THE MULTI FUNCTION ELECTRICAL TEST SOLUTION
3200 SERIES
THE COMPLETE ELECTRICAL TEST SOLUTION
3200 SERIES
FAST, EFFICIENT ELECTRICAL CALIBRATION
INSULATION TESTER CALIBRATION
MULTI FUNCTION ELECTRICAL TESTING
INSULATION
TESTERS
MULTI FUNCTION TESTING
RCD / RCCB
TESTERS
Queen’s Award Winning Products Ideal for On-Site Calibration
The 3200 complements the 3000 Series
multi product calibrators, 8000 Series precision
multimeters and ProCal Calibration software. This
comprehensive range of Queen’s award winning
products provides the complete laboratory solution.
LOOP
TESTERS
RCD TESTER CALIBRATION
INSTALLATION
TESTERS
PATs / EARTH
BOND TESTERS
TO 30A
n
Robust, transportable design
n
Lightweight (10kgs)
n
Custom soft carry case option
n
Option for local line
Impedance compensation
PAT TESTER
CALIBRATION
LOOP TESTER
CALIBRATION
FOLD OUT FOR OVERVIEW
HIPOT /
BREAKDOWN
TESTERS
HV
SOURCES
The industry established 3200
Series provides by far the fastest
solution for the calibration of Loop
& RCD Testers, PATs and
INCREASED PRODUCTIVITY
REDUCED TEST TIMES = RAPID RETURN ON INVESTMENT
Insulation Testers, and also one of
the safest solutions for calibrating
Hi Pot/Breakdown testers.
Traditional testing practices
required many items of test
equipment and potential exposure
to hazardous voltageswith a typical
multi function tester taking up to 45
minutes to calibrate.
Using the 3200 Series, calibration
can be dramatically reduced to
typically 15 minutes enabling safe,
cost effective calibration to be put
into practice offering fast return on
investment.
Dedicated mains sockets for Loop, RCD & PAT testers on the 3200
front panel avoids the need to make connection of mains/line
voltages using 4mm type test leads. This important safety feature
eliminates any risk of shock to the engineer as connections are
made with standard mains / line plugs regional sockets available.
Loop and RCD testers can simply be plugged directly into the
dedicated front panel mains/line socket the advantages of this are:
þ ELIMINATES THE RISK OF SHOCK TO THE OPERATOR
REMOVES THE POSSIBILITY OF INCORRECT
þ
CONNECTION CAUSING UUT DAMAGE.
FASTER CALIBRATION WITH EASIER CONNECTION,
þ
LESS TRAINING FOR OPERATORS.
REDUCED UNCERTAINTY WITH FEWER CONNECTIONS
þ
UK
EURO
AUSTRALIAN
FOR LOOP IMPEDANCE CALIBRATION.
PAT testers plug directly into the 3200 IEC inlet socket using the calibrated lead supplied. The earth
bond lead clips on to the earth bond post. This terminal is electrically floating with respect to mains
earth allowing calibration of PATs which cannot be used on earthed appliances.
For flash voltage measurement the
external adapter allows the HV probe
from the PAT to be pushed down onto a
measurement point on the adapter.
The 3200 has been designed from the
outset as a high accuracy reference for
testing of electrical test equipment. Its
accuracy provides a superior stand off
ratio better than 4:1 essential for
accurate, repeatable testing.
3200 SERIES
17th EDITION ELECTRICAL TEST EQUIPMENT CALIBRATOR
CLEAR LED
MULTI
REGION
INDICATION OF
ACTIVE TERMINALS
DESIGN
REGION SPECIFIC
DEDICATED
SOCKET BUILT
INTO FRONT
UK / EURO /
AUSTRALIAN
+ ADDITIONAL
REGIONS
NO TRIP
PANEL FOR SAFE,
CONVENIENT
CONNECTION
TO TESTERS.
UK
DESIGN
EURO
AUSTRALIAN
SUITABLE
FOR RCD
PROTECTED
SUPPLIES
INSULATION TESTERS
TACTILE SOFT-KEYS LINKED
TO ON-SCREEN FUNCTIONSPECIFIC MENUS FOR CLEAR,
CONCISE USER OPERATION
Provides all the necessary
functionality required to calibrate
a wide range of insulation
testers.
