User Manual
Preface
Carefully read this user manual prior to installing the matrix. Pictures shown in this manual is for reference only, different model and specifications are subject to real product. This manual is only for operational instruction only, not for maintenance purposes. Pictures shown in this manual are for reference only. Specifications are subject to change without notice. Please refer to the Triax website www.triax.uk
Trademarks
Any other trademarks mentioned in this manual are acknowledged as the properties of the trademark owner. No part of this publication may be copied or reproduced without the prior written consent of Triax.
FCC Statement
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. It has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. Operation of this equipment in a residential area may to cause interference, in which case the user at their own expense will be required to take whatever measures may be necessary to correct the interference. Any changes or modifications not expressly approved by the manufacture would void the user’s authority to operate the equipment.
2/52
SAFETY PRECAUTIONS
To ensure the best from the product, please read all instructions carefully before using the device. Keep this manual for further reference.
Unpack the equipment carefully and save the original box and packing material for possible future shipment.
Follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons.
Do not dismantle the housing or modify the module. It may result in electrical shock or burn.
Using supplies or parts not mee
ting the products specifications may cause damage, deterioration or
malfunction.
Refer all servicing to qualified service personnel.
To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.
Do not put any heavy items on the power cable to prevent damage.
Do not remove the housing of the device as opening or removing housing may expose you to dangerous voltage
or other hazards.
Install the device in a place with good ventilation to avoid damage caused by ov
erheating.
Keep the module away from liquids.
Spillage into the housing may result in fire, electrical shock, or equipment damage. If an object or liquid falls or
spills on to the housing, unplug the module immediately.
Do not use liquid or aerosol cleaners to clean this unit. Always unplug the power to the device before cleaning.
Unplug the power cord when left unused for a long period of time.
Information on disposal for scrapped devices: do not burn or mix with general household waste
, please treat them
as normal electrical wastes.
3/52
User Manual
Contents
Preface 2
Trademarks 2
FCC Statement 2
Safety Precautions 3
Contents 4
Contents Continued 5
1. Introduction 6
1.1 Introduction to the Triax Matrices 6
1.2 Features 6
1.3 Packing Lists 7
1.3.1 Packing List HMX 442LP4K (310037) 7
1.3.2Packing List HMX 663LP4K (310047) 7
1.3.3 Packing List HMX 884LP4K (310038) 7
2.1 Product Appearance HMX 442LP4K (310037) 8
2.1 .1Front Panel 8
2.1.2 Rear Panel 8
2.1.3 Rear Panel– Continued 9
2.2 Product Appearance HMX 663LP4K (310047) 10
2.2.1 Front Panel 10
2.2.2 Rear Panel 11
2.3 Product Appearance HMX 884LP4K (310038) 12
2.3.1 Front Panel 12
2.3.2 Rear Panel 13
3. System Connection 14
3.1 System Applications 14
3.2 Usage Precautions 14
3.3 Connection Diagram 14
3.3.1 HMX 442LP4K (310037) Connection Diagram 14
3.3.2 HMX 663LP4K (310047) Connection Diagram 14
3.3.3 HMX 884LP4K (310038) Connection Diagram 15
3.4 Connection Procedure 15
3.5 Connection to HDBaseT™ HRX 1LP4K receiver (310039) 16
4.System Operations 17
4.1 Front Panel Button Control 17
4.1.1 Switching I/O connection 17
4.1.2 EDID Management 18
4.1.3 EDID Invoking 19
4.1.4 Enquiry 20
4.1.5 Clear Operation 20
4/52
5/52
4.2 IR Control 20
4.2.1 Usage of IR Remote 21
4.2.2 IR Operations 22
4.2.3 IR Matrix Bi-directional Control 22
4.2.4 IR Control Setting 23
4.2.5 Control Local Device From Viewing Area or Zone 24
4.3 RS232 Control 24
4.3.1 Connection with RS232 Communication Port 24
4.3.2 Installation / Uninstallation of RS 232 Control Software 25
4.3.3 Basic Settings 25
4.3.4 RS232 Communication Commands (HMX442LP4K) 26
4.3.4 RS232 Communication Commands - Continued 27
4.3.4 RS232 Communication Commands - Continued 28
