Transition Networks PointSystem CPSMC1900-100, PointSystem CPSMC1910-100 User Manual

Page 1
Transition Networks
CPSMC19xx-100
19-Slot PointSystem™ Chassis
User’s Guide
(revision C)
CPSMC1900-100 CPSMC1910-100
Page 2
2
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Compliance Information
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equip­ment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency ener­gy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio inter­ference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2001-2004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electron­ic, or mechanical – without written permission from Transition Networks.
Printed in the U.S.A.
33242.C
CAUTION: THE RJ CONNECTORS ON THE INDIVIDUAL MEDIA CONVERTER SLIDE-IN-MODULES ARE NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten ver­stösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Page 3
3
Table of Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
1.2 Unpacking the CPSMC19xx-100 Equipment . . . . . . . . . . . . . . . . .6
2 Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1 Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1.1 Chassis Face Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
2.1.2 Calculating the Power Consumption . . . . . . . . . . . . . . . . . . . . . .7
2.1.3 Installing the Media Converter Slide-in-Modules . . . . . . . . . . . . .8
2.1.4 Replacing the Media Converter Slide-in-Modules . . . . . . . . . . . .9
2.2 Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2.2.1 Three Types of Management Modules . . . . . . . . . . . . . . . . . . . .10
2.2.2 Installing the Management Modules . . . . . . . . . . . . . . . . . . . . .11
2.2.3 Replacing the Management Modules . . . . . . . . . . . . . . . . . . . . .12
2.3 Optional LED Slide-in-Module . . . . . . . . . . . . . . . . . . . . . . . . . . .13
3 Powering the CPSMC19xx-100 . . . . . . . . . . . . . . . . . . . . . . .14
3.1 AC Power Supply Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
3.2 DC Power Supply Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
3.3 Optional Dual Power Supply Modules . . . . . . . . . . . . . . . . . . . . .18
3.4 Power Supply Module Maintenance . . . . . . . . . . . . . . . . . . . . . .19
3.4.1 Primary/Secondary-Management/Manual Switch . . . . . . . . . . . .19
3.4.2 Installing the Power Supply Module . . . . . . . . . . . . . . . . . . . . . .20
3.4.3 Replacing the Power Supply Module . . . . . . . . . . . . . . . . . . . . .21
3.4.4 Replacing the Power Supply Fuses . . . . . . . . . . . . . . . . . . . . . . .22
3.5 Optional Fan Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
4 CPSMC19xx-100 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
4.1 Installing the CPSMC19xx-100 Chassis . . . . . . . . . . . . . . . . . . . .25
4.1.1 Table Top Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
4.1.2 Standard 19-inch Rack Installation . . . . . . . . . . . . . . . . . . . . . . .25
4.1.3 Grounding Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
4.2 Cascade Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
4.3 Connecting the Slide-in-Modules to the Network . . . . . . . . . . . . .30
4.4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
5 Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 4
4
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Contact Us . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 5
5
introduction
1 Introduction
1.1 Description
The Transition Networks CPSMC19xx-100 19-Slot PointSystem™ chassis is a 19­inch, rack-mountable chassis for selected Transition Networks media converter slide-in-modules. The CPSMC19xx-100 allows the network administrator to con­nect various copper and fiber-optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3, and OC-12 and many others. The CPSMC19xx­100 provides installation space for up to 19 single-slot media converter slide-in­modules in the front of the unit.
With an installed PointSystem™ management module (P/N CPSMM-120 or -200), the CPSMC19xx-100 can be managed and monitored via:
An SNMP application such as Transition Networks FocalPoint™ manage- ment software installed at a remote Network Management Station (NMS).
A remote Web browser.
A command-line interface (CLI) at an attached terminal.
A command-line-interface (CLI) at a remote Telnet connection.
The management modules also make it possible to control up to eight (8) cascaded CPSMC19xx-100 chassis fully populated with media converter slide-in-modules.
The CPSMC19xx-100 is equipped with an AC or DC Power Supply installed in the back of the chassis. An extra installation space is available for an optional redun­dant power supply (AC or DC) or an optional fan module.
