Trek PD07016 User Manual

Trek Model PD07016
High-Voltage Power Amplifier
The Model PD07016 is a DC-stable, high-voltage power amplifier featuring an all solid-state design for high slew rate, wide bandwidth, and low-noise operation. It is configured as noninverting with a fixed gain of 1000 V/V and is protected against over-voltage and over-correct conditions that may be generated by active loads or
by output short circuits to ground. Precision voltage and current monitors provide low-voltage representations of the high-voltage output and load current for monitoring purposes or for use as feedback signals in a closed-loop system.
The 4-quadrant, active output stage sinks or sources current to reactive or resistive loads throughout the output voltage range. This is essential to achieve the accurate output response and high slew rates demanded by reactive loads.
Key Specifications
! Output Voltage Range: ! Output Current Range: ±300 mA
! Slew Rate: Greater than 1000 V/
Large Signal Bandwidth DC to greater than 10 kHz
!
(2% distortion): DC Voltage Gain: 1000 V/V
!
0 to ±10 kV DC or peak AC 0 to ±60 mA DC,0 to peak capability for 20 µs
µs
Typical Applications Include
! Automated or computer controlled systems ! Providing feedback signals in closed-loop systems
Features and Benefits
! Four-quadrant output for driving capacitive loads !
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
!
All solid-state design for maintenance free operation
!
DC-stable for programmable supply applications Inverting and differential options available
! !
Low output noise for ultra-accurate outputs NIST-traceable Certificate of Calibration provided with each unit
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
Features (cont.)
High-Voltage On/Off
Local
Individual push-button switches
Remote
TTL compatible input. TTL high (or open) turns off high-voltage output. TTL low turns on high­voltage output.
Current Limit/Trip
Switch selectable for limit or trip. Graduated 1­turn panel potentiometer is used to adjust limit or trip level from 0 to ±60 mA.
Out of Regulation Status Indicator and Connector
Illuminates and TTL low is provided when unit fails to produce required HV output such as during current limit.
Limit/Trip Status Indicator and Connector
Illuminates and a TTL low is provided when HV is disabled or when amplifier is out of regulation for more than 500 ms
Mechanical
Dimensions
91.4 cm H x 43 cm W x 87 cm D (36” H x 17” W x 34” D) Depth dimension includes handles and spacing for air flow.
Weight
73 kg (160 lb) approximate
HV Connector
Caton high-voltage Connector
BNC Connectors
Amplifier Input, Voltage Monitor, Current Monitor, Remote High Voltage ON/OFF, Out of Regulation Status, Fault/Trip Status
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 75%, noncondensing
Altitude
To 1524 meters (5000 ft.)
Electrical
Line Voltage
Factory set for one of two ranges: 104 to 127 V AC or 180 to 250 V AC at 48 to 63 Hz (specify when ordering)
Power Consumption
1800 VA, maximum
AC Line Receptacle
Standard 3-prong with integral fuse holder
Supplied Accessories
Operators Manual
PN: 23383
Shorting BNC Cap
PN: B3060
HV Output Cable
PN: 43466
Line Cord, Fuses
Selected per geographic destination
Optional Accessories
Locking Wheel Kit
CN: 1K042
Model PD07016 Specifications
Performance
Output Voltage Range
0 to ±10 kV DC or peak AC
Output Current Range
0 to ±60 mA DC, 0 to 300 mA peak capability for 20 µs
Input Voltage Range
0 to ±10 V DC or peak AC
Input Impedance
25 kW nominal (inverting/differential option 50 kW, nominal)
DC Voltage Gain
1000 V/V
DC Voltage Gain Accuracy
Better than 0.1% of full scale Offset Voltage
Less than ±4 V
Output Noise
Less than 5 V rms*
Slew Rate (10% to 90%, typical)
Greater than 1000 V/µs
Small Signal Bandwidth (-3dB)
DC to greater than 20 kHz
Large Signal Bandwidth (2% distortion)
DC to greater than 10 kHz
Stability
Drift with Time
Less than 50 ppm/hr, noncumulative
Drift with
Temperature-
Less than 100 ppm/°C
Voltage Monitor
Ratio
1 V / 1000 V
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±5 mV
Output Noise
Less than 20 mV rms*
Output Impedance
47 W
Current Monitor
Ratio
30 V/mA
DC Accuracy
Better than 2% of full scale
Offset Voltage
Less than ±10 mV
Output Noise
Less than 30 mV rms*
Bandwidth (-3dB)
DC to greater than 5 kHz
Output Impedance
47 W
Features
Settling Time (to 1%)
Less than 200 µs for a 0 to 10 kV step
Dynamic Adjustment
Graduated 1-turn panel potentiometer is used to optimize the AC response for various load parameters.
*Measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1236/DEC
Measurement and Power Solutions
TM