TRIAX 2010 IMPACT TEST SYSTEM
SPHERICAL HEAD FORM REFERENCE PROCEDURE
REVISION 1 June 17, 2016
GENERAL:
The Triax 2010 User Manual document details the Triax 2010 Verification Procedure in Appendix A. When using the spherical head form the verification procedure is still required, and a special fixture is provided with each spherical head form system to assist in establishing the head form height above the reference mat.
Photo 1 – Head form holding fixture
Photo 2 – Head form suspended from reference test fixture
Photo 3 – Connection of test fixture to tripod
USE OF FIXTURE:
This fixture consists of a quick release mechanism with a hook to allow the mechanism to be suspended from a suitable structure, such as a Triax system tripod. Also included are two wire rope lanyards connected by a metal ring.
WARNING: DO NOT USE THE TRIPOD TO SUPPORT THE SPHERICAL HEAD FORM DURING NORMAL TESTING. THE IMPACT OF THE TEST ARTICLE WILL CAUSE THE TRIPOD TO FALL CAUSING DAMAGE AND PERSONAL INJURY.