Trek PZD350AMS User Manual

Trek Model PZD350A M/S
Piezo Driver/Power Amplifier
Trek’s PZD350A M/S Piezo Driver/Amplifier system provides
precise voltage control and delivers twice the current of our standard PZD350A. This high-voltage DC-powered amplifier offers voltages that can will be factory set to customer-specified ranges. It features an all-solid state design, impressive slew rates and superior bandwidth capabilities.
Other features include a four-quadrant active output stage that sinks or sources current into reactive or resistive loads throughout the output voltage range, precision voltage and current monitors, remote access and dynamic adjustment. The input is configured is inverting but an inverting amplifier configuration is available.
Key Specifications
! Output Voltage Range Bipolar:
Unipolar (Positive): 0 to +700 V or peak AC and Unipolar (Negative): 0 to -700 V or peak AC
! Output Current Range Bipolar:
Unipolar: 0 to ±200 mA
! Slew Rate Bipolar: Greater than 500 V/
Unipolar: Greater than 400 V µs
Large Signal Bandwidth Bipolar: DC to greater than 250 kHz (-3 dB)
!
Unipolar: DC to greater than 200 kHz (-3 dB)
DC Voltage Gain: 0 to 150 V/V, adjustable using a front panel potentiometer
!
0 to ±350 V DC or peak AC
0 to ±400 mA
µs
/
Typical Applications Include
! Piezoelectric driving/control !
Laser modulation
!
MEMS
!
Semiconductor research
!
Piezoelectric vibration damping
Features and Benefits
Four-quadrant output for driving capacitive loads
!
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
!
All solid-state design for maintenance-free operation
!
DC-stable for programmable supply applications
!
Low output noise for ultra-accurate outputs
!
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
Features (cont.)
Input Configuration
The input is configured as a noninverting amplifier. An inverting amplifier is also available
Limit Indicator
An amber indicator warns when the unit fails to produce the required HV output.
Automatic Power Limit
Automatically limits the internal power dissipation to protect the PZD350A M/S from overheating.
Mechanical
Dimensions
110 mm H x 432 mm x W 445 mm D (4.3” H x 17” W x 17.5” D)
Weight
10 kg (22 lb)
HV Connector
SHV High Voltage Connector
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges: 90 to 127 V AC or 180 to 250 V AC, either at 48 to 63 Hz
AC Line Receptacle
Standard 3-prong with integral fuse holder
Power Consumption
90 VA, single channel 175 VA, dual channel
HV Cable
2 m, 66 pF per foot
Supplied Accessories
Operator’s Manual
PN: 23434
HV Output Cable Assembly
PN: 43874R cable and SHV mating connector Line Cord, Fuses
Selected per geographic destination
Optional Accessories
19-in Rack Mount Kit
Model 604RA (with EIA hole spacing)
19-in Rack Mount Kit
Model 604RAJ (with JIS hole spacing)
Ordering Information
90 to 127 V AC 180 to 250 V AC
Model PZD350A-L M/S CE Model PZD350A-H M/S CE
Notes
The Model PZD350A M/S comes from the factory with settings for an output voltage of ±350 V DC or peak AC, a voltage gain ratio of 100 V/V, with a noninverting input. Please specify voltage range (±350 V, +700 V, or -700 V) and input configuration (inverting or noninverting) when ordering.
Also available is the Model PZD350A with half the current capability of the PZD350A M/S.
Model PZD350A M/S Specifications
Performance
Output Voltage Range
Bipolar: 0 to ±350 V DC or peak AC
Output Voltage Range
Unipolar Positive: 0 to +700 V DC or peak AC
Output Voltage Range
Unipolar Negative: 0 to -700 V DC or peak AC
Output Current Range
Bipolar: 0 to ±400 mA
Output Current Range
Unipolar: 0 to ±200 mA Input Voltage Range
0 to ±10 V DC or peak AC
Input Impedance
90 kW, nominal (non-inverting) 1 MW nominal, (inverting)
DC Voltage Gain
0 to 150 V/V, adjustable using the front panel potentiometer
DC Voltage Gain Accuracy
Better than 0.1% for factory set gain of 100 V/V Offset Voltage
Less than ±500 mV
Output Noise (all ranges)*
Less than 100 mV rms to 20 kHz for 100 pF load. Less than 150 mV rms to 20 kHz with no load.
Slew Rate (10% to 90%, typical)
Bipolar: Greater than 500 V/µs Unipolar: Greater than 400 V/µs
Large Signal Bandwidth (-3 dB)
Bipolar: DC to greater than 250 kHz Unipolar: DC to greater than 200 kHz
Small Signal Bandwidth (-3dB)
Bipolar: DC to greater than 350 kHz Unipolar: DC to greater than 250 kHz
Settling Time
Less than 30 µs when critically damped
Stability
With a factory set gain of 100 V/V
Drift with Time
Less than 50 ppm/hr, noncumulative
Drift with Temp
Less than 100 ppm/°C
Voltage Monitor
Ratio
1 V/100 V ±0.1% of full scale
Current Monitor
Ratio
0.025 V/mA, ±1% of full scale
Features
Digital Enable
BNC connection for TTL compatible signal to turn ON/OFF the HV output for each channel.
Gain Control
The gain of the Model PZD350A M/S is adjustable from 0 to 300 V/V
Dynamics Adjustment
A graduated 1-turn front panel potentiometer is used to optimize the AC response of the
for various load configurations.
output
signal
*Measured using the true rms feature of the HP Model 34401A digital multimeter)
Measurement and Power Solutions
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1239/DEC
TM
www.trekinc.com
Loading...