Tripp Lite PDU Series, PDUV30HV, PDUMV30HV, PDUMV30, PDUMV16HV Owner's Manual

...
Owner’s Manual
Metered Rack PDU
Models: PDUV30HV, PDUMV30, PDUMV16HV,
PDUMV20HV, PDUMV30HV
(Series Number: AGIB6672, AGPD6673, AGPD6674, AGPD6675)
Español 6 • Français 11 • Русский 16 • Deutsch 21
PROTECT YOUR INVESTMENT!
Register your product for quicker service
and ultimate peace of mind.
You could also win an
ISOBAR6ULTRA surge protector—
a $100 value!
www.tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
1
18-11-318-933312.indb 1 3/20/2019 1:22:51 PM
Important Safety Instructions
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be followed during the installation, operation and storage of this product. Failure to heed these instructions and warnings will void the product warranty.
Important Warnings
• The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line noise protection for connected equipment.
• The PDU is designed for indoor use only, in a controlled environment, away from excess moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• The PDU must be installed by a qualified technician only.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Install in accordance with National Electrical Codes. Be sure to use the proper over current protection for the installation, in accordance with the plug rating/equipment rating as follows:
Model Series Number Overcurrent Protection
PDUV30HV AGIB6672 30A PDUMV30 AGPD6673 30A PDUMV16HV, PDUMV20HV AGPD6674 20A PDUMV30HV AGPD6675 30A
• Short-circuit backup protection and overcurrent protection is provided by the building installation.
• The electrical outlets supplying power to the equipment should be installed near the equipment and easily accessible.
• Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that eliminate the connection to ground.
• The plug on the power supply cord is intended to serve as the disconnect device. Be sure that the socket-outlet is installed near the equipment and is made easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• The power requirement for each piece of equipment connected to the PDU must not exceed the individual outlet’s load rating.
• The total power requirement for equipment connected to the PDU must not exceed the maximum load rating for the PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
• Do not drill into or attempt to open any part of the PDU housing. There are no user­serviceable parts inside.
• Do not attempt to use the PDU if any part of it becomes damaged.
2
18-11-318-933312.indb 2 3/20/2019 1:22:51 PM
Important Safety Instructions
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended.
Installation
Note: The user must determine the fitness of hardware and procedures before mounting. The PDU and included hardware are designed for common rack and rack enclosure types and may not be appropriate for all applications.
1A
0U Rack Configuration (Mounting Brackets). Prior to installation,
determine the rack location in which the PDU is to be installed. Attach the mounting brackets to the back of the PDU as shown, using the included screws. To assist with proper positioning, the brackets have four screw holes each; make sure that the same two holes are used to attach each bracket to the PDU. After attaching the brackets, position the PDU in the rack and mount it by installing four user-supplied screws through the brackets into the rack.
1A
1B
0U Rack Configuration (Mounting Buttons). Attach the included mounting
buttons to the PDU. Position the PDU as desired in the rack enclosure, align the buttons with the rack mounting slots, and slide the PDU into position.
1C
Under-Counter Configuration. The PDU
1B
may be installed under a counter using the included mounting brackets. Attach the mounting brackets to the back of the PDU as shown in STEP 1A. Secure the PDU to the underside of the counter by installing two user-supplied screws through each bracket into the counter.
1C
3
18-11-318-933312.indb 3 3/20/2019 1:22:51 PM
Features
IEC-60320-C13
IEC-60320-C19
Outlets: During normal operation, the outlets distribute AC power to connected equipment.
Input Plug: The cord is permanently attached to the PDU and has an IEC 309 16A plug.
Ammeter: The total electrical current used by the PDU will be displayed on the digital meter in amperes.
PDUMVROTATEBRKT Mounting Accessory: Use these V-shaped brackets to mount the PDU with its outlets facing the rear of the rack.
Mounting Brackets: Use these brackets as an alternate PDU mounting method.
Mounting Buttons: Come pre-installed on the back side of the PDU and are used for toolless mounting. Note: Four additional
mounting buttons are included for alternate rack styles.
C14 Plug Sleeve: (Optional) Use the included C14 plastic sleeves to secure plugs to receptacles. Attach the sleeve to the plug making sure that the pull tabs remain outside the plug and that the fit is secure. To unplug equipment properly, use the pull tabs to remove the plug and sleeve from the receptacle.
