TRENDNET TFC-210MST, TFC-210S20D3 User Manual

Quick Installation Guide
TFC-1000
TFC-210 Series
TFC-2000 Series
Table of Contents
Table of Contents
Français ..........................................................................................
1. Avant de commencer ............................................................
2. Détails du produit ..............................................................
3. ..........................................................
Installation du matériel
LLCF Function ................................................................................
Technical Specifications .................................................................
....
1
1 2 3
9
11
13
Version 02.13.2007
1. Avant de commencer
Boîtier convertisseur fibre TFC-1000 pour convertisseurs des séries TFC-210 et TFC-2000:
Contenu de l'emballage
TFC-1000 Guide d’installation rapide Cordon d’alimentation
(courant alternatif) Support de montage et vis
Convertisseur fibre des séries TFC-210 ou TFC-2000 :
Contenu de l'emballage
Convertisseur fibre Guide d’installation rapide Alimentation AC (9V DC, 700mA)
1
Français
Convertisseur fibre 10/100Base-TX vers 100Base-FX
Nom du modèle
Multi/
Mono-Mode
Connecteur
Fibre
Distance
Longueur d’ondeBilan de liaison
TFC-210MST
TFC-210MSC
TFC-210S20D3
TFC-210S30
TFC-210S20D5
Multi-Mode
Mono-Mode Mono/ bidirectionnel
Mono-Mode
ST (Duplex)
SC (Duplex)
SC (Simplex)
2Km
30Km
20Km
TX:1310nm (1280nm ~ 1355nm) RX:1550nm (1530nm ~ 1570nm)
TX: (1530nm ~ 1570nm) RX:1310nm (1280nm ~ 1355nm)
1550nm
50/125um: 7,5dBm 62,5/125um: 11dBm
50/125um: 8,5dBm 62,5/125um: 8,5dBm
9/125um: 12dBm
1310nm (1270nm ~ 1380nm)
1310nm (1260nm ~ 1360nm)
Convertisseur fibre 00Base-T vers 1000Base-SX/LX
Multi/
Mono-Mode
Fiber
Connector
Distance
Longueur d’onde
Bilan de liaison
TFC-2000MSC
TFC-2000S20
TFC-2000S10D3
TFC-2000S50
TFC-2000S10D5
Multi-Mode
Mono-Mode Mono/ bidirectionnel
Mono-Mode
SC (Duplex)
SC (Simplex)
50Km
20Km
10Km
850nm (830nm ~ 860nm)
1310nm (1270nm ~ 1355nm)
1550nm (1520nm ~ 1580nm)
TX:1310nm (1280nm ~ 1355nm) RX:1550nm (1530nm ~ 1570nm)
TX: (1530nm ~ 1570nm) RX:1310nm (1280nm ~ 1355nm)
1550nm
9/125um:15dBm
9/125um:12dBm
9/125um:19dBm
Nom du modèle
550M
220M
50/125um:8,5dBm
62,5/125um:8,5dBm
2. Détails du produit
2
Français
3. Installation du matériel
Installation de 2 convertisseurs fibre autonomes
1. Branchez le câble fibre aux convertisseurs fibre.
2. Branchez un câble Ethernet RJ-45 ente le port Ethernet des convertisseurs de fibre et le port Ethernet de votre switch (e.g TE100-S24R ou TEG-S240TX).
3. Branchez l'adaptateur secteur à l'arrière du convertisseur fibre.
Remarque: – Câblage:
Câble optique multimode: TFC-210MST, TFC-210MSC, TFC-2000MSC
Câble optique monomode: TFC-210S30, TFC-210S50, TFC-2000S30, TFC-2000S50 Câble optique à simple brin por TFC-210S20D3/D5, TFC-210S10D3/D5
– Les câbles TX et RX doivent être inversés par rapport à la connexion
fibre opposée.
– Le TFC-210S20D3 doit être appareillé avec le TFC-210S20D5. Le
TFC-2000S10D3 doit être appareillé avec le TFC-2000S10D5.
– Les ports TX et FX ports du ne supportent pas l’auto
négociation. La connexion opposée cuivre et fibre doit être Gigabit.
