Trek 601C User Manual

Trek Model 601C
High-Voltage Power Amplifier
Key Specifications
The Model 601C is a DC-stable, high-voltage power amplifier designed to provide precise control of output voltages. It features up to two independent amplifier channels in one enclosure and an all solid-state design for high slew rate, wide bandwidth and low­noise operation. The four-quadrant, active output design of the Model 601C sinks or sources current into reactive or resistive loads. These features are essential for achieving the accurate output response and high slew rates demanded by reactive loads.
! Output Voltage Range:
! Output Current Range:
! Slew Rate: Greater than 50 V/ !
Large Signal Bandwidth (1% distortion): DC to 8 kHz DC Voltage Gain: 100 V/V (a gain of 50 V/V is available for the ±500 V range only)
!
0 to ±500 V, 0 to -1 kV, or 0 to +1 kV DC or peak AC 0 to ±10 mA DC or 0 to ±20 mA peak AC
µs
Typical Applications Include
! Driving piezoelectric actuators ! Modulating electrooptics ! Electrostatically controlling ion beams ! Providing remote ON/OFF capabilities for automated
or computer controlled systems
Features and Benefits
DC accuracy is better than 0.1% of full scale
!
Precision
!
current for monitoring purposes or for use as feedback signals in a closed-loop system Remote high-voltage ON-OFF
!
Operation as a noninverting or inverting amplifier with a fixed gain
!
Different output voltage ranges, input configurations and voltage gain ratios are available; please contact Trek, Inc.
!
for more information
NIST-traceable Certificate of Calibration provided with each unit
!
compliant
!
voltage and current monitors provide low-voltage representations of the high-voltage output and load
TREK, INC. • 190 Walnut Street • Lockport, NY 14094 • USA • 800-FOR TREK
716-438-7555 • 716-201-1804 (fax) • www.trekinc.com • sales@trekinc.com
Features (cont.)
Digital Enable
An input providing a connection for a TTL compatible signal to turn on and off the high­voltage output.
Input Configuration**
Factory set as a noninverting amplifier, the Model 601C can be configured as an inverting amplifier.
Dynamic Adjustment
Graduated 1-turn panel potentiometer is used to optimize the AC response for various load parameters.
Mechanical
Dimensions
Single Channel
Instrument
222.3 mm H x 108 mm W 335 mm D (8.75” H x 4.25” W x 13.2” D)
Double
Instrument
Channel
433.8 mm H x 108 mm W 335 mm D (17” H x 4.25” W x 13.2” D)
Weight
Single Channel
4.3 kg (9.4 lb)
Double Channel
8.6 kg (18.8 lb)
HV Connector
SHV High Voltage Connector
Operating Conditions
Temperature
0°C to 40°C (32°F to 104°F)
Relative Humidity
To 85%, noncondensing
Altitude
To 2000 meters (6561.68 ft.)
Electrical
Line Voltage
Factory Set for one of two ranges: 90 to 127 V AC or 180 to 250 V AC, either at 48 to 63 Hz
Power Consumption
150 VA, maximum HV Cable
2 m, 66 pF per foot
Supplied Accessories
Operators’ Manual
PN: 23146
HV Output Cable Assembly, 3 m
PN: 43874R Line Cord
PN: N5002 (90 to 127 V AC) Contact Factory: (80 to 250 V AC)
Optional Accessories
HV Output Cable
PN: 43874R (3 meters)
Rack Mount Kits
PN: C4036, 603RA Full Rack Mount Kit PN: C4060, 603RA-2 Dual Instrument Rack Kit PN: C4008, Half-Rack Mount Kit
Model 601C Specifications
Performance
Output Voltage Range
0 to ±500 V, 0 to -1 kV, or 0 to +1 kV DC or peak AC
Output Current Range
0 to ±10 mA DC; 0 to ±20 mA peak AC
Input Voltage Range
0 to ±10 V DC or peak AC, noninverting
Input Impedance
25 kW, nominal
DC Voltage Gain
100 V/V (50 V/V avail. for ±500 V range only)
DC Voltage Gain Accuracy
Better than 0.1% of full scale DC Offset Voltage
Less than 500 mV
Output Noise
Less than 10 mV rms*
Slew Rate (10% to 90%, typical)
Greater than 50 V/µs
Small Signal Bandwidth (-3dB)
DC to greater than 30 kHz
Large Signal Bandwidth (1% distortion)
DC to greater than 8 kHz
Stability
Drift with Time
Less than 100 ppm/hr, noncumulative
Drift with Temp
Less than 50 ppm/°C
Voltage Monitor
Ratio
1/100th of the high-voltage output
DC Accuracy
Better than 0.1% of full scale
DC Offset Voltage
Less than ±5 mV
Output Noise
Less than 10 mV rms*
Output Impedance
0.1 W
Current Monitor
Ratio
0.5 V/mA
DC Accuracy
Greater than 1% of full scale
Offset Voltage
Less than ±10 mV
Output Noise
Less than 20 mV rms*
Output Impedance
0.1 W
Features
Output Voltage Configurations
Factory set for 0 to ±500 V DC or peak AC. Other available output voltage ranges are 0 to-1 kV or 0 to +1 kV DC or peak AC. This setting is customer specified.
*Measured using the true rms feature of the Hewlett Packard Model 34401A digital multimeter
**Please specify when ordering.
Copyright ã 2012 TREK, INC. All specifications are subject to change. 1229/DEC