Tripp Lite PDUMV30HV2 User Manual

5.8kW Single-Phase Metered PDU, 208/240V Outlets (8 C19 and 40 C13), L6-30P, 10 ft. Cord, 0U Vertical, TAA, 70 in.
MODEL NUMBER: PDUMV30HV2
Distributes 30A single-phase AC power to as many as 48 servers, routers, switches and other networking rack equipment. Features digital ammeters for real-time monitoring of load levels to prevent overloads.
Description
The 70-inch (178-centimeter) PDUMV30HV2 30A 208/240V 5.8kW Single-Phase Metered Power Distribution Unit features 48 outlets for distributing single-phase AC power to rack-mounted equipment, including computers, routers, switches and servers.
Highlights
Ideal for server rooms, network closets and data centers
Dual load banks with 24 outlets each (4 C19 and 20 C13)
Dedicated 20A circuit breakers protect output
NEMA L6-30P input plug with 10-ft. (3 m) cord
Ready for immediate toolless 0U installation
Outlets are arranged in two separate load banks, each with 24 outlets (4 C19 and 20 C13), a dedicated 20A circuit breaker and a digital meter that reports the bank’s real-time output current in amps. The ammeters let you visually monitor each bank and maintain balanced loads to prevent circuit overloads and downtime due to breakers tripping. Special guards prevent the breakers from tripping accidentally. Outlets, breakers and ammeters are color-coded and labeled for easy identification.
An ideal PDU for server rooms, network closets and data centers, the PDUMV30HV2’s all-metal housing comes ready to mount vertically in your rack using the preinstalled 9 mm buttons or the included hardware. The NEMA L6-30P input plug with 10-foot (3-meter) cord connects to your facility’s compatible AC power source, generator or protected UPS. Included C20 and C14 plug-lock inserts connect to your components’ plugs to ensure they remain connected and continuously powered. Use the included ground screw to connect any equipment that requires a chassis ground.
Features
Digital Meters Help Prevent Overloads
Dual digital ammeters report real-time output current in amps
Visual monitoring of PDU load level prevents overloading as more equipment is connected
Distributes Plenty of Single-Phase Power
30A 208/240V 5.8kW metered PDU (agency derated to 24A continuous)
Dual load banks with separate 20A circuit breakers and digital ammeters
48 outlets—24 per bank (4 C19 and 20 C13)—distribute single-phase power to connected equipment
Special guards prevent breakers from accidentally tripping
Each bank is color-coded and labeled for convenient identification
Package Includes
PDUMV30HV2 30A 208/240V
5.8kW Single-Phase Metered PDU
Plug-lock inserts (8 C20, 40 C13)
Spare installation buttons, 2.9 mm/4.6 mm
Ground screw
Mounting hardware
Owner’s Manual
Connects to AC Power Source
NEMA L6-30P input plug with 10 ft. (3 m) cord for easy connection to main power source, generator or protected UPS
Included plug-lock inserts ensure components remain connected and powered
Included ground screw for equipment requiring chassis ground
1 / 3
Easy to Mount With or Without Tools
Ready for immediate toolless 0U installation using preinstalled 9 mm mounting buttons (spare 2.9 mm and 4.6 mm buttons included)
Nut-and-bolt vertical installation possible with included mounting hardware
Use included PDUMVROTATEBRKT mounting accessory for installation with outlets facing rear
TAA-Compliant
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Specifications
OVERVIEW
UPC Code 037332182807 PDU Type Metered
OUTPUT
Frequency Compatibility 50 / 60 Hz Output Capacity Details 5.8kW (240V), 5kW (208V), 4.8kW (200V) total capacity / 30A max (Agency de-rated to 24A), 20A max per
Output Receptacles (40) C13; (8) C19 Output Nominal Voltage 200; 208; 240 Overload Protection Two 20A breakers protect 24 outlets each
INPUT
PDU Input Voltage 200; 208; 240 Recommended Electrical Service 30A 208/240V Maximum Input Amps 30 Maximum Input Amps Details Agency de-rated to 24A continuous PDU Plug Type NEMA L6-30P Input Phase Single-Phase Input Cord Length (ft.) 10 Input Cord Length (m) 3.05
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments Supports local monitoring of output current for each output load bank; Outlets, circuit breakers and current meters
breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet
are color-coded and labeled for easy identification (Black: 20A Bank 1 / Gray: 20A Bank 2)
Front Panel LCD Display Set of two digital current meters report output current in two segments