Séries TFC-2000
3
Français
Installation d’un convertisseur fibre sur un switch
1. Branchez le câble fibre du convertisseur fibre à un switch fibre (p. ex. TE100-S810Fi)
2. Branchez un câble Ethernet RJ-45 ente le port Ethernet des convertisseurs de fibre et le port Ethernet de votre switch (e.g TE100-S24R ou TEG-S240TX).
3. Branchez l'adaptateur secteur à l'arrière du convertisseur fibre.
Remarque: Ceci ne s'appliqe pas aux TFC-210S20D3, TFC-210S20D5, TFC-2000S10D3 et TFC-2000S10D5.
4
Français
Installation d’un convertisseur fibre sur un PC
1. Branchez le câble fibre du convertisseur fibre à un adaptateur fibre (p. ex. TE100-PCIFX+).
2. Branchez un câble Ethernet RJ-45 entre le port Ethernet des convertisseurs de fibre et le port Ethernet de votre switch (e.g TE100-S24R ou TEG-S240TX).
3. Branchez l'adaptateur secteur à l'arrière du convertisseur fibre.
Remarque: Ceci ne s'appliqe pas aux TFC-210S20D3, TFC-210S20D5, TFC-2000S10D3 et TFC-2000S10D5.
5
Français
Installation d’un convertisseur fibre dans un boîtier
1. A l'aide d'un tourne vis, dévissez le couvercle de la baie désirée sur le boîtier et enlevez le couvercle. Conservez les vis et le couvercle qui vous serviront plus tard si vous devez refermer la baie.
2. Fixez le support de montage sur le côté du convertisseur fibre.
3. Insérez le convertisseur fibre dans un logement disponible. Installez le convertisseur fibre avec le port fibre près du bas du boîtier. Serrez ensuite les vis pour fixer le convertisseur fibre.
6
Français
Montage du rack
Le boîtier peut être installé dans un rack EIA standard de 19 pouces qui peut être placé dans une armoire de répartition avec les autres équipements.
1. Posez les supports de montage sur l'avant du boîtier (un de chaque côté), et fixez les avec les vis fournies.
2. Mettez soigneusemet le boîtier dnas le rack. Allignez les supports sur les trous des vis du rack, utilisez ensuite les vis fournies avec le rack pour fixer le boîtier
7
Français
Branchement de l’alimentation
1. Branchez le cordon d'alimentation fourni à l'arrière du boîtier.
2. Branchez le cordon d'alimentation à une prise de courant.
3. Mettez le switch sur ON pour alimenter le boîtier.
Commutateur DIP
Switch 1: ON: Mode Full Duplex TX
Séries TFC-210
Séries TFC-2000
*Après avoir changé les paramètres du switch DIP, éteignez et rallumez leconvertisseur fibre. **LLCF signifie Link Loss Carry Forward.
Switch 2: ON: Half Duplex FX OFF: Full Duplex FX Switch 3: ON: LLCF activé OFF: LLCF désactivé Switch 4: ON: Pure Mode OFF: Mode Switch
Switch 1: ON: LLCF TX activé
Switch 2: ON: LLCF fibre activé
OFF: Auto Négociation TX
OFF: LLCF TX (désactivé)
OFF: LLCF fibre (désactivé)
8
Français
LLCF Function
LLCF allows the network administrator to quickly troubleshoot the network connection based on the LEDs on the Fiber Converters. When the TX port link is down, the
converter will force the fiber port link to shutdown. When the fiber port link is down, the converter will force the TX port link to shutdown.
LLCF (Link Loss Carry Forward) Diagram
Cable 2
Cable 3
Cable 1
Copper Cable
Fiber Cable
Media
Converter 1
Media
Converter 2
Cable 4
Below are examples on how to read the LLCF Function Table: Example 1: If LLCF is enabled on Fiber Converter 1 and disable on Media Converter 2, when Cable 1 link is down, Fiber Converter 1's Copper and Fiber LED and Fiber Converter 2's Fiber LED will shut off. Fiber Converter 2's Copper LED remains on. Example 2: If LLCF is disabled on both Fiber Converters, when Cable 4 link is down, Fiber Converter 1's Copper and Fiber LED and Fiber Converter 2's Fiber LED remains on. Fiber Converter 2's Copper LED will shut off.
