Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: PDUMH15AT
Single-Phase Auto Transfer Switch / Metered PDU, 15A 120V, 1U Horizontal Rackmount, 8 NEMA 5-15R
outlets, 2 NEMA 5-15P inputs
Highlights
Single phase 15A 120V Auto Transfer Switch / ATS PDU
Enables redundant-power option for single-corded network devices
Separate primary & secondary inputs connect to any two compatible power
sources
1U horizontal rackmount; 2 NEMA 5-15P inputs; 8 NEMA 5-15R outlets
Two digit visual current meter; Upgrade options available
Description
Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support
separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from
the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source
until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS
functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power
networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when
each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave
UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS
configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS
processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality
than the primary source. Front input LED's display primary or secondary power availability.
Applications
Ideal means to provide single-corded network gear a redundant power option
Package Includes
PDU with attached 5-15P primary input cord
Detachable C13 to NEMA 5-15P 12 ft / 3.6m secondary input cord
1U mounting brackets
User manual with warranty information
Features
120V 15A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 12A continuous)
Provides a redundant power option for critical networking equipment with a single input power cord
2 digit display reports output power consumption in amps
1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
8 built-in NEMA 5-15R outlets
Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will
switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection
when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an
online UPS with zero transfer time similar to Tripp Lite SmartOnline series)