Quality Refrigeration
OWNER’S MANUAL
Instructions for the installation, operation
and maintenance of Traulsen:
RMC Milk Cooler
RMC34, RMC49 & RMC58 Models
This Traulsen unit is built to our highest quality standards. We build our refrigerators and freezers this way as a matter of pride.
This philosophy has made Traulsen the leader in commercial refrigeration since 1938. We thank you for your choice and condence in Traulsen equipment and we know you will receive many years of utility from this equipment.
All Traulsen units are placed on a permanent record le with the service department. In the event of any future questions you
may have, please refer to the model and serial number found on the name tag afxed to the unit. Should you need service, call
us on our toll free number, 800-825-8220 between 7:30 am - 4:30 pm CST, Monday thru Friday. You may also log onto www.
traulsen.com for further information. It is our pleasure to help and assist you in every possible way.
INSTALLER
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION
INITIAL START DATE: SERIAL NO.
MODEL TYPE:
COMPANY/INDIVIDUAL NAME:
INSTALLER:
FORM NUMBER TR35944 (REV. 02-04-14) P/N 375-60324-00
TABLE OF CONTENTS
I. THE SERIAL TAG Page 1
II. RECEIPT INSPECTION Page 2
III. INSTALLATION
a-Location Page 2
b-Packaging Page 2
c-Installing/Adjusting the Casters Page 2
d-Cord & Plug Page 2
e-Power Supply Page 2
IV. OPERATION
a-Temperature Control Page 2
V. CARE & MAINTENANCE
a-Cleaning The Condenser/Filter Page 3
b-Replacing The Door Gaskets Page 3
c-Cleaning The Cabinet Surface Page 3
VI. WIRING DIAGRAM Page 4
VII. TROUBLE SHOOTING GUIDE Page 5
VIII. SERVICE ASSISTANCE
a-Service Check List Page 5
b-Service Information Page 5
IX. WARRANTIES Page 6
X. SERVICE PARTS LIST Page 7-8
FORT WORTH, TX.
SERIAL MODEL
VOLTS Hz PH
TOTAL CURRENT AMPS
MINIMUM CIRCUIT AMPS
MAXIMUM OVERCURRENT PROTECTION AMPS
LIGHTS WATTS
HEATERS AMPS
REFRIGERANT TYPE OZ
DESIGN PRESSURE HIGH LOW
REFRIGERANT TYPE OZ
DESIGN PRESSURE HIGH LOW
370-60294-00 REV (A)
I. THE SERIAL TAG
The serial tag is a permanently afxed label on which is
recorded vital electrical and refrigeration data about your
Traulsen product, as well as the model and serial number.
This tag is located in the left interior compartment on all
standard milk cooler models.
READING THE SERIAL TAG
• Serial = The permanent ID# of your Traulsen unit
• Model = The model # of your Traulsen unit
• Volts = Voltage
• Hz = Cycle
• PH = Phase
• Total Current = Maximum amp draw
• Minimum Circuit = Minimum circuit ampacity
• Lights = Light wattage
• Heaters = Heater amperage (Hot Food units only)
• Refrigerant = Refrigerant type used
• Design Pressure = High & low side operating
pressures and refrigerant charge
• Agency Labels = Designates agency listings
-1-
II. RECEIPT INSPECTION
III. INSTALLATION (continued)
All Traulsen products are factory tested for performance
and are free from defects when shipped. The utmost care
has been taken in crating this product to protect against
damage in transit.
You should carefully inspect your unit for damage during
delivery. If damage is detected, you should save all the
crating materials and make note on the carrier’s Bill Of
Lading describing the damage. A freight claim should be
led immediately. If damage is subsequently noted during or immediately after installation, contact our customer
care team to le a freight claim. There is a fteen (15)
day limit to le freight damage with the carrier. Under no
condition may a damaged unit be returned to Traulsen
without rst obtaining written permission (return authorization). You may contact Hobart/Traulsen customer
care at 800-333-7447 to request a return or le a claim.
III. INSTALLATION
III. a - LOCATION:
Select a proper location for your unit, away from extreme
heat or cold.
III. b - PACKAGING:
Your Traulsen unit is shipped from the factory bolted to a
sturdy wooden pallet in stretch wrapped material.
III. c - INSTALLING/ADJUSTING LEGS OR CASTERS:
III. d - CORD & PLUG:
All self-contained models are shipped standard with a NEMA
5-15P plug and 9 foot cord . Select only a dedicated electrical
outlet for power source.
NOTE: Do not under any circumstances, cut or remove the
round grounding prong from the plug, or use an extension
cord.
III. e - POWER SUPPLY:
The supply voltage should be checked prior to connection to
be certain that proper voltage for the cabinet wiring is available
(refer to the serial tag to determine correct unit voltage, see page
1). Make connections in accordance with local electrical codes.
Use qualied electricians.
Most exterior stainless steel surfaces have a protective
vinyl covering to prevent scratching during manufacturing, shipping and installation. After the unit is installed
in place of application peel, remove and discard the
covering from all surfaces.
To remove the wooden pallet, rst if at all possible, we
suggest that the cabinet remain bolted to the pallet during all transportation to the point of nal installation. The
bolts can then be removed with a 1/2” socket wrench.
Avoid laying the unit on its back for removal of the pallet.
NOTE: Traulsen does not recommend laying the unit
on its back. If you must, please allow the unit to remain in an upright position for 24 hours before plugging it in so that the compressor oils and refrigerant
may settle.
III. c - INSTALLING/ADJUSTING LEGS OR
CASTERS:
Casters are installed at the factory but will require adjustment upon installation.
To adjust the legs or casters, loosen the two bolts and
move leg or caster to desired location, spacing between
leg or caster not to exceed 48 inches. Leg or caster on
each end of the unit can not exceed 8 inches from the
end of the cabinet.
Use of a separate, dedicated circuit is required. Size wiring to
handle indicated load and provide necessary over current protec-
tor in circuit (see amperage requirements on the unit’s serial tag).
IV. OPERATION
IV. a - TEMPERATURE CONTROL:
The temperature is set at the factory but local conditions may
necessitate slight adjustment.
The temperature control is located behind the silver plug on the
front side of the system area (dial thermometer side). To adjust,
remove the plug turn the adjustment screw with a pair of pliers
a small amount at a time; turning clockwise lowers the temperature. An “OFF” position is fully counterclockwise and interrupts
power to the compressor and condenser fan only, not the entire
refrigerator.
-2-