9
LLCF (Link Loss Carry Forward) Function Table
Media Converter 1 LLCF Enable
Media Converter 2 LLCF Enable
Media Converter 1 LLCF Enable
Media Converter 2 LLCF Disable
Media Converter 1 LLCF Disable
Media Converter 2 LLCF Enable
Media Converter 1 LLCF Disable
Media Converter 2 LLCF Disable
Cable 1 Link Down
Cable 2 Link Down
Cable 3 Link Down
Cable 4 Link Down
Cable 1 Link Down
Cable 2 Link Down
Cable 3 Link Down
Cable 4 Link Down
Cable 1 Link Down
Cable 2 Link Down
Cable 3 Link Down
Cable 4 Link Down
Cable 1 Link Down
Cable 2 Link Down
Cable 3 Link Down
Cable 4 Link Down
Media Converter 1
Copper
LED
OFF
OFF
OFF OFFOFFOFF
OFF OFF
OFF ON
OFF ON
ON ON OFF ON
OFF
ON OFF
OFF
ON
ON OFFON ON
Media Converter 2
Fiber
Copper
LED
LED
OFFOFF OFF
OFF
OFF OFF OFF
OFF OFFOFF
OFF ON
OFF OFF
ON ON ON
OFF OFF
ON ON ON
OFF OFF
ON
ON
Fiber
LED
OFFOFF
OFFOFFON OFF
OFFOFFON OFF
OFFOFFON
10
Specifications
TFC-210 series: IEEE 802.3 10Base-T
Standards:
LED Indicators:
Cable :
Dimensions:
Weight:
Power:
Temperature:
Humidity:
Certifications:
IEEE 802.3u 100Base-TX & 100Base-FX
TFC-2000 series: 1000Base-T, 1000Base-SX/LX, IEEE 802.3ab/ 802.3z
TFC-210 series: Power; 100Mbps, Full Duplex/ Collision, Link/Activity
TFC-2000 series: Power; 1000Mbps, Full Duplex/ Collision, Link/Activity
TFC-210 series:
10Base-T – UTP/STP Cat. 3, 4, 5 100Base-TX – UTP/STP Cat 5 100Base-FX – Multi-Mode –
62.5/125ìm or 50/125ìm Multi-Mode Fiber Optic Cable 100Base-FX – Single-Mode – 9/125ìm Single-Mode Fiber Optic Cable
TFC-2000 series:
1000Base-T – UTP/STP: Cat. 5e or Cat. 6 1000Base-SX– Multi-Mode –
50/125ìm or 62.5/125ìm Multi-Mode Fiber Optic Cable 1000Base-LX– Single-Mode – 9/125ìm Single-Mode Fiber Optic Cable
85mm × 125mm × 25mm (W × D × H)
Around 300 g (10 oz.)
9VDC, 700mA External Power Adapter
Operating: 0°C ~ 40°C (32°F ~ 104°F) Storage: -25°C ~ 70°C (-13°F ~ 158°F)
10 ~ 90%, non-condensing
CE, FCC
Fiber Converters
11
Capacity:
Material:
Power:
Power Consumption:
Cooling:
Dimensions:
Weight:
Temperature:
Humidity:
Certification:
Fiber Chassis
Ten bays for housing up to Ten media converters
Metal
AC 100~240V AC, 50/60Hz
90 Watts (Max)
One Fan
440 mm × 266mm × 133 mm (W × D × H) Standard 19” Rack Mount Size (3U)
6.4 kg (14.2 lb.)
Operating: 0°C ~ 40°C (32°F ~ 104°F) Storage: -25°C ~ 70°C (-13°F ~ 158°F)
10 ~ 90%, non-condensing
CE, FCC
12
Troubleshooting
After connecting the Fiber Converter, the LEDs do not turn on. What
Q1:
should I do?
First, check that the power outlet is receiving power. Second, make
A1:
sure the power adapter is firmly connected to the Fiber Converter and the power outlet. Third, make sure the Ethernet and the Fiber cables are connected.
All the LEDs are on, but I can't make a connection. What should I do?
Q2:
First, verify that you are using the proper fiber cable (e.g. multi-
A2:
mode fiber cable for multi-mode converters; single-mode fiber cables for single-mode converters). Second, verify that the TX and RX cables have been reversed on the opposite Fiber connection. Third, power down the Fiber Converters and the switches. Wait 15 seconds, then plug the switches and the Fiber Converters back in.
