TREND DAR/200 User Manual

Page 1
DIGITAL ANGLE RULE REF. DAR/200
Thank you for purchasing this Trend product which should give lasting performance if used in accordance with these instructions.
INTENDED USE
This accessory is intended to be used to measure the angle and length of a component.
SAFETY
Read and understand the instruction sheet carefully before using. This is a sensitive precision tool. Do not disassemble or drop it. Please note the sharp edges, avoid scratching. Store out of reach of children. Do not use as a toy or as a weapon. PLEASE KEEP THESE INSTRUCTIONS IN A SAFE PLACE.
7
32NDS
MM
MM 10 20 30 40 50 60 70 80 90 100 110 120 130 140
6543
3214567
2
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
35mm
Hanging holes
Locking knob
Battery container
Ruler
LCD
200mm
2.5mm
8mm
200mm
20mm
130 140
2
ZERO ON OFF
Tighten
Loosen
130 140
2
ZERO ON OFF
Push
Negative pole uppermost
130 140
2
ZERO ON OFF
Pull
130 140
2
ZERO ON OFF
Push
ZERO ON OFF
ON/OFF button
ZERO button
1. Short press ON/OFF to turn on,
close up both rulers and place on the flat surface, make sure both ruler’s edges touch the surface, press ZERO button to set zero.
PP C/DAR/200 v1.0
MM
3 2 14567
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
7
32NDS
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
7”
400mm
Metric Scale (standard rule)
Imperial Scale
7”
MM
3 2 14567
MM10 220 230 240 250 260 270 280 290300 310 320 330 340 350 360 370 380 390
7
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
7
MM
MM 10 20 30 40 50 60 70 80 90 100 110 120 130 140
6543
3214567
2
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
7
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
7
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
MM
3 2 1
4567
MM10 220 230 240 250260 270
280 290
300
310320 330 340
350
360370380
390
7
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
MM
3 2 1
4567
MM10 220 230 240 250260 270
280 290
300
310320 330 340
350
360370380
390
2. Rotate the rule to measure the angle.
Li-lon
Battery Fitting and Replacement
n
To fit or replace battery push the tab on the bottom of the LCD. The edge of the battery container will appear on the opposite side of the LCD.
n Pull the battery container out.
n Remove the old battery. Insert the new
battery type CR2032 3v.
n Ensure the negative pole of the battery
is uppermost. The positive pole is on the underside of the battery.
n Push the battery container back in.
Denotes risk of personal injury, loss of life or damage to the tool in case of
nonobservance of the instructions. The attention of UK users is drawn to The Provision and Use of Work Equipment Regulations 1998, and any subsequent amendments. Users should also read the HSE/HSC Safe Use of Woodworking Machinery Approved Code of Practice and Guidance Document and any amendments. Users must be competent in woodworking equipment before using our products.
n Rotate clockwise to tighten the moving rule.
n Rotate anti-clockwise to loosen the moving rule.
TROUBLE SHOOTING
Problem Possible Cause Solution
No display or Lower voltage, no battery or Reinstall battery or ambiguous reading. incorrect installation of battery. replace battery.
Erratic display. Misfunction caused Press zero to reset by high vibration or heavy zero. swinging of rule.
Number skip or Internal error. Remove battery, wait one frozen display. minute and replace.
MAINTENANCE
The rule has been designed to operate for a long period of time with the minimum of maintenance. Continual satisfactory operation depends upon proper tool care and regular cleaning.
Cleaning
n Clean with mild liquid soap and damp cloth. Dry with soft cloth. Never immerse in water. Rule requires no additional lubrication.
Storage
n Return to packaging after use if it is not to be used for a long time. Store rule in a dry and shady place. Never leave it outside or in a wet environment. Before storing, it is recommended to wipe surfaces with an anti-rust oil.
GUARANTEE
All Trend products are guaranteed against any defects in either workmanship or material, except products that have been damaged due to improper use or maintenance.
ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing as waste. Packaging should be sorted for environmental-friendly recycling. The product, at the end of it’s life, should be sorted for environmental-friendly recycling.
Batteries and the Environment
This unit uses Lithium Ion (Li-Ion) batteries. When battery pack needs replacing, we recommend the following: Discharge the energy from the batteries by running them down completely and then remove from the tool.
Li-Ion cells are recyclable so do not throw them away with household waste. They may end up in an incinerator or landfill, which must be avoided.
Instead, take the batteries to a Trend Service Agent, your local Trend Stockist or a local recycling station. If necessary contact your local municipality for disposal information. The collected batteries will be disposed of properly and/or used for recycling purposes.
DESCRIPTION OF PARTS
Battery Care
WARNING! Insert battery correctly. Keep batteries away from children. Do not swallow, open, recharge, or expose to water, fire or high temperature: may explode, leak and cause damage.
CONFORMITY DECLARATION
This product conforms with EMC Directive 2004/108/EC.
TECHNICAL DATA
Measuring Range: 000.0° - 999.9° (more than 999.9° will show incorrect display) Working Temperature: 0°C to +50°C Working Humidity: 85% RH Working Current: 50 uA Resolution: 0.1° Accuracy: 0. Battery: CR2032 3V Lithium Battery Weight: 162g
Measuring Obtuse Angles
2. Rotate the rule to measure the angle.
1. Short press ON/OFF to turn on,
open up both rulers and place on the flat surface, make sure both ruler’s edges touch the surface, press ZERO button to set zero.
135º
45º
ON/OFF button: Short press ON/OFF to turn on, or alternatively move the scale to turn on the device when at off LCD status. Short press ON/OFF to turn off the LCD. Long press ON/OFF for more than 3 seconds to
shut off the whole system. Automatically turns off in 6 minutes.
ZERO button: Press ZERO to set zero at any point when turned on.
OPERATION
Measuring Acute Angles
Page 2
7
32NDS
MM 10 20 30 40 50 60 70 80 90 100 110 120 130 140
6543
3214567
2
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
Locking knob
Battery container
LCD
200mm
2.5mm
8mm
200mm
20mm
130 140
2
ZERO ON OFF
Tighten
Loosen
130 140
2
ZERO ON OFF
Push
Negative pole uppermost
130 140
2
ZERO ON OFF
Pull
130 140
2
ZERO ON OFF
Push
ZERO ON OFF
ON/OFF button
ZERO button
PP C/DAR/200 v1.0
MM
3 2 14567
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
MM10
400mm
7”
MM
3 2 14567
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
7
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
7
MM
MM 10 20 30 40 50 60 70 80 90 100 110 120 130 140
6543
3214567
2
MM10 220 230 240 250 260 270 280 290 300 310 320 330 340 350 360 370 380 390
MM10
7
MM
10 20 30 40 50 60 70 80 90 100 110 120 130 140
65432
MM10
MM
3 2 1
4567
MM10 220 230 240 250260 270
280 290
300
310320 330 340
350
360370380
390
MM10
MM
3 2 1
4567
280 290
300
310320 330 340
350
360370380
390
2. Rotate the rule to measure the angle.
Li-lon
Battery Fitting and Replacement
n
To fit or replace battery push the tab on the bottom of the LCD. The edge of the battery container will appear on the opposite side of the LCD.
n Pull the battery container out.
n Remove the old battery. Insert the new
battery type CR2032 3v.
n Ensure the negative pole of the battery
is uppermost. The positive pole is on the underside of the battery.
n Push the battery container back in.
Denotes risk of personal injury, loss of life or damage to the tool in case of
nonobservance of the instructions. The attention of UK users is drawn to The Provision and Use of Work Equipment Regulations 1998, and any subsequent amendments. Users should also read the HSE/HSC Safe Use of Woodworking Machinery Approved Code of Practice and Guidance Document and any amendments. Users must be competent in woodworking equipment before using our products.
