Transition Networks TN-GB-xM5 User Manual

COMPLIANCE INFORMATION
CISPR22/EN55022 Class A&B + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A & B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A & B limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A & B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A & B product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A & B. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A & B. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 2002 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33255.A
The TRANSITION Networks TN-GB-xM5 series Gigabit Interface Converter (GBIC) transceiver modules, designed to be installed in any GBIC port, connect multimode 1000BASE-SX OR singlemode 1000BASE-LX fiber-optic cable to the network through the GBIC connector.
Gigabit Interface Converter (GBIC)
Transceiver Modules
TN-GB-xM5
USER’S GUIDE
TN-GB-MM5
A 1000BASE-SX GBIC module for
1000BASE-SX multimode 850 nm fiber-
optic cable for a data link of up to 500 meters on 50/125 multimode fiber and up to 220 meters on 62.5/125 multimode fiber.
TN-GB-SM5
A 1000BASE-LX GBIC module for
1000BASE-LX singlemode 1300nm fiber-
optic cable for a data link of up to 10 kilometers.
Installation . . . . . . . . . . . . . . . . .2
Cable Specifications . . . . . . . . . .2
Technical Specifications . . . . . . .3
Compliance Information . . . . . . .4
PWR
LKG
LKM
RX
TX
1
0
0
0
B
A
S
E
S
X
/L
X
G
B
IC
INSTALLATION
Install GBIC Transceiver Module in Media Converter
To install GBIC transceiver module in Media Converter:
1. Position GBIC transceiver module at installation slot so that label faces up.
2. Carefully slide GBIC transceiver module into installation slot, aligning GBIC transceiver module with internal installation guides.
NOTE: Ensure that GBIC transceiver module is firmly seated against internal mating connector.
Install Cable
1. Locate or build 1000BASE-SX-compliant or 1000BASE-LX­compliant fiber cable with male TX to RX connectors installed at both ends.
2. Connect cable with connector installed at TX location on transceiver module to RX location on attached device.
3. Connect cable with connector installed at RX location on transceiver module to TX location on attached device.
CABLE SPECIFICATIONS
TN-GB-MM5 (multimode) 850 NM (SX)
Fiber Optic Cable Recommended: 62.5/125 µm multimode
Optional: 50/125 µm multimode Fiber-optic Transmitter Power: min: -9.5 dBm max: -4.0 dBm Fiber-optic Receiver Sensitivity: min: -17.0 dBm max: -3.0 dBm Typical Maximum* CableDistance: 220 meters on 62.5/125 µm multimode
500 meters on 50/125 µm multimode
TN-GB-SM5 (singlemode) 1300 NM (LX)
Fiber Optic Cable Recommended: 9 µm singlemode fiber Fiber-optic Transmitter Power: min: -9.5 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -19.0 dBm max: -3.0 dBm Typical Maximum* CableDistance: 10 kilometers
*Actual distance dependent upon physical characteristics of network installation.
TECHNICAL SPECIFICATIONS
Standards IEEE802.3z/D2 Gigabit Ethernet (1000BASE-SX and
1000BASE-LX); Revision 5.4 compliant [4] (GBIC)
Laser Class 1 Product ( Laser Klasse 1 Product ) which complies with the requirements of IEC 60825-1 and IEC 60825-2
Dimensions 3.4" x 0.86" x 5.0" (86mm x 22mm x 127mm) Weight 8 oz (approximate) Environment Typical Operating Temperature: 0-70°C (32°to 158°F )
Storage Temperature: -40°
to 85°C (-40° to 185°F)
Humidity 5-95%, non condensing Altitude 0-10,000 feet
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: TN-GB-xM5 SeriesGBIC Transceiver Modules Part Number(s): TN-GB-MM5, TN-GB-SM5 Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the TN-GB-xM5 to which this declaration refers is in conformity with the following standards.
EN 55022:1994; EN 55024:1998; FCC Part 15 Class A&B; EN 60950 A4:1997
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_April 1, 2002_____
Stephen Anderson, Vice-President of Engineering Date