Tripp Lite IS1800HG User Manual

Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: IS1800HG
Highlights
Complete line isolation, noise filtering and surge suppression; ideal for
sensitive equipment
1800 watts, 6 outlets, 10-ft. power cord
Hospital-grade plug and receptacles
Leakage current less than 100 microamps
Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule
purchases
Description
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-20P Hospital Grade; Output - 6 NEMA 5-20R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 2.1A (Requires NEMA 5-15R wall receptacle)
Package Includes
IS1800HG Isolation Transformer
NEMA5-15P replacement plug
User manual with warranty information
Features
The IS1800HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering
Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for
the protection of sensitive electronic equipment in patient-care areas.
Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral to
ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
Serves as an inexpensive alternative to dedicated circuits and site electrical upgrades
Removes EMI/RFI noise, utility switching transients, load-generated harmonics and ground loops
Active transformer filtering offers continuous common-mode noise rejection with no wearable parts; unique ability to reduce surges in the
worst of power environments to harmless levels
Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
Includes 6 widely spaced NEMA5-20R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker
overload protection, and lighted power switch
Ships with NEMA5-20P input plug installed, package includes NEMA5-15P user-installable hospital-grade replacement plug for compatiblity
with common 15A wall receptacles
Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Specifications
OVERVIEW
Amp Capacity 15A at 120V AC
Efficiency 96%
Form Factor Small tower format
Input Plug Type NEMA 5-20P-HG
Leakage Current Less than 100 microamps
Let-through Voltage (Combination Wave)
L-N: 250V L-G: 250V N-G: 0.5V
Let-through Voltage (Ring Wave)
L-N: 20V L-G: 20V N-G: 0.5V
Noise Suppression Rating 35-65 DB
Nominal Voltage / Frequency 120V / 60Hz
Output Receptacle Qty / Type 6 NEMA 5-20R-HG
Over Current Protection 1x thermal, 2 pole, 10 amp
Shipping Weight 58.00 lbs. / 26.31 kg
Suppression Joule Rating 1190 (1020 input / 170 output)
Surge Test Conditions Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms
Total Harmonic Distortion Less than 1%
Transformer Type Hospital Grade, low impedance transformer-based line isolation transformer
Unit Dimensions (HWD/in.) 7.75 x 8.25 x 12.25
VA / Watt Capacity 1800
INPUT
Input cord length (ft.) 10
Input cord length (m) 3.05
PHYSICAL
Cooling method Convection
Unit Dimensions (HWD/cm) 19.69 x 20.96 x 31.11
CERTIFICATIONS
Certifications Tested to UL60601-1
WARRANTY
Product Warranty Period (Worldwide)
2-year limited warranty
Loading...
+ 1 hidden pages