Tripp Lite PDUMVR20NETLX User Manual

Page 1
1.9kW Single-Phase Switched PDU, LX Platform, Outlet Monitoring, 120V Outlets (24 NEMA 5­15/20R), L5-20P Plug, 0U, TAA
MODEL NUMBER: PDUMVR20NETLX
1.9kW vertical PDU with individual outlet metering distributes, monitors and manages single-phase power. Built-in Java-free network interface helps you remotely monitor load levels to prevent overloads that cause downtime.
Description
The switched PDU features 24 individually controllable NEMA 5-15/20R outlets with cord retention brackets to prevent cables from becoming accidentally disconnected. A 10-ft. (3.05 m) power cord with NEMA L5-20P plug and optional 5-20P adapter connects the PDU to an AC source, generator or protected UPS.
Highlights
1.9kW 120V single-phase switched 70-inch 0U PDU
24 controllable NEMA 5-15/20R outlets in 2 load banks
Pre-installed WEBCARDLX with latest version of PADM20 for IP­based Auto Probe feature
Digital ammeter for on-site load monitoring in real time
10-ft. (3.05 m) power cord with NEMA L5-20P plug and 5-20P adapter
Package Includes
PDUMVR20NETLX 1.9kW Single-Phase Switched PDU
Built-in LX Platform interface
NEMA 5-20P plug adapter
Configuration cable
Cord retention brackets
(24) Cable ties
Rack-mounting hardware
PDUMVROTATEBRKT mounting bracket accessory
Owner’s manual
The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
A digital ammeter allows you to monitor each load bank's current, each outlet's current and the total connected PDU load in real time to ensure they remain well below maximum capacity with no danger of overload. The switched PDU mounts in 0U of space in EIA-standard 19-inch racks using the included toolless mounting buttons or the included rack-mounting brackets.
1 / 4
Page 2
Features
Distributes, Monitors and Manages Network-Grade AC Power1.9kW 120V 20A switched PDU with
single-phase input10-ft. (3.05 m) power cord with NEMA L5-20P plug and 5-20P adapterFirmware upgrades support future product enhancements 24 NEMA 5-15/20R Switched Outlets Distribute AC PowerIndividual outlets can be remotely controlled to power up, power down, reboot or lock out devicesIncluded cord retention brackets prevent cables from becoming accidentally disconnected Digital AmmeterReports current for each load bank, each individual outlet, and total PDU loadSupports IP-address self-IDDigits flip 180° for easy reading at either angle Built-In LX Platform InterfacePre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurationsIP­based Auto Probe detects lost connectivity and restores service autonomously Broad Communications CompatibilitySupports IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2c, SNMPv3, telnet, SSH, CLI, FTP, DHCP and NTPSupports automatic and manual assignment of IP address Essential Safety FeaturesTiered access allows administrator and guest to log in via web browserImmediate alert notifications via email or SNMP trapsSupports user-specified alarm notification thresholdsReal-time clock backup maintains day/date even if PDU is unpowered Easy 0U Installation in EIA-Standard 19 in. Racks70 in. PDU mounts vertically using included toolless buttons or rack-mounting bracketsIncluded PDUMVROTATEBRKT allows mounting with rear-facing outlets
TAA-CompliantCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Specifications
OVERVIEW
UPC Code 037332204141 PDU Type Switched
INPUT
PDU Input Voltage 120V Recommended Electrical Service Single-phase 20A 120V service Maximum Input Amps 16 Maximum Input Amps Details Agency de-rated to 16A continuous PDU Plug Type NEMA 5-20P; NEMA L5-20P Input Phase Single-Phase Input Cord Length (ft.) 10 Input Cord Length (m) 3.05
OUTPUT
Output Capacity Details 1.92kW (120V) / 16A total capacity; 16A max per outlet Frequency Compatibility 50 / 60 Hz Output Receptacles (24) 5-15/20R Output Nominal Voltage 120V
2 / 4
Page 3
Overload Protection n/a Customized Load Management
Receptacles
Each outlet is individually controllable via remote interface
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports load level in amps for LOAD BANK 1 (Outlets 1-12), LOAD BANK 2 (Outlets 13-24), LOAD
BANKS 1&2 COMBINED (Outlets 1-24) and each individual output receptacle; Digital display can also be used to scroll the configured IP address
Front Panel LEDs BANK 1 and BANK 2 LEDs verify which load bank the digital current display is reporting (Bank 1, Bank 2 or Banks
1&2 Combined); BANK 1 or BANK 2 LED will flash when the digital display is reporting output current for one of the outlets in that load bank; 24 additional LEDs, one near each output receptacle, will light continuously to verify power on/off status and flash to indicate that the digital display is reporting output current for just that individual receptacle. LX Platform Interface: Network Link/Activity Status LED (Yellow), Network Speed LED (Green); LX Platform status LED (Green)
Switches SELECT OUTLET and SELECT BANK switches advance the LCD screen and associated LED to display power
consumption for individual output receptacles and output load banks; Press and hold the SELECT BANK button for 4 seconds to rotate the digital display 90 degrees for overhead power input; Press and hold the SELECT OUTLET button for 4 seconds to scroll the configured IP address. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Current Measurement Accuracy (Amps)
Voltage Measurement Accuracy (Volts)
Power Measurement Accuracy (Watts)
+/-1%
+/-1%
+/-1%
PHYSICAL
Form Factors Supported 0U vertical rackmount; includes rackmount brackets. Supports toolless mounting in button-mount compatible racks PDU Form Factor Vertical (0U) Shipping Dimensions (hwd / cm) 11.51 x 15.49 x 192.48 Shipping Dimensions (hwd / in.) 4.53 x 6.10 x 75.78 Shipping Weight (kg) 6.77 Shipping Weight (lbs.) 14.93 Unit Dimensions (hwd / cm) 178 x 5.6 x 5.2 Unit Dimensions (hwd / in.) 70 x 2.2 x 2.04 Unit Weight (kg) 4.35 Unit Weight (lbs.) 9.6
ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F) Storage Temperature Range -30°C to +60°C (-22°F to +140°F) Relative Humidity 5 to 95% non-condensing
COMMUNICATIONS
3 / 4
Page 4
Network Monitoring Port RJ45 Network port, RJ45 Config/Console Access port; USB A port supports a variety of Envirosense2 environmental
and control modules. See Accessories>Management Hardware section for more information about these modules.
SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and
SPECIAL FEATURES
High Availability PDU Features Auto Probe Monitoring and Reboot (included)
STANDARDS & COMPLIANCE
Certifications Tested to UL60950-1: 2007 R12.11 (USA), CAN/CSA-C22.2 NO. 60950-1-07+A1: 2011(Canada), FCC CLASS A
WARRANTY
Product Warranty Period (Worldwide)
SNMP management systems
PART 15 (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
2-year limited warranty
© 2021 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies: https://www.tripplite.com/products/product-certification-agencies
4 / 4
Loading...