4.3.4 RS232 Communication Commands - Continued 29
4.3.4 RS232 Communication Commands - Continued 30
4.3.4 RS232 Communication Commands - Continued 31
4.3.4 RS232 Communication Commands - HMX 663LP4K & HMX 884LP4K) 32~39
4.4 RS232 Control Modes 39
4.4.1 RS232 Control Modes– Control Triax Matrix Locally 40
4.4.2 RS232 Control Modes– Control Triax Matrix Zones 40
4.4.3 Control 3rd Party Device Locally 40
4.4.4 Bi-directional RS232 Control 41
4.5 TCP/IP Control 42
4.5.1 Control Modes 42
4.5.2 GUI for TCP/IP 43
4.5.2 GUI for TCP/IP Screen Grabs 44
4.5.2 GUI for TCP/IP Screen GrabsContinued 45
4.5.3 GUI Updates 45
4.4.4 Firmware Updates via USB 46
5. Specifications 47
6. Troubleshooting and Maintenance 48
6. Troubleshooting and Maintenance 49
7. After Sales Support 49
Contents Continued
User Manual
1. Introduction
1.1 Introduction to the Triax Matrices
The new range of Triax Matrices encompass the HMX 442LP4K, HMX 663LP4k and HMX 884LP4K are professional HDBaseT Matrix Switches that accommodate either 4, 6 or 8 HDMI inputs (4k signal resolution 3840 x 2160@30Hz at 40max), and the corresponding number of CAT5e/6/7 outputs, in addition all matrices have either 2, 3 or 4 simultaneous HDMI outputs to be used with local displays or AVR’s.
The Matrices enables the user to select any HDMI input by front panel buttons, IR, RS232, GUI or 3rd Party integration control. The selected source is delivered to the HDMI Outputs 1, 2, 3 or 4 individually or simultaneously and to the HDBaseT outputs 1~4, 1~6, 1~8 subject to model. The uncompressed signals are transmitted via the pre-installed CAT cabling infrastructure, it is recommended to use high quality CAT6 cable and avoid CCS type CAT cable. The signals can be received up to 70m for 1080p and a maximum of 40m at 4Kx2K@30Hz, 3840x2160@30Hz. All Triax matrices support EDID management, HDCP , bi-directional RS-232 and IR control.
Apart from the embedded HDMI audio, the Triax matrices provide auxiliary audio inputs. Audio source can be selected via RS232 command. The selected Source’s audio is simultaneously passed to both the HDMI and HDBaseT outputs, The HDBaseT signals are then converted back to HDMI, the HDMI cable can be plugged directly in to a display or local AVR.
1.2 Features
Support HDMI 1.4, 4Kx2K @30Hz & 1080p 3D
HDCP1.4 compatible, supports manual HDCP management and auto-detecting
Transmit 4Kx2K@30Hz signal for 8m via HDMI port, 40m via HDBT ports
Audio source selectable via RS232 command
Either 4, 6 or 8 HDBaseT™ CAT outputs, 70m at 1080p and 40m at 4Kx2K@30Hz on a single CAT5e/6 cable
Supports PoC (Power over Cable, PoE-Power over Ethernet or PoH-Power over HDBaseT™)
Real-time LCD status indication
Controllable via front panel, RS232, IR ,TCP/IP and or 3rd Party integration.
Supports bi-directional IR& RS232 control
Built-in GUI for TCP/IP control
Powerful EDID management
Retains settings after power cycle
Supports firmware upgrade through Micro USB port, available from Triax website, www.triax.uk
Rack-mount or desk top design
6/52
1.3.1 Package List– HMX 442LP4K (310037)
1 x HMX 442LP4K
2 x Mounting ears (6 x Screws)
1 x RS232 cable
1 x IR Receiver
4 x Plastic feet (4 x Black Screws)
1 x IR remote
1 x Plug-top power adapter (DC 24V 2.5A)
3 x interchangeable plugs EU, AU/NZ and UK
8 x Pluggable Terminal Blocks
4 x IR Transmitters
1 x Twin High Powered IR Blaster
1 x Multi-lingual User manual
1.3.2 Package List– HMX 663LP4K (310047)
1 x MHX 663LP4K
2 x Mounting ears (6 x Screws)
1 x RS232 cable
6 x IR Transmitters
1 x IR Receiver
1 x Twin High Powered IR Blaster
4 x Plastic feet (4 x Black Screws)
1 x IR Remote
3x Interchangeable power cords EU, AU/NZ and UK
18 x Pluggable Terminal Blocks
1 x Multi-lingual User Manual
1.3.3 Package List– HMX 884LP4K (310038)
1 x HMX 884LP4K
2 x Mounting ears (6 x Screws)
1 x RS232 cable
1 x IR Receiver
1 x Twin High Powered IR Blaster
8 x IR Transmitters
4 x Plastic feet (4 x Black Screws)
1 x IR remote
3x Power Cords EU, AU/NZ and UK
24 x Pluggable Terminal Blocks
1 x Multi-lingual User Manual
Notes: Please check the contents carefully that the matrix and the accessories are all included and undamaged, if not,
please contact your supplier. Do Not Use if the product is damaged.
