Tripp Lite PDUMH32HVATNET User Manual

Tripp Lite PDUMH32HVATNET User Manual

7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA

MODEL NUMBER: PDUMH32HVATNET

High-capacity 7.7kW 200-240V PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. LED display and LX Platform network interface enables remote outlet control and monitoring of site power status and PDU load levels.

Description

The PDUMH32HVATNET 7.7kW Single-Phase 200-240V Switched Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIAstandard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.

Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources.

Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.

Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.

Features

Primary and Secondary Inputs for Power RedundancyProvides remote power monitoring and enables redundant power for network devices single-corded and other non-redundant power supply configurationsDual 3m input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources

Automatic Transfer SwitchingDynamic solid-state (TRIAC) automatic transfer switchingSwitches to secondary power source if primary source fails or becomes unstable1–5 ms transfer time ensures uninterrupted operation of connected equipmentBuilt-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Multifunction Digital LED DisplayReports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor

Advanced LX Platform InterfaceLX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSHReal-time load/current data with billing-grade accuracy (+/- 1 percent)Automated alerts help prevent accidental overloads, power loss and

Highlights

Single-phase IEC309 200-240V 32A Blue (2P+E) input

16 C13 and 2 C19 230V switched outlets in 2 breakered load banks

Automatic transfer switching within 1–5 ms

Ethernet network interface for remote access

Digital LED display for real-time status and current monitoring

Package Includes

PDUMH32HVATNET 7.7kW Single-Phase 200-240V ATS / Switched PDU

Rack-mounting brackets

Plug-lock cable retention sleeves

USB configuration cable

Owner’s manual

1 / 4

downtimeOptional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities

Broad Communications CompatibilityProtocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP

Breaker Protected Output Load BanksProtect each of 2 single-phase output banksFront-panel LED indicates when breaker has tripped

Cord Retention SleevesSet of Plug-lock output power cable retention sleeves prevent accidental disconnection of connected devices

Mounts Horizontally in 2U of Rack SpaceCompatible with EIA-standard 19 in. 4-post racks and rack enclosures

TAA-CompliantCompliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Specifications

OVERVIEW

UPC Code

037332186874

 

 

PDU Type

Switched; Auto-Transfer Switch

 

 

INPUT

 

PDU Input Voltage

200-240V

 

 

Recommended Electrical Service

Two single-phase 32A 200-240V circuits

 

 

Maximum Input Amps

32

 

 

PDU Plug Type

(2) IEC-309 32A BLUE (2P+E)

 

 

Input Phase

Single-Phase

 

 

Input Cord Details

Set of two inputs connect to separate PRIMARY and SECONDARY power sources; accepts inputs at all phase

 

angles

 

 

Input Cord Length (ft.)

10

 

 

Input Cord Length (m)

3.05

 

 

OUTPUT

 

Output Capacity Details

7.7kW (240V), 7.4kW (230V), 7.0kW (220V), 6.7kW (208V), 6.4kW (200V); 32A maximum total output; 16A

 

maximum per breakered load bank; 16A maximum per C19 outlet; 10A maximum per C13 outlet

 

 

Frequency Compatibility

50 / 60 Hz

 

 

Output Receptacles

(16) C13; (2) C19

 

 

Output Nominal Voltage

200-240V

 

 

Overload Protection

Includes two branch-rated 20A output circuit breakers; Breaker 1 controls the upper row of 9 outlets (8 C13, 1 C19);

 

Breaker 2 controls the lower row of outlets (8 C13, 1 C19)

 

 

USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display

Digital display reports output amps in 3 separately metered load segments (BANK 1: Outlets #1-9; BANK 2: Outlets

 

#10-18; BANK 3: Total Output), whole-PDU output kW load level and input voltage on primary and secondary input

 

lines

 

 

Front Panel LEDs

Front panel LEDs confirm amp / kilowatt / voltage reporting information

 

 

2 / 4

Loading...
+ 2 hidden pages