TROUBLE SHOOTING
Problem Possible Cause Solution
No display or Lower voltage, no battery or Reinstall battery or ambiguous reading. incorrect installation of battery. replace battery.
Erratic display. Misfunction caused Press zero to reset by high vibration or heavy zero. swinging of rule.
Number skip or Internal error. Remove battery, wait one frozen display. minute and replace.
MAINTENANCE
The rule has been designed to operate for a long period of time with the minimum of maintenance. Continual satisfactory operation depends upon proper tool care and regular cleaning.
Cleaning
n Clean with mild liquid soap and damp cloth. Dry with soft cloth. Never immerse in water. Rule requires no additional lubrication.
Storage
n Return to packaging after use if it is not to be used for a long time. Store rule in a dry and shady place. Never leave it outside or in a wet environment. Before storing, it is recommended to wipe surfaces with an anti-rust oil.
GUARANTEE
All Trend products are guaranteed against any defects in either workmanship or material, except products that have been damaged due to improper use or maintenance.
ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing as waste. Packaging should be sorted for environmental-friendly recycling. The product, at the end of it’s life, should be sorted for environmental-friendly recycling.
Batteries and the Environment
This unit uses Lithium Ion (Li-Ion) batteries. When battery pack needs replacing, we recommend the following: Discharge the energy from the batteries by running them down completely and then remove from the tool.
Li-Ion cells are recyclable so do not throw them away with household waste. They may end up in an incinerator or landfill, which must be avoided.
Instead, take the batteries to a Trend Service Agent, your local Trend Stockist or a local recycling station. If necessary contact your local municipality for disposal information. The collected batteries will be disposed of properly and/or used for recycling purposes.
Battery Care
WARNING! Insert battery correctly. Keep batteries away from children. Do not swallow, open, recharge, or expose to water, fire or high temperature: may explode, leak and cause damage.
CONFORMITY DECLARATION
This product conforms with EMC Directive 2004/108/EC.
TECHNICAL DATA
Measuring Range: 000.0° - 999.9° (more than 999.9° will show incorrect display) Working Temperature: 0°C to +50°C Working Humidity: 85% RH Working Current: 50 uA Resolution: 0.1° Accuracy: 0.3° Battery: CR2032 3V Lithium Battery Weight: 162g
1. Short press ON/OFF to turn on,
open up both rulers and place on the flat surface, make sure both ruler’s edges touch the surface, press ZERO button to set zero.
45º
shut off the whole system. Automatically turns off in 6 minutes.
ZERO button: Press ZERO to set zero at any point when turned on.
Measuring Acute Angles
Page 3
Calculates angles quickly & accurately.
n Digital display for
angles.
n Stainless steel rule
with metric/imperial scale.
n Measuring range from
000.0° to 360.0° with an accuracy of 0.3°.
n Rule locking function. n Ideal for woodworking,
construction & machining.
TM
DAR/200
DAR/200
TM
Trend Machinery & Cutting Tools Ltd.
Tel: 0044(0)1923 249911 enquiries@trendm.co.uk www.trend-uk.com
Trend Routing Technology Inc.
Tel: 0044(0)1923 249911 enquiries@trend-usa.com www.trend-usa.com
GB
USA
Our policy of continuous improvements mean that specifications may change without notice. Trend Machinery & Cutting Tools Ltd. cannot be held liable for any material rendered unusable, or for any form of consequential loss.
© Copyright Trend 2010. E&OE. ® All trademarks acknowledged.
Li-lon
External Angle Finder
Internal Angle Finder
Angle Finder
Rule
ANGLE
RULE
400mm
(2x200mm)
DIGITAL
n Easy operation
with two press buttons.
n Auto-shut off in 6
minutes.
n Includes CR2032
3v Lithium battery.
DIGITAL ANGLE RULE
400mm
(2x200mm)
Loading...