Transmille EA015 User Manual

EA015
MULTI FUNCTION WORKSTATION ADAPTER
Ü
OPERATION MANUAL
EA015
Multi Function Workstation
Operation Manual
Version 1.00 April 2007 All product names are trademarks of their respective companies
EA015 MULTI FUNCTION WORKSTATION OPERATION MANUAL
Guarantee and service
Transmille Ltd. guarantees this instrument to be free from defects under normal use and service for a period of 1 years from purchase. This guarantee applies only to the original purchaser and does not cover fuses, or any instrument which, in Transmille’s opinion, has been modified, misused or subjected to abnormal handling or operating conditions.
Transmille’s obligation under this guarantee is limited to replacement or repair of an instrument which is returned to Transmille within the warranty period. If Transmille determines that the fault has been caused by the purchaser, Transmille will contact the purchaser before proceeding with any repair.
To obtain repair under this guarantee the purchaser must send the instrument in its original packaging (carriage prepaid) and a description of the fault to Transmille at the address shown below. The instrument will be repaired at the factory and returned to the purchaser, carriage prepaid.
Note : TRANSMILLE ASSUMES NO RESPONSIBILITY FOR DAMAGE IN TRANSIT
THIS GUARANTEE IS THE PURCHASER’S SOLE AND EXCLUSIVE GUARANTEE AND IS IN LEIU OF ANY OTHER GUARANTEE, EXPRESSED OR IMPLIED. TRANSMILLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS.
Transmille Ltd. Unit 4, Select Business Centre Lodge Road Staplehurst Kent TN12 0QW United Kingdom
Tel : +44 0 1580 890700 Fax : +44 0 1580 890711
EMail : sales@transmille.com Web : www.transmille.com
Transmille Ltd. Page 2
EA015 MULTI FUNCTION WORKSTATION OPERATION MANUAL
TABLE OF CONTENTS
GUARANTEE AND SERVICE.........................................................................................................................2
EA015 M
ULTI FUNCTION WORKSTATION...................................................................................................4
Design Notes ....................................................................................................................................5
Clamp Meters ..................................................................................................................5
Insulation Testers...........................................................................................................5
Process Control Calibrators..........................................................................................5
Digital Thermometers.....................................................................................................6
Optical Tachometers ......................................................................................................6
Features ............................................................................................................................................6
Using the EA015 with the Virtual Front Panel Software..............................................................8
Installing the Software ...................................................................................................8
Selecting a COM Port .....................................................................................................8
Operation of the Virtual Front Panel.............................................................................9
Functions : Thermocouple Simulation.........................................................................9
Functions : Tachometer Calibration...........................................................................10
Functions : Insulation Resistance ..............................................................................10
Functions : Insulation Test Voltage............................................................................11
Functions : Continuity Resistance & Current............................................................11
Functions : mA & mV Measurement...........................................................................12
STEP 1 : Enter an output value ...................................................................................13
STEP 2 : Setting to DC or AC.......................................................................................14
STEP 3 : Select a function ...........................................................................................14
STEP 4 : Select a Voltage / Current output ................................................................14
Terminals.......................................................................................................................15
STEP 5 : Set Output......................................................................................................16
Changing Output Values..............................................................................................16
Specifications.................................................................................................................................17
Care & Maintenance.......................................................................................................................18
Cleaning the Adapter.................................................................................................................18
Handling Precautions................................................................................................................18
Servicing Information................................................................................................................18
Transmille Ltd. Page 3
EA015 MULTI FUNCTION WORKSTATION OPERATION MANUAL
EA015 Multi Function Workstation
The multi function workstation provides a central work area with all connections routed conveniently to remote terminals mounted at the front of the adapter. The adapter extends the capabilities of the calibrator to include :
2 / 10 / 50 TURN CLAMP COIL INSULATION RESISTANCE OUTPUT CONTINUITY RESISTANCE OUTPUT INS. TEST VOLTAGE MEASUREMENT CONTINUITY CURRENT MEASUREMENT OPTICAL TACHOMETER CALIBRATION THERMOCOUPLE SIMULATION VOLTAGE MEASUREMENT : 3 RANGES CURRENT MEASUREMENT TO 30mA CALIBRATOR OUTPUT ROUTING :
VOLTAGE, CURRENT AND HIGH CURRENT TO DEDICATED WORKSTATION TERMINALS
Transmille Ltd. Page 4
EA015 MULTI FUNCTION WORKSTATION OPERATION MANUAL
Design Notes
Incorporating the advanced clamp coil, thermocouple simulation and tachometer calibration adapters as well as process control source / measure capabilities, this workstation adapter provides a versatile platform for efficient calibration of a wide range of equipment.
Clamp Meters
Using the built in 2, 10 and 50 turn coils, clamp meters can be accurately and quickly calibrated. Using a high accuracy balanced design both wound (AC only) & Magnetic field (hall effect) AC/DC clamp meters can be calibrated. Three coils in one provide the ability to calibrate a wide range of coils, from small lower clamps down to 10mm jaw diameter to larger 2000A clamps.
Insulation Testers
Insulation tester calibration is a common requirement and is now easy to perform using the workstation. Insulation to 2GOhms @ 1000V and continuity to 1kOhm is available from dedicated terminals. Using the measurement capabilities of the adapter interface, the workstation also provides insulation test voltage measurement to 1000V and continuity current measurement.
Process Control Calibrators
Source/measure process control calibrators are commonplace in industry and previously required several references to calibrate. The workstation integrates all the functions required to both source and measure the required signals.
Transmille Ltd. Page 5