C20 Plug Sleeve: (Optional) Use the included C20 plastic sleeves to secure plugs to receptacles. Attach the sleeve to the plug making sure that the pull tabs remain outside the plug and that the fit is secure. To unplug equipment properly, use the pull tabs to remove the plug and sleeve from the receptacle.
4
18-11-318-933312.indb 4 3/20/2019 1:22:53 PM
Warranty and Product Registration
2-YEAR LIMITED WARRANTY
Seller warrants this product, if used in accordance with all applicable instructions, to be free from original defects in material and workmanship for a period of 2 years from the date of initial purchase. If the product should prove defective in material or workmanship within that period, Seller will repair or replace the product, in its sole discretion. Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago, IL 60609 USA. Seller will pay return shipping charges. Visit www.tripplite.com/support before sending any equipment back for repair.
THIS WARRANTY DOES NOT APPLY TO NORMAL WEAR OR TO DAMAGE RESULTING FROM ACCIDENT, MISUSE, ABUSE OR NEGLECT. SELLER MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY EXPRESSLY SET FORTH HEREIN. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF MERCHANTABILITY OR FITNESS, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET FORTH ABOVE; AND THIS WARRANTY EXPRESSLY EXCLUDES ALL INCIDENTAL AND CONSEQUENTIAL DAMAGES. (Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This Warranty gives you specific legal rights, and you may have other rights which vary from jurisdiction to jurisdiction).
WARNING: The individual user should take care to determine prior to use whether this device is suitable, adequate or safe for the use intended. Since individual applications are subject to great variation, the manufacturer makes no representation or warranty as to the suitability or fitness of these devices for any specific application.
PRODUCT REGISTRATION
Visit www.tripplite.com/warranty today to register your new Tripp Lite product. You’ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product!
** No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
Regulatory Compliance Identification Numbers
For the purpose of regulatory compliance certifications and identification, your Tripp Lite product has been assigned a unique series number. The series number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to the series number. The series number should not be confused with the marking name or model number of the product.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when customers buy new electrical and electronic equipment from Tripp Lite they are entitled to:
• Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country)
• Send the new equipment back for recycling when this ultimately becomes waste
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
5
18-11-318-933312.indb 5 3/20/2019 1:22:54 PM
18-11-318 93-3312_revC
Manual del Propietario
PDU para montaje en rack
(bastidor) con amperímetro
Modelos: PDUV30HV, PDUMV30, PDUMV16HV,
PDUMV20HV, PDUMV30HV
(Número de Serie: AGIB6672, AGPD6673, AGPD6674, AGPD6675)
English 1 • Français 11 • Русский 16 • Deutsch 21
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2019 Tripp Lite. Todos los derechos reservados.
6
18-11-318-933312.indb 6 3/20/2019 1:22:54 PM
Instrucciones de seguridad importantes
GUARDE ESTAS INSTRUCCIONES
Este manual contiene instrucciones y advertencias que deben seguirse durante la instalación, operación y almacenamiento de este producto. De no seguirlas, se anulará la garantía del producto.
Advertencias Importantes
• El PDU proporciona la conveniencia de múltiples tomacorrientes, pero NO proporciona protección contra sobretensión o ruido en la línea para los equipos conectados.
• El PDU está diseñada solo para uso en interiores en un entorno controlado lejos de humedad excesiva, temperaturas extremas, contaminantes conductivos, polvo o luz del sol directa.
• El PDU debe ser instalado solamente por un técnico calificado.
• No intente instalar el PDU en una superficie inestable o no segura.
• Instale de acuerdo con los reglamentos eléctricos locales. Asegúrese de usar para la instalación la protección adecuada contra sobrecorriente, de acuerdo con la especificación de la clavija o del equipo como sigue:
Protección Contra
Modelo Número de Serie
PDUV30HV AGIB6672 30A PDUMV30 AGPD6673 30A PDUMV16HV, PDUMV20HV AGPD6674 20A PDUMV30HV AGPD6675 30A
Sobrecorriente
• Conecte el PDU a un tomacorriente que esté de acuerdo a los códigos locales de construcción y que esté correctamente protegido contra corrientes excesivas, cortocircuitos y fallas de conexión a tierra.
• Los tomacorrientes eléctricos que suministran energía al equipo deben instalarse próximos al equipo y ser fácilmente accesibles.
• No conecte El PDU a un toma corriente que no esté a tierra o cables de extensión o adaptadores que eliminen la conexión a tierra.