7/52
User Manual
2.1 Product Appearance of the HMX 442LP4K (310037)
2.1.1 Front Panel
No. Name Description
Firmware Micro USB - firmware upgrade
Power Indicator
Illuminate Green when power on, Red in Standby
IR In-built IR sensor, receive IR signals sent from IR remote.
LCD Screen Displays real-time status indication.
INPUTS/ Menu buttons
Normal mode: ranging from "1" to "4". Enquiry mode (buttons 1~4): Press “ENTER for >3
seconds to enter mode. Press to select different menus, to select options, press ENTER to confirm.
OUTPUTS but­tons/ EDID Management buttons
Normal mode: ranging from "1" to "4". Output 1~2 support
synchronous local HDMI output.
EDID Invoking mode: press and hold EDID button for >3
seconds to enter mode, press buttons 1or
2, these switch to
the previous/next EDID data.
Function Buttons
ALL: Select all inputs / outputs
EDID management button: Enables input port to manually capture and select the EDID data of output device.
CLEAR: Cancel an operation, like switching output Channel or learning EDID data before it comes into effect. The matrix will return to the previous state.
ENTER: Confirms operation. Press and hold for >3 seconds to enter Enquiry mode.
1. Notes: Pictures shown in this manual are for reference only. Specifications are subject to change without notice.
2.1.2 Rear Panel
1 2
3
4
5
6
7
8/52
9/52
2.1.3 Rear Panel HMX 442LP4K (310037) continued
No. Name
Description
IR ALL IN
Pug the IR Receiver in to the 3.5mm jack socket. The allows IR signals to pass from the Matrix to each corresponding Receiver in the zone.
HDMI INPUTS 4 x HDMI type A female input sockets. Plug an HDMI cable from the
Source to any of the HDMI input Sockets.
IR OUT
Plug an IR transmitter into the 3.5mm jack socked marked up “IR OUT” on the matrix, ensure that the required zone is chosen, these are clearly marked up. The IR sig­nals are sent from the receiver in the zone to the matrix, these are passed through to enable control of the Source.
OUTPUTS
a. IR IN: Plug an IR receiver in to the “IR IN” 3.5mm socket on the matrix. The IR
Signals are sent from the matrix to the receiver on thought to the IR emitter.
b. COAX: HDMI de-embedded digital audio output
c.
RS232: Serial communications between matrix and the corresponding
HDBaseT™ receiver.
d. HDMI: HDMI Type A connectors, plug an HDMI cable in to the
output socket and connect it to either a local display or AVR.
e. HDBaseT™: Uses HDBT technology to convert HDMI to
CAT5e/6. Use with HRX 1LP4K receiver
f. Audio: HDMI de-embedded stereo audio output
IR All OUT
Plug IR Twin Blaster in to the 3.5mm jack marked as “IR ALL OUT”. This func-
tion allows IR signals to be sent from the zones back through the matrix to control 3rd party equipment such as AVR’s
TCP/IP
TCP/IP port for unit control
RS232
Serial port for unit control, 9-pin female connector, connects with control device such as a PC.
Power Indicator Front panel Illuminate Green when powered on and RED in Standby. RED
Power on Indicator on rear panel
DC24V
DC 24V power adaptor.
Ground
Ensure that the matrix is earth bonded
User Manual
10/52
2.2 Product Appearance of the HMX 663LP4K (310047)
2.2.1 Front Panel
2
3
4
5
6
7
1
No. Name Description
Firmware Micro USB firmware update
Power Indicator
Illuminate Green when power on Illuminate Red in standby mode
IR In-built IR sensor, receive IR signals sent from IR remote.
LCD Screen Display real-time operation status.
INPUTS/ Menu buttons
Normal mode: ranging from "1" to "6". Enquiry mode (buttons 1~4): Press ENTER” for >3 seconds to enter
mode. Press to select different menus, to select options. Press ENTER to confirm.
