Owner's Manual
SmartPro
1111 W. 35th Street
Chicago, IL 60609 USA
Customer Support: (773) 869-1234
www.tripplite.com
Safety: p. 2
2200XLT
Line-Interactive
UPS Systems (230V)
Installation: p. 3 - 4
®
Basic Operation: p. 4 - 6
Storage & Service: p. 7
Specifications: p. 7
Warranty & Insurance: p. 6
Copyright © 1999 Tripp Lite. All rights reserved. SmartPro® is a registered trademark of Tripp Lite.
1
Safety
This manual contains important instructions and warnings that should be
followed during the installation, operation and storage of all Tripp Lite UPS
Systems.
UPS Location Warnings
• Install your UPS indoors, away from excess moisture or heat, dust or
direct sunlight.
• For best performance, keep the indoor temperature between 32° F and
104° F (between 0° C and 40° C).
• Leave adequate space around all sides of the UPS for proper ventilation.
UPS Connection Warnings
• Connect your UPS to a properly grounded AC power outlet. Do not
remove or modify the UPS's plug.
• Do not use two-prong adapters with the UPS's plug. Do not plug your
UPS into itself; this will damage the UPS and void your warranty.
• If you are connecting your UPS to a motor-powered AC generator,
the generator must provide clean, filtered computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life support applications in which
a malfunction or failure of a Tripp Lite UPS System could cause failure
or significantly alter the performance of a life-support device.
• Do not connect surge suppressors to the output of your UPS. This may
damage your UPS and will void both the surge suppressor and UPS
warranties.
Battery Warnings
• Your UPS does not require routine maintenance. Do not open your UPS
for any reason. There are no user-serviceable parts inside.
• Battery replacement must be performed by qualified service personnel.
Because the batteries present a risk of electrical shock and burn from
high short-circuit current, observe proper precautions. Unplug and turn
off the UPS before performing battery replacement. Use tools with
insulated handles and replace the existing batteries with the same
number and type of new batteries (Sealed Lead-Acid). Do not open the
batteries. Do not short or bridge the battery terminals with any object.
• The UPS batteries are recyclable. Refer to local codes for disposal
requirements or call 1-800-SAV-LEAD (1-800-728-5323) for complete
recycling information. Do not dispose of the batteries in a fire.
• Connect only Tripp Lite battery packs with the correct voltage (see voltage
requirements label on the rear of your UPS) and the correct connector color
to match your UPS’s External Battery Connector.
• Do not plug UPS in or operate without batteries.
2
Installation
Plug your UPS into
1
an electrical outlet.
The SmartPro 2200XLT should be connected to a
15-amp dedicated circuit.
Plug your equipment
2
into your UPS.
Your UPS is designed to support
only computer equipment.
Connecting household appliances,
laser printers or surge suppressors
is not recommended.
Turn your UPS ON.
3
Set the System Enable Switch (DIP
·
Switch #4, UPS back panel) to the
“ENABLE” (UP) position.
(See Figure 1)
This switch activates the battery charger and
microprocessor.
The “ ” light will flash until you engage the
ON/Standby Switch to activate the “ON” mode.
Engage the momentary ON/Standby
·
Switch (UPS front panel) and release it
to activate the “ON” mode and supply
power to the UPS receptacles.
(See Figure 2)
Figure 1
ENABLE
DISABLE
Figure 2 - ON/Standby Switch
DB9 Port Connection (Optional) On Next Page . . .
DIP Switch #4
(System Enable Switch)
3