• Asegúrese de proporcionar un dispositivo local de desconexión, que sea fácilmente accesible, en cualquier modelo que esté instalado permanentemente sin una clavija.
• Nunca intente instalar equipos eléctricos durante una tormenta eléctrica.
• El equipo individual conectado al PDU no debe consumir más corriente que la de la especificación de cada tomacorriente individual del PDU.
La carga total conectada al PDU no debe exceder la capacidad de carga máxima del PDU.
• No intente modificar el PDU, las clavijas de entrada o los cables de alimentación.
• No perfore ni intente abrir ninguna parte del gabinete del PDU. No tiene partes a las que el usuario pueda dar servicio.
7
18-11-318-933312.indb 7 3/20/2019 1:22:54 PM
Instrucciones de seguridad importantes
• No intente usar el PDU si se daña cualquier parte.
• No se recomienda el uso de este equipo en aplicaciones de soporte de vida en donde la falla de este equipo pueda consecuentemente causar la falla del equipo de soporte de vida o afectar significativamente su seguridad o efectividad.
Instalación
Nota: El usuario debe determinar la idoneidad de los materiales y accesorios así como de los procedimientos antes del montaje. La PDU y el material incluido están diseñados para racks (bastidores) y cajas de rack (bastidor) comunes, y pueden no ser apropiados para todas las aplicaciones.
1A
Configuración Cero U para Rack (Soportes de Montaje). Antes de
la instalación determine la ubicación en el rack en donde el PDU va a ser instalado. Fije los soportes de montaje al respaldo del PDU utilizando los tornillos incluidos, como se muestra. A fin de facilitar una colocación adecuada, cada soporte tiene cuatro perforaciones para los tornillos; asegúrese que las mismas dos perforaciones son usadas para fijar cada soporte al PDU. Después de fijar los soportes, coloque el PDU en su lugar en el rack y móntelo instalando cuatro tornillos, suministrados por el usuario, a través de los soportes en el rack.
1A
1B
Configuración para bastidor Cero U (Botones de Montaje). Fije los botones
de montaje, incluidos, al PDU. Coloque el PDU en la posición deseada en el bastidor, alinee los botones con las ranuras de montaje del bastidor, deslice
1B
el PDU para posicionarlo correctamente.
1C
Configuración Bajo el Escritorio. El
PDU puede instalarse bajo un escritorio utilizando los soportes de montaje incluidos. Fije los soportes de montaje a la parte trasera del PDU como se muestra en el paso 1A. Asegure el PDU abajo del escritorio instalando dos tornillos, suministrados por el usuario, a través de soporte en el escritorio.
1C
8
18-11-318-933312.indb 8 3/20/2019 1:22:54 PM
Características
Tomacorrientes: Durante la operación normal, los tomacorrientes distribuyen energía de CA al equipo conectado.
IEC-60320-C13
IEC-60320-C19
Clavija de Entrada: El cable está conectado permanentemente al PDU y tiene una clavija IEC 309 de 16A.
Amperímetro: La corriente eléctrica total usada por la unidad de distribución de potencia (PDU) será mostrada en el medidor digital, en amperios.
Accesorio de Instalación PDUMVROTATEBRKT: Use estos soportes con perfil en V para instalar el PDU con sus tomacorrientes viendo a la parte posterior del rack.
Soportes de Instalación: Use estos soportes para instalar el PDU.
Botones de Instalación: Vienen instalados en el lado posterior del
PDU y se usan para instalación sin herramienta. Nota: Se incluyen cuatro Botones de Instalación adicionales para estilos alternos de rack.
Manguito de Clavija C14: (Opcional) Use los manguitos plásticos C14 incluidos para asegurar las clavijas a los tomacorrientes. Acople el manguito a la clavija asegurándose que las pestañas de tiro permanezcan fuera de la clavija y que la sujeción sea segura. Para desenchufar correctamente el equipo, use las pestañas de tiro para retirar la clavija y el manguito del tomacorriente.
Manguito de Clavija C20: (Opcional) Use los manguitos plásticos C20 incluidos para asegurar las clavijas a los tomacorrientes. Acople el manguito a la clavija asegurándose que las pestañas de tiro permanezcan fuera de la clavija y que la sujeción sea segura. Para desenchufar correctamente el equipo, use las pestañas de tiro para retirar la clavija y el manguito del tomacorriente.
9
18-11-318-933312.indb 9 3/20/2019 1:22:55 PM