OUTPUTS buttons/ EDID Management buttons
Normal mode: ranging from "1" to "6". Output 1~3 support
Synchronous local HDMI output.
EDID control mode: press and hold EDID button for >3 seconds enter this
mode, buttons 1~6 correspond to the 6 embedded EDID data received from the displays. Press any of the 6 buttons to save the embedded EDID data.
Function Buttons
ALL: Select all inputs / outputs
EDID management button: Enables input port to manually capture and select the EDID data of output device.
CLEAR: Cancel an operation, like switching output Channel or learning EDID data before it comes into effect. The matrix will return to the previous state.
ENTER: Confirms operation. Press and hold for >3 seconds to enter Enquiry mode.
11/52
2.2 Product Appearance of the HMX 663LP4K (310047)
2.2.2 Rear Panel
INPUTS
b. AUDIO: Auxiliary audio input ports, 6 in total, compatible with
PCM audio sources
c. HDMI: 6 x HDMI type A female sockets. Plug an HDMI cable in to the
socket and repeat on the Source device (such as Blu-ray)
OUTPUTS
d. IR IN: The matrix has 6 “IR IN” 3.5mm sockets. These connect di-
rectly to the IR IN on the receivers. This forms a fixed bi-directional transmission link.
e. RS232: The matric has six 3-pin pluggable terminal blocks, these ena-
ble fixed communication link with the RS232 port on corre­sponding HDBaseTreceiver.
f. AUDIO: 6 x stereo audio outputs g. HDMI: HDMI Type A connectors, plug an HDMI cable into
the output socket and connect it to either a local display or AVR
.
h. HDBaseT: Uses HDBT technology to convert HDMI signals to
CAT5e/6
RS232
Serial port for unit control, 9-pin female connector, enables control of 3rd party device such as a PC.
IR ALL IN
Plug an IR Receiver in to the “IR ALL IN” 3.5mm jack socket. Sends IR
command signals from the matrix to the receivers.
TCP/IP TCP/IP port for unit control
IR ALL OUT
Receivers IR command signals from the receivers and re-transmits
the command signals to 3rd party devices such as AVR’s.
Power Button
Front panel Illuminate Green when powered on and RED in Standby. RED Power on Indicator on rear panel
Power Supply
Plug the power supply in to the Matrix, select to correct power cord for your region.
GROUND Ensure the Matrix is earth bonded.
No. Name
Description
INPUTS
a. IR OUT: Plug the IR emitters in to the “IR OUT” 3.5mm jack sockets.
This allows the IR signals to be passed through the matrix to the receiver in the select zone or to all zones. The default setting enables all corresponding inputs to be connected to their respective outputs, i.e. IR IN 1 to be linked to IR OUT 1.
User Manual
12/52
2.3 Product Appearance of the HMX 884LP4K (310038)
2.3.1 Front Panel
2
3
4
5
6
7
1
No. Name Description
Firmware Micro USB firmware update
Power Indicator
Illuminate Green when power on Illuminate Red in standby mode
IR In-built IR sensor, receive IR signals sent from IR remote.
LCD Screen Display real-time operation status.
INPUTS/ Menu buttons
Normal mode: ranging from "1" to "8". Enquiry mode (buttons 1~4): Press ENTER” for >3 seconds to enter
mode. Press to select different menus, to select options. Press ENTER to confirm.
OUTPUTS buttons/ EDID Management buttons
Normal mode: ranging from "1" to "8". Output 1~3 support
Synchronous local HDMI output.
EDID control mode: press and hold EDID button for >3 seconds enter this
mode, buttons 1~8 correspond to the 8 embedded EDID data received from the displays. Press any of the 8 buttons to save the embedded EDID data.
Function Buttons
ALL: Select all inputs / outputs
EDID management button: Enables input port to manually capture and select the EDID data of output device.
CLEAR: Cancel an operation, like switching output Channel or learning EDID data before it comes into effect. The matrix will return to the previous state.
ENTER: Confirms operation. Press and hold for >3 seconds to enter Enquiry mode.
