This chapter provides network managers and system administrators with information
about how to configure the Media Converter Chassis system.
The reader of this document should be knowledgeable about network devices, device
configuration, network management, and Internet browsers. The user is assumed to be a
network administrator or manager with an understanding of network operations.
The Media Converter Chassis system
The chassis’s first slot is for the management module as illustration on figure 1.
Figure 1. Slide in the management module in the first slot of the chassis system.
Installing the Management Module
Before Configure the chassis system, you must do the following:
??Install the management module into the chassis. (Figure 1)
??Connect the module to the network.
??Boot up for SNMP management on Web browser or emulation terminal
program.
Configure through Web browser
The Media Converter chassis system is accessible using a Web browser (IE explorer,
Netscape Communications, etc.) to open up the chassis monitoring system. The default
IP Address for the chassis system is “192.168.1.1”, and the default Login name and
password is both “root”.
Configuration via Serial Port
The Media Converter chassis system can be accessible using a terminal or terminal
emulator attached to the RS232 serial port on the Switch too.
NOTE: (1) The serial port cable is attached directly with the device.
(2) It needs to upgrade the Terminal Emulator due to key malfunction.
1. Locate correct DB9 serial port cable with female DB9 connector.
2. Attach the DB9 serial port female cable connector to the male DB9 serial port
connector on the chassis system.
3. Attach the other end of the DB9 serial port cable to a remote workstation.
4. By default, the Switch uses the following serial port parameter values:
Bits per second 57600
Stop bits 1
Data bits 8
Parity NONE
Flow Control NONE
LINK/ACT
CPU WORK
CPU FAIL
LINK
5. The default Login name and password is both “root”.
Support SNMP Management
The Media Converter Management Module supports SNMP management.
LED Indicators
The LED indicators of the Switch include Power, ALERT, HTTP, ICQ, SMTP, SPEED,
LINK/ACT and FDX/COL. The following shows the LED indicat ors for the Switch
along with an explanation of each indicator.
10/100 Fast Ethernet
1 2
POWER ON
POWER FAIL
FAN FAIL
MGM
CONSOLE
DATA TRANSFER
ERROR DATA
DATA TRANSFER
Power On: Lights green when the power is inserted.
Power Fail: Lights Amber when the power is inserted and it is fail.
Fan Fail: Lights Amber when the fan is fail.
MGM: Blinks green when the device CPU is working and lights amber
when the CPU works fail.
Console: Blinks green when the data is transmitting through console port
and blinks amber when transmitting the wrong data.
Link/Act: Lights green when link to networking Ethernet and blinks green
for activity.
Management Setting Through Web Browser
1 Main Menu
Figure (1) Main Menu
1-1 System Function
There are four items in System Function menu, “Software Reboot, Factory Reset, Image
Update and Configuration Update. (Figure 2)
1-2 Configuration
There are three items in Configuration menu, “General Configuration, System
Configuration and SNMP Configuration. (Figure 2)
Figure (2) Configuration
1-1-1 Software Reboot
To reboot for the software setting.
1-1-2 Factory Reset
This function is to set the device back to the default setting in case of the messy setting.
1-1-3 Image Update
Figure (3)
The section is to set the TFTP Server IP Address first, and the default address was set to
“192.168.1.2”. The Image File can be updated by uploading the image file from the
TFTP server. (Figure 3)
Note: The content of the image file will write the whole firmware of the management module, please
be sure that the image file is correct.
1-1-4 Configuration Update
Loading...
+ 11 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.