply with BS 7671
‘Requirements for electrical installations’ (IEE wiring regulations). Make sure the incoming hot and cold water supplies to the shower are adequately earth bonded.
2.2 DO NOT turn on the electrical supply
until the plumbing connections have been completed. Only then can the electricity be switched on in order to power the solenoid to turn water on to the shower when commissioning. The shower must not be operated dry without water.
2.3 The mains supply must be 230/240V, at
50Hz, connected to the unit via a double pole switched 3 Amp fused connection unit (not supplied) with a minimum 3 mm contact separation gap in each pole.
2.4 In accordance with ‘The Plugs and Sockets
etc. (Safety) Regulations 1994’, this unit is intended to be permanently connected to the fixed electrical wiring of the mains system.
2.5 Fuses do not give personal protection
against electric shock.
2.6 A 30mA residual current device (RCD)
MUST be installed. This may be part of the consumer unit or a separate unit.
Aquasensation AS2000XT
2
INTRODUCTION
This book contains all the necessary fitting and operating instructions for your Triton Power Shower. Please read them carefully.
The shower installation must be carried out by suitably competent person and in sequence of this instruction book.
Care taken during the installation will ensure a long and trouble free life from your shower
IMPORTANT: All plumbing connections must be completed BEFORE making the electrical connections.
Please read through the whole of this book before beginning your installation.
IMPORTANT: The fittings on the pipe inlet elbows are of the push-in type. The pipework must be cut with a pipe cutter and all burrs and rough edges removed from the end of the tube. The fittings can be used with copper and plastic pipe. Where chrome plated pipe is used, remove the first 25 mm of plating.
Note: The pump inside this product is rated 15 minutes on / 45 minutes off duty cycle.
SAFETY WARNINGS
a. DO NOT insert fingers into the push-in inlet
fittings. Doing so could cause injury.
b. Under no circumstances must this product
be connected to mains cold or hot water supplies. Failure to comply will invalidate
the guarantee.
c. The shower MUST NOT be used if
suspected of being frozen.
d. The outlet of this appliance MUST NOT be
connected to any form of tap or fitting not recommended by the manufacturer.
e. The showerhead cartridge MUST be cleaned
regularly to remove scale and debris.
f. This appliance MUST be earthed.
g. Switch off immediately at the isolating
switch if water ceases to flow during use.
h. DO NOT operate the shower outside the
guidelines laid out in ‘site requirements’.
i. DO NOT operate the shower if the
showerhead or spray hose becomes damaged.
j. DO NOT restrict flow out of the shower by
placing the showerhead in direct contact with your body.
Replacement parts can be ordered from Triton Customer Service. See ‘spare parts’ for details and part numbers.
A 30mA residual current device (RCD) MUST be installed in all UK 230V electric and pumped shower circuits. This may be part of the consumer unit or a separate unit.
Aquasensation AS2000XT
3
Hot water temperature
Maximum temperature 65°C. BS 6700 recommends that the temperature of stored water should never exceed 65°C. A stored water temperature of 60°C is considered sufficient to meet all normal requirements and will minimise the effects of scale in hard water areas.
Temperature control
To obtain the maximum performance, this unit should be installed, operated and maintained as instructed in this book. The full performance specification as below for the unit is achieved with a blend set between 35°C – 40°C and supplies of 15°C cold and 65°C hot with nominally equal pressures.
1. The blended water temperature is maintained
within 2°C with a 10°C change in the hot and cold water supply.
2. The sensor effects a shut down to seepage in
about 2 seconds if the cold supply fails.
3. Shut down to seepage is achieved even if
the hot supply is only 12°C above the blend temperature.
4. The blended water temperature is maintained
within 1°C when the pressure between inlet and outlet is halved (defined as a pressure loss ratio of 2:1) on either the hot or cold side.
Maximum static inlet pressures
100 Kpa (1 bar) or 10m (supplies must be gravity fed at nominally equal pressures).
Minimum static inlet pressure
0.75 Kpa (0.0075 bar) or 75mm (required to prime the integral centrifugal pump).
Maximum supply head 10m.
SPECIFICATIONS
MAIN COMPONENTS
1. Top pipe entry and cable entry
2. Terminal block
3. Cover screw fixing
4. Motor retaining bracket
5. Rear pipe entry and cable entry
6. Wall fixing holes
7. Pipe inlet elbow – top
(contains single check valves)
8. Filter cover – top
9. Pump
10. PCB housing
11. Setting adaptor
12. Temperature control valve
13. Solenoid
14. Filter cover - bottom
15. Pipe inlet elbow – bottom (contains single check valves)
16. Outlet
17. Bottom pipe entry
1
2
3
5
6
6
6
6
7
8
9
3
3
10
11
12
13
15
16
17
14
4
56 mm
268 mm
86
mm
82 mm
206 mm
Fig.1
Aquasensation AS2000XT
4
Fig.3 illustrates all the incorrect connections that
must be avoided.