13/52
2.3 Product Appearance of the HMX 884LP4K (310037)
2.3.2 Rear Panel
INPUTS
b. AUDIO: Auxiliary audio input ports, 8 in total, compatible with
PCM audio sources
c. HDMI: 8 x HDMI type A female sockets. Plug an HDMI cable in to the
socket and repeat on the Source device (such as Blu-ray)
OUTPUTS
d. IR IN: The matrix has 8 “IR IN” 3.5mm sockets. These connect
directly to the IR IN on the receivers. This forms a fixed bi-directional transmission link.
e. RS232: The matric has 8 x 3-pin pluggable terminal blocks, these
enable fixed communication link with the RS232 port on corresponding HDBaseTreceiver.
f. AUDIO: 8 x stereo audio outputs g. HDMI: HDMI Type A connectors, plug an HDMI cable into
the output socket and connect it to either a local display or AVR
.
h. HDBaseT: Uses HDBT technology to convert HDMI signals to
CAT5e/6
RS232
Serial port for unit control, 9-pin female connector, enables control of 3rd party device such as a PC.
IR ALL IN
Plug an IR Receiver in to the “IR ALL IN” 3.5mm jack socket. Sends IR
command signals from the matrix to the receivers.
TCP/IP TCP/IP port for unit control
IR ALL OUT
Receivers IR command signals from the receivers and re-transmits
the command signals to 3rd party devices such as AVR’s.
Power Button
Front panel Illuminate Green when powered on and RED in Standby. RED Power on Indicator on rear panel
Power Supply
Plug the power supply in to the Matrix, select to correct power cord for your region.
GROUND Ensure the Matrix is earth bonded.
No. Name
Description
INPUTS
a. IR OUT: Plug the IR emitters in to the “IR OUT” 3.5mm jack sockets.
This allows the IR signals to be passed through the matrix to the re­ceiver in the select zone or to all zones. The default setting enables all corresponding inputs to be connected to their respective outputs, i.e. IR IN 1 to be linked to IR OUT 1.
User Manual
14/52
3.3.2 HMX 663LP4K (310047) Connection Diagram
3. System Connection
3.1 System Applications
The Triax Matrices are ideal for Schools, Residential Pubs, Clubs and Sports Bars.
3.2 Usage Precautions
1. System should be installed in a clean environment.
2. Ensure that all of the power cords and plugs are not damaged, if there are any signs of damage DO NOT Use and send back to the Supplier.
3. All devices should be connected before power on.
3.3 System Connection Diagrams
3.3.1 HMX 442LP4K (310037) Connection Diagram
15/52
3.3.3 HMX 884LP4K (310038) Connection Diagram
3.4 Connection Procedure
1) Connect HDMI sources (e.g. DVD) to HDMI inputs of the Matrix with High Speed + Ethernet HDMI cables.
2) Connect auxiliary audio sources to the AUDIO IN ports with audio cables.
3) Connect HDBaseT receivers (e.g. HRX 1LP4K) to the HDBaseT Output ports with CAT5e or higher.
4) Connect HDMI displays (e.g. HDTV) to HDMI outputs of the Matrix or the receivers with HDMI cables
5) Connect speakers/earphones to AUDIO output ports
6) Connect the RS232 port of control device (e.g. a PC) to the RS232 port of either Matrix or far-end receivers. RS232 signal can be transmitted bi-directionally between Matrix and far-end receivers.
7) The Matrix can collect IR signal sent by the included IR remote via its built-in IR sensor or through external IR receiver connected to the IR IN/ IR OUT ALL/ IR ALL IN port. The IR signal can be transmitted bi-directionally between Matrix and far- end receivers.
8) Connect an AC 100V~240V power outlet and the Matrix with the AC power cord or the Transformer adaptor on the HMX 442LP4K, Select the correct Power Plug adaptor for your region
Note:
1) Output audio is selectable via RS232 command Audio/[X]:[Y]. It’s free to select whether analogue audio or HDMI audio to output. Default is HDMI audio. [Not applicable to HMX 442LP4K]
2) IR receivers connected to IR IN & IR ALL IN should be with
carrier. If not, send command %0900. or %0901.to activate
native carrier mode or force carrier mode in the IR matrix launched between Matrices and receivers.
User Manual
16/52
3.5 Connection with the HRX 1LP4K (310039) HDBaseT™ Receiver
The Triax series of Matrices are PoE compatible meaning that the matrices power up the HDBaseT™ receivers such as HRX
1LP4K. Connect a CAT5e patch lead to the RJ45 output port of the matrix to the pre-installed CAT cabling, at the receiver location there may a be RJ45 Socket or a direct cable. Plug the cable directly in to the receiver. If there is a socket insta lled you will need to connect a patch lead between the socket and the receiver, it is very important to use a high quality cable. Once all the connections have been made then plug in and turn on the matrix.
HMX 442LP4K
HMX 663LP4K
HMX 884LP4K