Triton 8100 Operation Manual

Model 8100
QUICK REFERENCE CARD
01/2006
THIS AREA FOR SER VICE PROVIDER
CONT ACT INFORMATION:
TDN 07100-00054
MANAGEMENT FUNCTIONS
ACCESS INSTRUCTIONS
2. AT THE TOP MENU, SELECT MANAGEMENT FUNCTIONS OPTION. ENTER P ASS­WORD TO ACCESS MANAGEMENT FUNCTIONS MENU. THE MAIN MENU SCREEN (RIGHT) WILL BE DISPLAYED (ADMINISTRATIVE P ASSWORD ACCESS).
RESETTING ERRORS
RESET A TM RESET ERROR
RESET ATM: OPEN THE A TM CONTROL P ANEL AND LOCA TE THE ON/OFF SWITCH ON THE UNITS POWER SUPPL Y T OW ARDS THE REAR OF THE ENCLOSURE. PRESS THE POWER SWITCH OFF (0) THEN ON (I).
RESET ERROR: AFTER AN ATM RESET, THE RESET ERROR AND MANAGEMENT FUNC­TION OPTIONS APPEAR. SELECT THE RESET ERROR OPTION. IF THE PROBLEM HAS BEEN CORRECTED, THE A TM SHOULD RETURN T O NORMAL OPERA TION.
DIAGNOSTICS
PURGE TEST DISPENSE TEST RECEIPT PRINTER
ACCESS MANAGEMENT FUNCTIONS USING ACCESS INSTRUCTIONS AND SELECT THE DIAGNOSTICS FUNCTION:
PURGE: INSTRUCTS DISPENSER TO REMOVE ANY NOTES IN FEED P ATH. THE CODE DISPLA YED FOR A SUCCESSFUL PURGE IS ‘20 20 20’.
TEST DISPENSE: INSTRUCTS DISPENSER TO DISPENSE ONE (1) NOTE FROM THE CASSETTE INTO THE REJECT COMP ARTMENT . THE CODE DISPLA YED FOR A SUC­CESSFUL TEST DISPENSE IS ‘20 1 0 0 0’.
TEST RECEIPT PRINTER: TESTS THE OPERATION OF THE RECEIPT PRINTER AND PRINTS A TERMINAL CONFIGURATION SUMMARY .
2
Loading...
+ 4 hidden pages