Finally, the CPSMC19xx-100 also comes equipped with a pair of grounding lugs for providing proper grounding of the chassis.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Management Module Installed Slide-in-Module Open Slot
PWR
TX
10BASE-T
RX
LNK
RESET
DB-9
RXF
RXC
TX
10BASE-FL
RX
10BASE-T
LKF
CETTF100
PWR
PWR
LKS
LKS
PWR
LKM
LKM
LKC
TX
TX
Singlemode
Singlemode
RX
RX
TX
TX
Multimode
Multimode
RX
RX
CFMFF100
CFMFF100
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Power Supply Module
(AC module is pictured)
I 0
Grounding Lugs
Extra Installation
Space
Page 6
6
introduction
1.2 Unpacking the CPSMC19xx-100 Equipment
Use the following list to verify the shipment:
Item Part Number
19-Slot chassis with AC Power Supply CPSMC1900-100
19-Slot chassis with DC Power Supply CPSMC1910-100
PointSystem™ Chassis Face Plates (19) CPSFP-200
Power Cord (varies by country)
User’s Guide 33242
The following items are optional accessories for the CPSMC19xx-100 19-Slot PointSystem™ chassis:
Item Part Number
Redundant AC Power Supply Module CPSMP-200 (optional)
Redundant 48-VDC Power Supply Module CPSMP-210 (optional)
Redundant Fan Module CPSFM-200 (optional)
LED Slide-in-Module CPSLD-100
Single-Slot Master Management Module CPSMM-120 (optional)
Dual-Slot Master Management Module CPSMM-200 (optional)
FocalPoint™ Software Disk A1-7227 (included with the management modules)
Expansion Management Module CPSMM-210 (optional)
Management Module Cascade Connector 6026 (optional)
Rack Mount Ears CPSRE-230 (optional)
Selectable media converter slide-in-module(s) (various P/N) - (optional)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 7
7
CPSMC19xx-100 PointSystem™Chassis
slide-in-modules
2 Slide-in-Modules
2.1 Media Converter Slide-in-Modules
Transition Networks media converter slide-in-modules, installed in slots at the front of the chassis, allow the network administrator to connect various copper and fiber­optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3, and OC-12 as well as many others (see www.transition.com for a complete listing.)
NOTE: Refer to the user’s guide that comes with each media converter slide-in­module for cable, connector, and LED indicator information specific to that media converter slide-in-module.
2.1.1 Chassis Face Plates
CAUTION: Slots in the CPSMC19xx-100 chassis without a slide-in-module installed MUST have a protective chassis face plate (P/N CPSFP-200) covering the empty slot for Class A compliance.
Install a chassis face plate over any unused chassis slot by aligning the hole in the face plate with the threaded hole in the chassis. Secure the face place with the enclosed bolt.
2.1.2 Calculating the Power Consumption
CAUTION: Before installing the media converter slide-in-modules, refer to the
power consumption data for each individual media converter (provided in the user’s guide shipped with each media converter). The combined power consumption of all devices must not exceed the available power supply. Failure to observe this caution could result in diminishing system reliability.
In other words, the combined power requirements of the CPSMC19xx-100 chassis
plus all slide-in-modules must be less than the available power.
Contact Transition Networks Tech Support to ensure the power requirements for your specific application do not exceed the available power.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Chassis Face Plate
Page 8
8
CPSMC19xx-100 PointSystem™Chassis
slide-in-modules
2.1.3 Installing the Media Converter Slide-in-Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precau-
tions when installing the media converter slide-in-module(s) into the chassis.
Failure to observe this caution could result in damage to, and subsequent failure of, the media converter slide-in-module(s).
NOTE: The media converter slide-in-modules can be installed in any installation
slot, in any order.
To install the media converter slide-in-module into the CPSMC19xx-100 chassis:
1. If a chassis face plate is covering the installation slot, remove the face plate from
the installation slot by removing the one (1) screw that secures the plate to the front of the chassis.
NOTE: If the slide-in-module requires two slots, remove the face plates from two (2) adjacent installation slots.
2. Align the slide-in-module with the chassis installation slot so that the panel fas-
tener screw is at the top of the module.
3. Carefully slide the slide-in-module into the installation slot, while aligning the
module’s circuit board with the installation guides.
NOTE: Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the
module to the chassis.
5. Repeat steps 1 through 4 for any additional media converter slide-in-module(s).
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
PWR
TX
10BASE-T
RX
LNK
RESET
DB-9
RXF
RXC
TX
10BASE-FL
RX
10BASE-T
LKF
CETTF100
PWR
LKC
RXF
RXC
TX
RX
10BASE-T
LKS
LKM
TX
Singlemode
LKF
RX
TX
Multimode
10BASE-FL
RX
CFMFF100
PWR
LKS
LKM
TX
Singlemode
RX
PWR
LKC
TX
Multimode
RX
CFMFF100
PWR
PWR
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
LNK
COL
Link Alert
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
PWR
SPD
FRX
CRX
TX
10/100SX
RX
10/100TX
CFETF110
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
Panel Fastener Screw
PWR
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Page 9
9
CPSMC19xx-100 PointSystem™Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.1.4 Replacing the Media Converter Slide-in-Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precau- tions when replacing media converter slide-in-module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the media converter slide-in-module(s).
NOTE: The media converter slide-in-modules can be hot-swapped.
To replace a media converter slide-in-module in the CPSMC19xx-100 chassis:
1. Remove the slide-in-module to be replaced by loosening the panel fastener
screw that secures the module to the chassis front. Slide the module from the chassis.
2. Align the replacement slide-in-module with the chassis installation slot so that
the panel fastener screw is at the top.
3. Carefully slide the replacement slide-in-module into the installation slot, while
aligning the module’s circuit board with the installation guides.
