Tri-Star Manufacturing TSHEF-15Si Service Manual

FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the Installation, Operating and Maintenance Instructions thoroughly before installing or servicing this equipment
WARNING
Initial heating of oven may generate smoke or fumes and must be done in a well-ventilated area. Overexposure to smoke or fumes may cause nausea or dizziness.
Tri-Star Manufacturing Company
1307 N. Watters Rd. #180
Allen, TX 75013
(800) 462-1340 Toll Free
www.Tri-StarMfg.com
(214) 421-7366 Phone (914) 576-0605 Fax
INSTALLATION AND OPERATING INSTRUCTIONS
HEAVY DUTY ELECTRIC FRYERS
Models: TSHEF-15Si, TSHEF-30Ti
INTENDED FOR OTHER THAN HOUSEHOLD USE
RETAIN THIS MANUAL FOR FUTURE REFERENCE
This equipment has been engineered to provide you with year-round dependable service when used according to the instructions in this manual and standard commercial kitchen practices.
1
P/N 8822395 8/13
TABLE OF CONTENTS
DANGER: This symbol warns of imminent hazard which will result in serious injury or
death.
WARNING: This symbol refers to a potential hazard or unsafe practice, which could result in serious injury or death.
CAUTION: This symbol refers to a potential hazard or unsafe practice, which may result in minor or moderate injury or product or property damage.
NOTICE: This symbol refers to information that needs special attention or must be fully understood even though not dangerous.
CAUTION: These models are designed, built, and sold for commercial use. If these models are positioned so the general public can use the equipment make sure that cautions, warnings, and operating instructions are clearly posted near each unit so that anyone using the equipment will use it correctly and not injure themselves or harm the equipment.
WARNING: Check the data plate on this unit before installation. Connect the unit only to the voltage and frequency listed on the data plate. Connect only to 1 or 3 phase as listed on the data plate.
SECTION ITEM PAGE SECTION ITEM PAGE
1 Safety Precautions ..................... 2 8 Cleaning ......................................... 7
2 General Information .................... 4 9 Specifications .................................. 8
3 Description ................................. 5 10 Wiring Diagrams ............................. 9
4 Installation .................................. 5 11 Troubleshooting Guide .................. 11
5 Thermostat Calibration ............... 6 12 Suggested Temperature & Times . 12
6 Operating ................................... 6 13 Replacement Parts ....................... 12
7 Maintenance ............................... 7 14 Warranty ....................................... 18
Tri-Star Manufacturing takes pride in the design and quality of our products. When used as intended and with proper care and maintenance, you will experience years of reliable operation from this equipment. To ensure best results, it is important that you read and follow the instructions in this manual carefully.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instructions.
If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department: Tri-Star Manufacturing, 1307 N Watters Rd. #180, Allen, TX 75013.
1. SAFETY PRECAUTIONS
Before installing and operating this equipment be sure everyone involved in its operation are fully trained and are aware of all precautions. Accidents and problems can result by a failure to follow fundamental rules and precautions.
The following words and symbols, found in this manual, alert you to hazards to the operator, service personnel or the equipment. The words are defined as follows:
2
WARNING: Electrical and grounding connections must comply with the applicable portions of the national electrical code and/or other local electrical codes.
WARNING: Disconnect device from electrical power supply and place a Tag Out-Lockout on the power plug, indicating that you are working on the circuit.
WARNING: Install per the spacing requirements listed in the installation section of this manual. We strongly recommend having a competent professional install the equipment. A licensed electrician should make the electrical connections and connect power to the unit. Local codes should always be used when connecting these units to electrical power. In the absence of local codes, use the latest version of the National Electrical Code.
WARNING: This device should be safely and adequately grounded in accordance with local codes, or in the absence of local codes, with the National Electrical code, ANSI/NFPA 70, Latest Edition to protect the user from electrical shock. It requires a grounded system and a dedicated circuit, protected by a fuse or circuit breaker of proper size and rating. Canadian installation must comply with the Canadian Electrical Code, CSAC22.2, as applicable.
CAUTION: Do not set the fryer with its back flat against the wall. It will not operate properly unless there is at least 3" breathing space behind fryer.
WARNING: A factory authorized agent should handle all maintenance and repair. Before doing any maintenance or repair, contact Tri-Star Manufacturing.
WARNING: Never clean any electrical unit by immersing it in water. Turn off before cleaning surface.
WARNING: An earthing cable must connect the appliance to all other units in the complete installation and from there to an independent earth connection.
NOTICE: The unit when installed must be electrically grounded and comply with local codes, or in the absence of local codes, with the national electrical code ANSI/NFPA70­latest edition. Canadian installation must comply with CSA-STANDARD C.22.2 Number 0 M1982 General Requirements-Canadian Electrical Code Part II, 109-M1981- Commercial Cooking Appliances.
