Transmille EA008 User Manual

EA008
High Resistance / pA Measurement Adapter
Version 2.00 April 2009 All product names are trademarks of their respective companies
EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL
Guarantee and service
Transmille Ltd. guarantees this instrument to be free from defects under normal use and service for a period of 1 year from purchase. This guarantee applies only to the original purchaser and does not cover fuses, or any instrument, which in Transmille’s opinion, has been modified, misused or subjected to abnormal handling or operating conditions.
Transmille’s obligation under this guarantee is limited to replacement or repair of an instrument, which is returned to Transmille within the warranty period. If Transmille determines that the purchaser has caused the fault, Transmille will contact the purchaser before proceeding with any repair.
To obtain repair under this guarantee the purchaser must send the instrument in its original packaging (carriage prepaid) and a description of the fault to Transmille at the address shown below. The instrument will be repaired at the factory and returned to the purchaser, carriage prepaid.
Note: TRANSMILLE ASSUMES NO RESPONSIBILITY FOR DAMAGE IN TRANSIT
THIS GUARANTEE IS THE PURCHASER’S SOLE AND EXCLUSIVE GUARANTEE AND IS IN LEIU OF ANY OTHER GUARANTEE, EXPRESSED OR IMPLIED. TRANSMILLE SHALL NOT BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS.
Transmille Ltd. Unit 4, Select Business Centre Lodge Road Staplehurst Kent TN12 0QW United Kingdom
Tel: +44 0 1580 890700 Fax: +44 0 1580 890711
EMail: sales@transmille.com Web: www.transmille.com
Transmille Ltd. Page 2
EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL
TABLE OF CONTENTS
GUARANTEE AND SERVICE...............................................................................................................2
EA008 HIGH RESISTANCE & PA MEASUREMENT ADAPTER........................................................4
CONNECTIONS TO THE 3000 SERIES CALIBRATOR..................................................................................5
LOADING THE VFP SOFTWARE ONTO PC. ..............................................................................................5
BASIC OPERATION STEPS AND CONNECTION TO UUT..............................................................................5
Measure pA....................................................................................................................................5
Measure High Value resistance.....................................................................................................6
DETAILED VFP OPERATION..............................................................................................................6
CARE & MAINTENANCE......................................................................................................................9
Cleaning the Adapter.....................................................................................................................9
Handling Precautions...................................................................................................................10
Servicing Information...................................................................................................................10
Appendix A : Specifications
Transmille Ltd. Page 3
EA003 OPTICAL TACHOMETER CALIBRATION ADAPTER OPERATION MANUAL
EA008 High Resistance
& pA Measurement Adapter
Accurate Measurements down to pAmp levels.
Ideal for High resistance measurements to 1Tohm
Five measurement ranges
Supplied with Virtual Front Panel Software for PC.
The EA008 adapter for the 3041 & 3010 eliminates the need for a separate electrometer instrument. The low cost EA008 provides 5 current measurement ranges down to 10nA with a resolution of 1pA. The EA008 provides a ‘ virtual ground’ input impedance avoiding errors due to high input impedance often found on DMM’s with low current ranges.
By using the accurate high voltage output from the 3000 series calibrator together with the EA008 current measurement capability & the VFP software high value resistance measurements to be made with test voltages up to 1000V.
The virtual front panel program supplied as standard with the adapter provides a familiar user interface with features such as null, filter and auto range.