7.4kW Single-Phase Metered PDU, 230V Outlets
(2-C19, 16-C13), IEC-309 230V 32A Blue, 12 ft.
(3.66 m) Cord, 2U Rack-Mount, TAA
MODEL NUMBER: PDUMH32HV
Features
●
32A single phase 230V Metered Power Distribution Unit / PDU
●
Set of two lighted current meters separately report power consumption in amps for each output load
bank
●
Attached IEC-309 32A (2P+E) input plug with 12-ft. (3.66 m) line cord
●
2U horizontal rackmount format installs in two rack spaces
●
18 total 230V outlets (2 C19, 16 C13)
●
Outlets are arranged in two separately breakered and metered 16A load banks (each with 8 C13 and 1
C19 outlet)
●
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and
under-counter installation formats
●
Mounting ears are reversible for front or rear facing rackmount installation
●
Front-panel grounding lug
●
Included cord retention brackets
Highlights
●
Metered single phase 32A 230V
2U horizontal rackmount PDU
●
Set of 2 current meters reports
current in amps for each output
load bank
●
Attached 12-ft. (3.66 m) cord
with IEC-309 32A (2P+E) input
plug
●
18 total 230V outlets (2 C19, 16
C13)
●
Reversible housing, 12.5 in. /
31.75cm depth
●
TAA Compliant
Package Includes
●
2U metered PDU
●
Mounting brackets
●
Plug retention brackets
●
User manual
Specifications
OVERVIEW
UPC Code 037332159045
PDU Type Metered
1 / 3

INPUT
PDU Input Voltage 230V
Recommended Electrical Service Single-phase 32A 230V service
Maximum Input Amps 32
PDU Plug Type IEC-309 32A BLUE (2P+E)
Input Phase Single-Phase
Input Cord Length (ft.) 12
Input Cord Length (m) 3.66
OUTPUT
Output Capacity Details 7.4kW (230V) / 32A total capacity / 16A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13
outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (16) C13; (2) C19
Output Nominal Voltage 230V
Overload Protection Two 20A circuit breakers protect 9 outlets each
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Set of 2 digital meters continuously report output current for breakered load bank; Bank 1 (Upper row of 9 outlets),
Bank 2 (Lower row of 9 outlets)
Switches n/a
PHYSICAL
Form Factors Supported 2U rackmount
Material of Construction Metal
Minimum Required Rack Depth (cm) 40.64
Minimum Required Rack Depth
(inches)
16
PDU Form Factor Horizontal (2U)
Shipping Dimensions (hwd / cm) 19.81 x 42.67 x 49.02
Shipping Dimensions (hwd / in.) 7.80 x 16.80 x 19.30
Shipping Weight (kg) 6.67
Shipping Weight (lbs.) 14.70
Unit Dimensions (hwd / cm) 8.9 x 44.5 x 31.75
Unit Dimensions (hwd / in.) 3.5 x 17.5 x 12.5
Unit Weight (kg) 6.21
Unit Weight (lbs.) 13.7
2 / 3

ENVIRONMENTAL
Operating Temperature Range 0C ~ 40C (32F ~ 104F)
Storage Temperature Range -30°C to +50°C (-22°F to +122°F)
Relative Humidity 5 to 95% non-condensing
STANDARDS & COMPLIANCE
Certifications Tested to CE (IEC 60950-1), UL, CSA, Class A, RoHS compliant, TAA Compliant
WARRANTY
Product Warranty Period
(Worldwide)
2-year limited warranty
© 2021 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does
not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite's testing agencies:
https://www.tripplite.com/products/product-certification-agencies
3 / 3