WARNING: SHOCK HAZARD - De-energize all power to equipment before cleaning the equipment.
NOTICE: This product is intended for commercial use only. Not for household use.
NOTICE: Local codes regarding installation vary greatly from one area to another.
The National Fire Protection Association, Inc. states in its NFPA96 latest edition that local codes are “Authority Having Jurisdiction” when it comes to requirement for installation of equipment. Therefore, installation should comply with all local codes.
3
CAUTION: This product when stacked has more than one power supply connection point. Disconnect all power supplies before servicing.
CAUTION: Suitable for installation on combustible floor when installed with legs or casters provided.
WARNING: SHOCK HAZARD - Do not open any panels that require the use of tools.
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or Parts, this information is required.
Model Number
Serial Number
Date Purchased
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier.
A) Apparent damage or loss: must be noted on the freight bill at the time of delivery. It must then be
signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can supply the necessary forms.
B) Concealed damage or loss: if not apparent until after equipment is uncrated, a request for inspection
must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all contents and packaging material.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instructions.
2. GENERAL INFORMATION
General Installation:
1. Always clean equipment thoroughly before first use (see “General Cleaning Instructions”).
2. Check rating label for your model designation & electrical rating.
3. For best results, use stainless steel countertops.
4. Attach legs to unit.
General Operation Instructions:
1. All food service equipment should be operated by trained personnel.
2. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”.
3. Where applicable, never pour cold water into dry heated units.
4. NEVER hold food below 140°F.
General Cleaning Instructions:
1. Refer to section 8, page 7.
4
General Troubleshooting:
CAUTION: Installing personnel should be guided by National Electrical Code NFPA
Number 70- (Latest Edition), and applicable local codes.
Always ask and check:
1. Is the unit connected to a live power source?
2. Check circuit breaker.
3. Is power switch “ON” and pilot light glowing?
4. Check rating label. Are you operating unit on proper voltage? If the above checks out and you still have problems, call an Tri-Star authorized service agency.
3. DESCRIPTION
Electric Fryers:
These electric units are designed for countertop operation. They are used for producing evenly cooked, perfectly fried products.
4. INSTALLATION
1. Follow General Installation Instructions on previous page.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the
fryer by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary to move unit.
For testing, see the wiring diagrams in this manual for the rated amperages.
NOTE: These values are nominal ratings. Field wire connections must be capable of withstanding anticipated surges.
5
5. THERMOSTAT CALIBRATION
Checking Thermostat Calibration:
The fryer thermostat is carefully calibrated at the factory so that dial settings match actual frying compound temperatures. Field re-calibration is seldom necessary unless the unit has been mishandled in transit or abused. Re-calibration should not be resorted to unless considerable experience with cooking results definitely proves that the control is not maintaining the temperature to which the dial is set.
1. To check compound frying temperatures when re­calibrating, use a precision test instrument, or a good grade mercury thermometer. Fill the tank half way between the MAX and MIN marks on the tank.
2. Frying compound temperature should be checked at the center of the tank, approximately 1” to 1 1/2” below surface of frying compound.
3. Turn the dial of the thermostat being checked to the 350°Fmark.
4. Allow temperature to stabilize, or until the thermostat
cycles to “OFF” three times after starting with cold
frying compound. With power “ON”, read highest and
lowest frying compound temperature, as thermostat cycles through at least two cycles. Average the reading.
5. Thermostat should be re-calibrated if temperature reading is not within 15 degrees of the control knob setting (350°F +/- 15°F). If re-calibration is required, continue with steps 6, 7, 8 and 9.
6. Remove control knob by grasping outer edge and pulling straight out, without twisting or turning.
7. Hold thermostat dial shaft “B” (Figure 1) stationary with pliers, and with a screwdriver, turn screw “A” clockwise to obtain a lower temperature; or counter-clockwise for higher temperature. Each ¼ turn (90° rotation) of screw “A” represents 18°F.
8. Replace thermostat control knob.
9. Recheck thermostat as in Steps 4 and 5 above. If the fat temperature is not within 20 degrees of dial setting (350°F +/- 20°F), it means that the sensing element is inoperative and the thermostatic control should be replaced.
6. OPERATING
Removing Fry Tanks (Fry tanks equipped with drain are not to be removed):
1. Remove fry baskets.
2. Carefully grasp the element handle. CAUTION: May be hot. Pull out the head lock on the left of the head.
3. Lift the element handle while at the same time, pulling the head lock. This will permit lifting the elements to just above frying compound level in tank. The element can be left in this position for draining frying compound.
4. Again, lift the element handle while pulling the head lock, until the elements lock themselves at a higher position.
5. Firmly grasp both handles of fry tank and lift it out. After replacing the fry tank, simply pull the head lock; and at the same time, pull down the element handle until the elements rest on fry tank bottom.
6. Both the lifting out and lowering of elements can be done in one swing, without stopping at the intermediate position.