Tripp Lite PDUMH32HVATNET User Manual

7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA
MODEL NUMBER: PDUMH32HVATNET
High-capacity 7.7kW 200-240V PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. LED display and LX Platform network interface enables remote outlet control and monitoring of site power status and PDU load levels.
Description
Highlights
Single-phase IEC309 200-240V 32A Blue (2P+E) input
16 C13 and 2 C19 230V switched outlets in 2 breakered load banks
Automatic transfer switching within 1–5 ms
Ethernet network interface for remote access
Digital LED display for real-time status and current monitoring
Package Includes
PDUMH32HVATNET 7.7kW Single-Phase 200-240V ATS / Switched PDU
Rack-mounting brackets
Plug-lock cable retention sleeves
USB configuration cable
Owner’s manual
Features
Primary and Secondary Inputs for Power RedundancyProvides remote power monitoring and enables
redundant power for network devices single-corded and other non-redundant power supply configurationsDual 3m input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources Automatic Transfer SwitchingDynamic solid-state (TRIAC) automatic transfer switchingSwitches to secondary power source if primary source fails or becomes unstable1–5 ms transfer time ensures uninterrupted operation of connected equipmentBuilt-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source Multifunction Digital LED DisplayReports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor Advanced LX Platform InterfaceLX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSHReal-time load/current data with billing-grade accuracy (+/- 1 percent)Automated alerts help prevent accidental overloads, power loss and
1 / 4
downtimeOptional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities Broad Communications CompatibilityProtocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP Breaker Protected Output Load BanksProtect each of 2 single-phase output banksFront-panel LED indicates when breaker has tripped Cord Retention SleevesSet of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices Mounts Horizontally in 2U of Rack SpaceCompatible with EIA-standard 19 in. 4-post racks and rack enclosures
TAA-CompliantCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases
Specifications
OVERVIEW
UPC Code 037332186874 PDU Type Switched; Auto-Transfer Switch
INPUT
PDU Input Voltage 200-240V Recommended Electrical Service Two single-phase 32A 200-240V circuits Maximum Input Amps 32 PDU Plug Type (2) IEC-309 32A BLUE (2P+E) Input Phase Single-Phase Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources; accepts inputs at all phase
Input Cord Length (ft.) 10 Input Cord Length (m) 3.05
OUTPUT
Output Capacity Details 7.7kW (240V), 7.4kW (230V), 7.0kW (220V), 6.7kW (208V), 6.4kW (200V); 32A maximum total output; 16A
Frequency Compatibility 50 / 60 Hz Output Receptacles (16) C13; (2) C19 Output Nominal Voltage 200-240V Overload Protection Includes two branch-rated 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19);
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Digital display reports output amps in 3 separately metered load segments (BANK 1: Outlets #1-9; BANK 2: Outlets
angles
maximum per breakered load bank; 16A maximum per C19 outlet; 10A maximum per C13 outlet
Breaker 2 controls the lower row of outlets (8 C13, 1 C19)
#10-18; BANK 3: Total Output), whole-PDU output kW load level and input voltage on primary and secondary input lines
Front Panel LEDs Front panel LEDs confirm amp / kilowatt / voltage reporting information
2 / 4
Loading...
+ 2 hidden pages