CLEAR, BRIGHT LCD FOR
DISPLAY OF SELECTED
FUNCTIONS, SETTINGS
AND MEASUREMENTS
PATS & EARTH BOND TESTERS
A rapid testing solution for
calibrating all PAT functions.
Also ideal for earth/ground bond
testers up to 30A test current.
Resistance to 10GOhms Earth Bond Resistance & Current
Continuously variable Insulation
resistance to 10GOhms @ 1kV.
Resistance muliplyer option to
10 TOhms / 15kV available
10 precision resistance
values with current
measurement from 100mA
to 30A
Test Voltage Measurement Insulation Resistance
Measures insulation test
voltage & current with
16th/17th Edition compliance
Adjustable resistance to
10GOhms ideal for
checking pass/fail levels
Continuity Resistance & Current Flash Voltage & Leakage Current
AC Voltage Output
3 ranges to 1kOhm (variable
from 0.1Ohm to 20Ohms) and
current measurement to
320mA (@1Ohm)
5 AC voltage outputs at 50V•
100V•200V•230V•300V•400V
for calibrating voltage ranges
Load Testing
Class1&2flash voltage &
current measurement plus 3
AC leakage ranges to 7mA
Open circuit, short circuit and
0.13kVA load checks PAT
operation / run tests
FULL RANGE CONTROL AND
INDIVIDUAL DIGIT ADJUST VIA
OUTPUT CONTROL SECTION
RCD TESTERS
Simply plug in the RCD tester
to the RCD test socket and
start calibrating. Built-in UUT
fault detection.
RCD Current Measurement to 3A
RMS and peak current
measurements for all types of
tester using digital waveform
capture & analysis. Graphical
Indication of phase start
RCD Trip Time 20ms to 5s
Accurate & repeatable trip
times entered simply via the
keyboard provide easy
calibration
RCD Current Duration
The 3200 makes this normally
difficult measurement straight
forward with this dedicated
function
EASY MANUAL ENTRY OF
TEST VALUES USING
BUILT-IN NUMERIC KEYPAD
LOOP TESTERS
Calibrate these instruments
quickly and safely. Auto loop
option for accurate correction
of the supply line impedance.
Loop Resistance
10 precision resistance values incorporating line input
impedance either entered directly or obtained using the
auto loop measurement option
BREAKDOWN / HIPOT TESTERS
External adapter for calibration
reakdown / hipot testers.
of b
Measures ACV/DCV
and output current to 20mA
to 12kV
High Voltage Measurement to 12kV
4 Voltage ranges : AC/DC 3kV & 12kV
6 Current range : AC/DC 200uA, 2mA & 20mA
9 Load resistors for current measurements: 50kW (20mA)
to 20MW (20uA) @ 1kV
REAR INPUT
TERMINALS
OPTION
FOR CUSTOM
LOOP VALUES
DIGITAL
CONTROL
FOR QUICK
SELECTION
OF RANGES
& OUTPUTS
INTUITIVE INTERFACE DEDICATED BUTTONS
FOR EACH FUNCTION
OPTIONAL ADAPTERS
15kV INSULATION ADAPTER
n CALIBRATE UP TO 15kV
INSULATION TESTERS
nn2GOhm to 200GOhms /1TOhm
CONNECTS DIRECTLY TO 3200
*
REQUIRES 10GOhm OPT ON FITTED (200 GOhms AS STANDARD)
PAT FLASH TEST ADAPTER
n
CLASS 1 : 1.5kV TESTING
n
CLASS 2 : 3kV TESTING
n
CONNECTS DIRECTLY TO 3200
BREAKDOWN / HIPOT ADAPTER
n
3kV & 12kV AC/DC
MEASUREMENT RANGES
n
200uA / 2mA / 20mA
CURRENT RANGES
n
CONNECTS DIRECTLY TO 3200
HIGH VOLTAGE PROBE
nn12kV INPUT
n CONNECTS DIRECTLY TO 3200
IDEAL FOR TESTING HV
SOURCES
SAFE &
EASY TO
CONNECT
DIRECT
CONNECTION
TO SOCKETS
FOR SAFE
MAINS / LINE
TESTING
1-CLICK
FUNCTION
SELECT
DEDICATED
FUNCTION
KEYS FOR
EACH TYPE
OF TESTER
*