Tripp Lite PDUMH32HV User Manual

7.4kW Single-Phase Metered PDU, 230V Outlets (2-C19, 16-C13), IEC-309 230V 32A Blue, 12 ft. (3.66 m) Cord, 2U Rack-Mount, TAA
MODEL NUMBER: PDUMH32HV
Features
32A single phase 230V Metered Power Distribution Unit / PDU
Set of two lighted current meters separately report power consumption in amps for each output load bank
Attached IEC-309 32A (2P+E) input plug with 12-ft. (3.66 m) line cord
2U horizontal rackmount format installs in two rack spaces
18 total 230V outlets (2 C19, 16 C13)
Outlets are arranged in two separately breakered and metered 16A load banks (each with 8 C13 and 1 C19 outlet)
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
Mounting ears are reversible for front or rear facing rackmount installation
Front-panel grounding lug
Included cord retention brackets
Highlights
Metered single phase 32A 230V 2U horizontal rackmount PDU
Set of 2 current meters reports current in amps for each output load bank
Attached 12-ft. (3.66 m) cord with IEC-309 32A (2P+E) input plug
18 total 230V outlets (2 C19, 16 C13)
Reversible housing, 12.5 in. /
31.75cm depth
TAA Compliant
Package Includes
2U metered PDU
Mounting brackets
Plug retention brackets
User manual
Specifications
OVERVIEW
UPC Code 037332159045 PDU Type Metered
1 / 3
INPUT
PDU Input Voltage 230V Recommended Electrical Service Single-phase 32A 230V service Maximum Input Amps 32 PDU Plug Type IEC-309 32A BLUE (2P+E) Input Phase Single-Phase Input Cord Length (ft.) 12 Input Cord Length (m) 3.66
OUTPUT
Output Capacity Details 7.4kW (230V) / 32A total capacity / 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13
outlet Frequency Compatibility 50 / 60 Hz Output Receptacles (16) C13; (2) C19 Output Nominal Voltage 230V Overload Protection Two 20A circuit breakers protect 9 outlets each
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Set of 2 digital meters continuously report output current for breakered load bank; Bank 1 (Upper row of 9 outlets),
Bank 2 (Lower row of 9 outlets) Switches n/a
PHYSICAL
Form Factors Supported 2U rackmount Material of Construction Metal Minimum Required Rack Depth (cm) 40.64 Minimum Required Rack Depth
(inches)
16
PDU Form Factor Horizontal (2U) Shipping Dimensions (hwd / cm) 19.81 x 42.67 x 49.02 Shipping Dimensions (hwd / in.) 7.80 x 16.80 x 19.30 Shipping Weight (kg) 6.67 Shipping Weight (lbs.) 14.70 Unit Dimensions (hwd / cm) 8.9 x 44.5 x 31.75 Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5 Unit Weight (kg) 6.21 Unit Weight (lbs.) 13.7
2 / 3
Loading...
+ 1 hidden pages