What is the maximum distance that is supported by the Fiber Converter?
Q3:
Please refer to Product Detail for distance information.
A3:
After connecting the Chassis to a power outlet, the LEDs do not turn on.
Q4:
First, check that the power outlet is receiving power. Second, make
A4:
sure the power cord is firmly connected to the chassis and the power outlet. Third, make sure the power switch is flipped to the ON position.
If you still encounter problems or have any questions please contact TRENDnet's Technical Support Department.
13
Limited Warranty
TRENDnet warrants its products against defects in material and workmanship, under normal use and service, for the following lengths of time from the date of purchase.
Fiber Chassis / Fiber Converters
- 5-Year Warranty
If a product does not operate as warranted above during the applicable warranty period, TRENDnet shall, at its option and expense, repair the defective product or deliver to customer an equivalent product to replace the defective item. All products that are replaced will become the property of TRENDnet. Replacement products may be new or reconditioned.
TRENDnet shall not be responsible for any software, firmware, information, or memory data of customer contained in, stored on, or integrated with any products returned to TRENDnet pursuant to any warranty.
There are no user serviceable parts inside the product. Do not remove or attempt to service the product through any unauthorized service center. This warranty is voided if (i) the product has been modified or repaired by any unauthorized service center, (ii) the product was subject to accident, abuse, or improper use (iii) the product was subject to conditions more severe than those specified in the manual.
Warranty service may be obtained by contacting TRENDnet office within the applicable warranty period for a Return Material Authorization (RMA) number, accompanied by a copy of the dated proof of the purchase. Products returned to TRENDnet must be pre-authorized by TRENDnet with RMA number marked on the outside of the package, and sent prepaid, insured and packaged appropriately for safe shipment.
14
WARRANTIES EXCLUSIVE: IF THE TRENDNET PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, THE CUSTOMER’S SOLE REMEDY SHALL BE, AT TRENDNET’S OPTION, REPAIR OR REPLACEMENT. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. TRENDNET NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE OR USE OF TRENDNET’S PRODUCTS.
TRENDNET SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER’S OR ANY THIRD PERSON’S MISUSE, NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO REPAIR OR MODIFY, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE, LIGHTNING, OR OTHER HAZARD.
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW TRENDNET ALSO EXCLUDES FOR ITSELF AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE), FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATE, OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE, PERFORMANCE, FAILURE, OR INTERRUPTION OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT TRENDNET’S OPTION. THIS DISCLAIMER OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF ITS ESSENTIAL PURPOSE.
Governing Law: This Limited Warranty shall be governed by the laws of the state of California.
Note: AC/DC Power Adapter, Cooling Fan, Cables and Power Supply carry a 1-Year Warranty
15
Certifications
This equipment has been tested and found to comply with FCC and CE Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received. Including interference that may cause undesired operation.
Waste electrical and electronic products must not be disposed of with household waste. Please recycle where facilities exist. Check with you Local Authority or Retailer for recycling advice.
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.
ADVERTENCIA En todos nuestros equipos se mencionan claramente las caracteristicas del adaptador de alimentacón necesario para su funcionamiento. El uso de un adaptador distinto al mencionado puede producir daños fisicos y/o daños al equipo conectado. El adaptador de alimentación debe operar con voltaje y frecuencia de la energia electrica domiciliaria existente en el pais o zona de instalación.
TRENDnet Technical Support
Toll Free Telephone: 1(866) 845-3673
.
US Canada
24/7 Tech Support
Europe (Germany France Italy Spain Switzerland UK)
Toll Free Telephone: +00800 60 76 76 67
English/Espanol - 24/7 Francais/Deutsch - 11am-8pm, Monday - Friday MET
Telephone: +(31) (0) 20 504 05 35
Worldwide
English/Espanol - 24/7 Francais/Deutsch - 11am-8pm, Monday - Friday MET
. . . . .
Product Warranty Registration
Please take a moment to register your product online.
Go to TRENDnet’s website at http://www.trendnet.com
20675 Manhattan Place Torrance, CA 90501
USA
Copyright ©2007. All Rights Reserved. TRENDnet.
Loading...