All pipework to the shower unit must be routed where it remains below the level of water in the cistern. In the case of horizontal sections of pipework in lofts, it may be necessary to fit automatic air vents at high points on the supplies to remove the possibility of air locks.
For the operation of the shower only, it is recommended that the cold water storage cistern is capable of holding at least 114 litres (25 gallons). Where other hot and cold outlets are likely to be in use simultaneously, the storage capacity should be increased to 228 litres (50 gallons) in accordance with BS 6700.
Do ensure compliance with the Water Regulations/Bylaws.
DO NOT connect to a combination cylinder unless there is a guaranteed 114 litre cold supply to the cylinder as the shower can deliver up to 14 litres per minute. It is advisable to check that
Mains supply
Isolating
valve
Cold water cistern
Vent pipe tee
Isolating
valve
Hot supply
Hot water
cylinder
Drain
valve
Other hot water
draw-offs
Alternative connection
Shower unit
Ring main
25mm min
Isolating spur
(3A fused)
outside bathroom
Dedicated cold supply
10m max
75mm
min
Isolating
valves
SITE REQUIREMENTS
Water
The installation must be in accordance with Water Regulations/Bylaws and BS 6700.
For correct operation of this shower unit, both hot and cold water supplies to the appliance must be gravity fed, at nominally equal pressures, from a cold water storage cistern and a hot water storage cylinder.
The water circuit should be installed so that the flow is not significantly affected by other taps and appliances being operated elsewhere on the premises.
Fig.2 shows a recommended installation where the hot water supply for the shower is made via a tee connection on the underside of the horizontal section of pipework from the cylinder. Alternatively, the connection can be taken from the hot supply pipe to other outlets as long as it is the first draw-off below the ventilation pipe tee.
Fig.2 (Diagrammatic view – not to scale)
Aquasensation AS2000XT
5
the infill rate from the float operated valve meets the output requirements..
It is recommended that there is a minimum of approximately 114 litres (25 gallons) of hot water storage per appliance.
The shower MUST NOT be connected to the mains cold water supply.
DO NOT use jointing compounds.
GENERAL INSTALLATION NOTES
1. DO NOT take risks with plumbing or
electrical equipment.
2. DO NOT install this unit in a position where
it could become frozen.
3. Isolate electrical and water supplies BEFORE
proceeding with installation work.
4. Shower control MUST be fed from a cold
water storage cistern and hot water cylinder that provides nominally equal pressures.
Fig.3 (Diagrammatic view
not to scale)
5. The unit must be mounted onto the finished
wall surface (on top of tiles).
DO NOT tile up to the unit after fixing to
the wall.
6. If installing with rear inlet supplies, it is
recommended the supply pipework is sealed to the wall so as to prevent water from leaking back into the wall.
7. In solid wall installations, the supply
pipework should be housed within ducting in order to allow some free lateral movement when making connections and to ensure compliance with requirements of accessibility of pipes and pipe fittings.
Fig.4 shows a schematic wiring diagram of the unit.
Aquasensation AS2000XT
6
Shower can be mounted
either side of
the riser rail
Spill-over
level
Ceiling
Use soap dish
retaining ring
Height of
sprayhead
and shower
to suit user’s
requirement
Shower unit must not be
within an area
1 metre
from base
Space for cover
screw access
Fig.5
SITING OF THE SHOWER
IMPORTANT: If fitting to a tiled wall, always mount the unit on the surface of the tiles. NEVER tile up to the unit.
Refer to fig.5 for correct siting of the shower. Position the unit vertically where it will NOT be in direct contact with water from the showerhead.
Note: Allow sufficient room between the ceiling and the shower unit to access the top cover screw.
Position the shower and showerhead on the wall so that all controls can be comfortably reached when using the shower.
The showerhead and riser rail can be positioned either side of the shower unit.
Note: Water Regulations require the showerhead be ‘constrained by a fixed or sliding attachment so that it can only discharge water at a point not less than 25mm above the spill-over level of the relevant bath, shower tray or other fixed appliance’. The use of the supplied soap dish will in most cases meet this requirement, but if the showerhead can be placed within a bath, basin or shower tray, then a device must be fitted to prevent back-flow.
L E N
Potentiometer
Switch
Solenoid
Motor
Capacitor 2
RFI suppression coil
Capacitor 1
PCB
Thermal fuse
Fig.4 (schematic view )
WARNING!
The shower must not be positioned
where it will be subject to freezing
conditions.