Trek Model PD06087
High-Voltage Power Amplifier
The Model PD06087is a DC-stable, high-voltage power
amplifier used in industrial and research applications. It
features an all-solid-state design for high slew rate, wide
bandwidth and low-noise operation. The four-quadrant, active
output stage sinks or sources current into reactive or resistive
loads throughout the output voltage range. This type of output is
essential to achieve an accurate output response and high
slew rate demanded by a variety of loads such as highly
capacitive or reactive loads. It is configured as a non-inverting
amplifier.
Key Specifications
! Output Voltage Range:
! Output Current Range:
! Slew Rate: Greater than 500 V/
!
Large Signal Bandwidth (1% distortion): DC to greater than 15 kHz
!
DC Voltage Gain: Fixed at 1000 V/V
0 to ±5 kV DC or peak AC
0 to ±20 mA or peak AC
µs
Typical Applications Include
! Electrophoresis
Electrophotography
!
!
Electrostatic deflection
!
Electro-optic modulation
!
AC or DC biasing
Features and Benefits
!
Four-quadrant output for driving capacitive loads
!
Closed loop system for high accuracy
!
Short-circuit protected for equipment protection
!
All solid-state design for maintenance free operation
DC-stable for programmable supply applications
!
Low output noise for ultra-accurate outputs
!
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
(fax) • www.trekinc.com • sales@trekinc.com 716-438-7555 • 716-201-1804
Graduated 1-turn panel potentiometer is used
to optimize the AC response for various load
parameters
Switch selectable for either limit or trip.
Graduated 1-turn panel potentiometer is used
to adjust limit or trip level from 0 to ±20 mA
Illuminates and a TTL low is provided when unit
fails to produce required HV output for 500 ms
or more such as during current limit or short
circuit conditions
Illuminates and a TTL low is provided when the
high-voltage output is disabled due to the
output current exceeding the current trip level,
the detection of a high-voltage supply fault or
the removal of the top cover
190 mm H x 432 mm W 417 mm D
(7.5” H x 17” W x 16.4” D)
Alden high-voltage connector
Amplifier Input, Voltage Monitor, Current Monitor,
Remote High Voltage ON/OFF, Out of Regulation
Status, Fault/Trip Status
0°C to 40°C (32°F to 104°F)
To 2000 meters (6561.68 ft.)
Factory Set for one of two ranges:
104 to 127 V AC or 180 to 250 V AC,
either at 48 to 63 Hz
Standard AC line connector with integral fuse
holder
PN: N5002; s
destination
elected per geographic
High-voltage output
cable
PN: 43421 (5 meter)
High-voltage output
High-voltage output
cable
PN: 43423 (20 meter)
19-in Rack Mount Kit
Model 608RA (EIA hole spacing)
Model 608RAJ (JIS hole spacing)
Model PD06087 Specifications
0 to ±20 mA DC or peak AC
Input Voltage Range
Better than 0.1% of full scale
DC Offset Voltage
Slew Rate
(10% to 90%, typical)
Large Signal
Bandwidth
(1% distortion)
DC to greater than 15 kHz
Small Signal
Bandwidth (-3dB)
DC to greater than 20 kHz
Settling Time (to 1%)
Less than 100 µs for a 0 to 5 kV step
Less than 100 ppm/hr, noncumulative
1/1000th of the high-voltage output
Better than 0.1% of full scale
Better than 1% of full scale
Individual push-button switch
Remote (TTL
compatible input)
TTL high (or open) turns off high-voltage output.
TTL low turns on high-voltage output.
A BNC provides a TTL low when the PD05034
is out of regulation for greater than 100 ms
*Measured using the true rms feature of the HP Model 34401A digital multimeter