TREND TB, TS, K Installation Instructions Manual

Page 1
TB/TS/K Thermistor Room Temperature Sensors Installation Instructions TG200607 Issue 1/D 29/03/07
1
Installation Instructions
TB/TS/K
Thermistor Room Temperature Sensors
Important: Retain these instructions
Dimensions
1
Requirements
2
b
a
UNPACKING
-
+
85 mm (3.35”)
26 mm (1.02”)
85 (3.35”)
4 mm (0.16”)
- +
- +
c
> 50 cm (20”)
1.5 m (5 ft)
e
d
f
g
TB/TS/K Installation Instructions TG200607
Page 2
TB/TS/K Installation Instructions
TB/TS/K Thermistor Room Temperature Sensors Installation Instructions TG200607 Issue 1/D 29/03/07
2
INSTALLATION (continued)
Requirements (continued)
2
Mount backplate
4
Remove cutout(s)
5
Route cables
6
i
j
l
H O
2
- +
-10 °C (14 °F)
+50 °C (122 °F)
0 %RH
90 %RH
or wall
BESA box
35 mm (1.38”)
60 mm (2.36”)
wall box fascia
h
Remove backplate
3
as required
a
b
0 °C (32 °F)
+40 °C measurment (104 °F)
35 mm (1.38”)
35 mm (1.38”)
35 mm (1.38”)
FR
ABS
l
- +
- +
- +
- +
Page 3
TB/TS/K Thermistor Room Temperature Sensors Installation Instructions TG200607 Issue 1/D 29/03/07
3
Installation Instructions TB/TS/K INSTALLATION (continued)
Wire to controller
7
if IQ
1 2 3
TB/TS
2 1 2 2
1
C O M
I Q L 1 2 , 1 4
2
1
1
2
3
TB/TS
/K
C O M
2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8
C O M
1
2 3 4
5
C
I Q L 1 3 + , 1 5 + , 1 6
0 V T e m p e r a t u r e
K n o b
1 2
3
I N
I N
C O M ( 0 V )
S E N S O R
I Q 2
T B / T S
/ K
C O M ( 0 V )
if IQL
TB/TS
C O M
910
1
I Q L 1 0 / 2 4 V A C
21
TB/TS
1 5 1 6
1
C O M
I Q L 1 0 / 2 3 0
2
1
TB/TS
9 1 011 1 1 2
1 3
3
C O M
C
2
I Q L 1 1 + / 2 4 V A C
321
/K
TB/TS
C O M
1 5 1 6 1 7 1 8 1 9
1
2 3
C
I Q L 1 1 + / 2 3 0
1
2
3
/K
NOITPOSLANIMRETTCENNOC
ST/BT2,1
K/ST/BT3,2,1
LQISNOITPO
41,21,01LQI
ST/BT
71,61,+51,+31,+11LQI
K/ST/BT,ST/BT
Note that screened cable is not required for sensor wiring to IQLs. If screened cable is used, the screen must be terminated at the controller to its supply cable earth.
Terminal size 0.5 to 2.5 mm
2
(14 to 20 AWG)
1
2
3
TB/TS
/K
C O M
2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8
1
2 3 4
5
C
0 V
A I
1 0 V
I Q L 1 7
0 V T e m p e r a t u r e
K n o b
1 2
3
N ( i n )
S E N S O R
I Q 3
T B / T S
/ K
0 ( 0 V )
+ ( + 2 4 V )
N ( i n )
0 ( 0 V )
+ ( + 2 4 V )
N
N + 1
analogue inputs linked for thermistor (T)
analogue inputs linked for thermistor (T)
Page 4
TB/TS/K Installation Instructions
TB/TS/K Thermistor Room Temperature Sensors Installation Instructions TG200607 Issue 1/D 29/03/07
4
Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37,Switzerland by its Authorized Representative, Trend Control Systems Limited.
Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes.
Trend Control Systems Limited
P.O. Box 34, Horsham, West Sussex, RH12 2YF, UK. Tel:+44 (0)1403 21888 Fax:+44 (0)1403 241608 www.trend-controls.com
Trend Control Systems USA
6670 185th Avenue NE, Redmond, Washington 98052, USA. Tel: (425)897-3900, Fax: (425)869-8445 www.trend-controls.com
WEEE Directive :
At the end of their useful life the packaging and product should be disposed of by a suitable recycling
centre. Do not dispose of with normal household waste. Do not burn.
- +
Y
epyttupnI
)smhoK(3
E
tnenopxE
1
U
reppU
2.3
L
rewoL
2.3-
P
stnioP
4
xxIxO
1
59.1.3-
2
50.13-
3
59.83+
4
50.311.3+
Test system
10
If IQ
I Q
/K
Δ T
Δ SP
Set up IQ Sensor types
9
Thermistor
(0 to +40 °C)
Knob
(trim -3 to +3)
IQL Strategy Installation Instructions
If IQL
It is recommended to use SET (software tool) for the setting of sensor type modules. For all IQ2 series controllers with firmware version 2.1 or greater, or IQ3 series controllers, select the appropriate SET Unique Sensor Reference from the following:
Knob: Knob TB 3 deg trim (guaranteed ±3 trim)
alternatively: Knob T 3 deg trim (±3 ±20% linear)
Thermistor: Thermistor TBTS (°C)
Thermistor TBTS F (°F) (change the values of U and L to those in the following table)
If not using SET, use the following tables for all IQ2 series controllers of firmware version 2.1 or greater or IQ3 controllers, and set mode to 5 (characterise); for all other IQ controllers see Sensor Scaling Reference Card TB100521A.
If IQ controller
INSTALLATION (continued)
stinU
C°F°
Y
epyttupnI
)stlovrotsimreht(1
E
tnenopxE
3
U
reppU
05221
L
rewoL
5-32
P
stnioP
6
xxI)C°(xO)F°(xO
1
146.205221
2
74.304401
3
64.40368
4
366.60105
5
866.7023
6
201.85-32
DISPOSAL
Assemble unit
8
‘click’
Loading...