SmartPro Medical-Grade UPS, Line Interactive,
Lithium Battery, 6 Outlets - 230V, 700VA, 450W,
Full Isolation
MODEL NUMBER: SMX700HGL
Line-interactive UPS provides basic battery backup with UL 60601-1 compliance for use in medical
facilities, including patient care areas.
Highlights
●
Lithium battery backup allows
time to save files and safely shut
down during blackouts
●
6 C13 hospital-grade (HG)
outlets provide power to medical
equipment
●
Approved for use within the
Patient Care Vicinity
●
Approved to EN60601-1-2:2015,
4th Edition
●
Alarm and front-panel LEDs
report online, battery, fault and
overload conditions
●
10,000-cycle LiFePO4 battery
lasts up to 30x longer than
comparable SLA batteries
Features
700VA/450W Medical-Grade UPS Allows Time to Back Up Critical Files During a BlackoutThis 230V
SmartPro® hospital-grade UPS is fully compliant with UL 60601-1 regulations when plugged into a
hospital-grade outlet, which makes it ideal for use in medical facilities, including patient care vicinities. It
allows you to work through short power failures, and gives you enough time to safely save files and shut
down your system in case of a prolonged blackout.
Long-Lasting LiFePhos Battery Handles up to 10,000 Cycles with EaseThis UPS system for hospitals
contains a replaceable lithium iron phosphate (LiFePhos) internal battery that provides up to 30 times the
cycle life of traditional sealed lead acid (SLA) batteries. The 6-outlet UPS system provides up to 42
minutes of battery backup at half load and 18 minutes at full load. During normal operation, incoming utility
power keeps the replaceable internal battery fully charged, so backup power will always be available.
Automatic Voltage Regulation (AVR) Corrects Potentially Hazardous Voltage FluctuationsAVR
protects your equipment from incremental hardware damage, data loss and performance problems
caused by brownouts. This UPS for medical equipment can correct brownouts as low as 155V and
overvoltages as high as 274V back to nominal 230V power without drawing on the battery backup needed
to support your equipment during a blackout.
Built-In Isolation Transformer Offers Full IsolationThe isolation transformer with Faraday shield offers
full isolation and removes common mode noise while maintaining full AC surge suppression in all modes.
Cumulative leakage current of all connected equipment is less than 100 microamps.
Connect Your Equipment to 6 IEC 320 C13 OutletsSix C13 hospital-grade outlets provide both battery
backup and surge protector for your mobile medical equipment, such as computers, monitors and lab
equipment. A 340-joule surge suppression rating protects connected components from the harmful effects
of power surges.
Combats Electromagnetic Interference That Can Harm EquipmentVarious electromagnetic and radio
sources found in virtually every home and business can cause disruptive interference on the AC line.
Known as EMI (electromagnetic interference) and RFI (radio frequency interference), this line noise is a
common cause of performance problems and can lead to incremental hardware damage, data corruption
and audio/video transmission problems. This medical-grade UPS system incorporates technology that
filters out disruptive line noise so that it won’t affect your equipment.
Easy-to-Read LEDs and Alarm Report Real-Time UPS and Power StatusFront-panel LED indicators
monitor essential information, such as line power, battery power, overload, voltage regulation and battery
low/replace status. An audible alarm will sound in case of low battery, excessive load and power failure.
Saves Your Files, Even When You’re AwayUSB and DB9 serial ports connect to your computer with the
included cables. These ports communicate with Tripp Lite’s free downloadable PowerAlert® software for
Applications
●
Protect your medical electronics
against power surges,
brownouts and blackouts in
patient care vicinities
●
Operate essential equipment
during short-term power outages
using battery backup power
●
Shut down PCs, monitors,
mobile medical components and
other equipment without data
loss during long-term power
outages
safe, unattended system shutdown and file saves in the event of a prolonged power failure.
Tower Form Factor for Easy Placement on a Nurse’s Station or Mobile Medical CartThe long-lasting
PVC housing fits easily on a desktop, shelf or anywhere else power is needed. The 15-centimeter (sixinch) dongle with hospital-grade C14 plug connects to a properly grounded AC wall outlet.
Recommended Electrical Service10A 230V
Voltage Compatibility (VAC)230
Input PhaseSingle-Phase
OUTPUT
Output Volt Amp Capacity (VA)700
Output Watt Capacity (Watts)450
Nominal Voltage Details230v nominal inverter output voltage
Frequency Compatibility50 / 60 Hz
Frequency Compatibility DetailsAutomatic frequency selection
Output Voltage Regulation (Line
Half Load Runtime (min.)36 min. (225w)
DC System Voltage (VDC)36
Battery Recharge Rate (Included
Batteries)
Internal UPS Replacement Battery
Cartridge
Less than 3.6 hours from 10% to 90% (typical, full load discharge)
RBC53L
Battery AccessBattery access door allows hot swap battery replacement without powering connected equipment off
Typical Battery Lifespan3-6 years, depending on usage
Expandable RuntimeNo
VOLTAGE REGULATION
Voltage Regulation DescriptionLine interactive UPS offers 2 boost levels of brownout correction and a single level of overvoltage adjustment to
maintain usable, computer grade output without consuming battery power over an input voltage range of 155 to
274V AC
Overvoltage CorrectionInput voltages between 206 and 245V AC are reduced by 9%
Undervoltage CorrectionInput voltages between 183 and 199 are boosted by 10%
Severe Undervoltage CorrectionInput voltages between 155 and 182 are boosted by 21%
USER INTERFACE, ALERTS & CONTROLS
SwitchesYes, includes 2 front panel mounted push-button switches for system enable, self-test and alarm cancel functions
Audible Alarm3 function audible alarm indicates power failure conditions (4 short beeps every 10 seconds), overload (continuous
short beeps) and low battery (continuous tone). Audible Alarm is factory muted for silent operation; Audible alarm
can be restored to indicate power failure, overload conditions and Low Battery events, using our Free PowerAlert
UPS management software.
LED Indicators5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating340
EMI / RFI AC Noise SuppressionYes
AC Suppression Response TimeInstantaneous
PHYSICAL
Cooling MethodCooling via rear-exit cooling fan
Installation Form Factors Supported
with Included Accessories
Installation Form Factors Supported