NOTE: Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the
module to the chassis.
PWR
TX
10BASE-T
RX
LNK
RESET
DB-9
RXF
RXC
TX
10BASE-FL
RX
10BASE-T
LKF
CETTF100
PWR
LKC
RXF
RXC
TX
RX
10BASE-T
LKS
LKM
TX
Singlemode
LKF
RX
TX
Multimode
10BASE-FL
RX
CFMFF100
PWR
LKS
LKM
TX
Singlemode
RX
PWR
LKC
TX
Multimode
RX
CFMFF100
PWR
PWR
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
LNK
COL
Link Alert
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
PWR
SPD
FRX
CRX
TX
10/100SX
RX
10/100TX
CFETF110
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
Panel Fastener Screw
PWR
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Page 10
10
CPSMC19xx-100 PointSystem™Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.2 Management Modules
Optional network management is provided by SNMP software embedded in Transition Networks
PointSystem
management module(s) that can be installed in
the CPSMC19xx-100 chassis.
Transition Networks provides two such modules:
CPSMM-120 Single-Slot Master Management Module.
CPSMM-200 Dual-Slot Master Management Module.
Along with an additional expansion module:
CPSMM-210 Single Slot Expansion Management Module.
2.2.1 Three Types of Management Modules
CPSMM-120 Single-Slot Master Management Module
The optional CPSMM-120 Single-Slot Master Management Module can be installed to enable network management of a single CPSMC19xx­100 chassis.
Refer to the CPSMM-120 user’s guide for more information on the CPSMM-120 Single-Slot Master Management Module.
CPSMM-200 Dual-Slot Master Management Module
The optional CPSMM-200 Dual-Slot Master Management Module can also be installed in the CPSMC19xx-100 chassis to enable network management.
This module has all of the features of the CPSMM-120 plus a pair of cascade ports, which allow multiple PointSystem™ chassis to be connected.
Note also that this module requires two adjacent slots in the CPSMC19xx-100 chassis for installation.
Refer to the CPSMM-200/-210 user’s guide for more information on the CPSMM-200 Dual-Slot Master Management Module.
CPSMM-210 Single-Slot Expansion Management Module
The CPSMM-210 is used with the CPSMM-200 to connect up to eight (8) PointSystem™ chassis into one manageable stack.
Refer to the CPSMM-200/-210 user’s guide for more information on the CPSMM-210 Single-Slot Expansion Management Module.
NOTE: See section 4.3 Cascade Option for details on connecting multi- ple CPSMC19xx-100 chassis.
10BASE-T
SERIAL
CPSMM120
PWR
TX
RX
LNK
RESET
10BASE-T
IN
OUT
CPSMM200
TX
RX
Power
IN
OUT
PWR
LNK
RESET
DB-9
RESET
CPSMM210
Page 11
11
CPSMC19xx-100 PointSystem™Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.2.2 Installing the Management Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precau-
tions when installing the management module into the CPSMC19xx-100 chassis.
Failure to observe this caution could result in damage to, and subsequent failure of, the management module.
NOTE: Transition Networks recommends installing the management module into
the left-most installation slot to keep the management module cables separate from the media converter cables.
To install a management module into the CPSMC19xx-100 chassis:
1a. CPSMM-200 Dual-Slot Master Management Module: If
chassis face plates are covering the installation slots, remove the face plates from the two (2) installation slots at the far-left position of the chassis.
1b. CPSMM-120 Single-Slot Master Management Module OR
CPSMM-210 Single-Slot Expansion Management Module:
If chassis face plates are covering the installation slots, remove the face plate from the one (1) installation slot at the far-left position of the chassis.
2. Align the management module with the chassis installation slot so that the
panel fastener screw is at the top of the module.
3. Carefully slide the management module into the installation slot, while aligning
the module’s circuit board with the installation guides.
NOTE: Ensure that management module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the
management module to the chassis.
PWR
TX
RX
LNK
RESET
INIT
DB-9
12C
12C-1TERM
Panel Fastener Screw
RESET
Pwr
INIT
TERM
Panel Fastener Screw
Page 12
12
CPSMC19xx-100 PointSystem™Chassis
slide-in-modules
2.2.3 Replacing the Management Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precau- tions when replacing the media converter slide-in-module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the management module(s).
NOTE: The management modules can be replaced while the chassis remains pow- ered. However, you must configure a new IP address for the replacement manage­ment module. For more information, see the FocalPoint™ 2.0 user’s guide on the
enclosed application CD or on-line at www.transition.com.
To replace a management module in the CPSMC19xx-100 chassis:
1. Remove the management module to be replaced by loosening the panel fasten-
er screw that secures the module to the chassis front. Slide the module from the chassis.
2. Align the replacement Management module with the installation slot so that the
panel fastener screw is at the top.
3. Carefully slide the replacement management module into the installation slot,
while aligning the module’s circuit board with the installation guides.
NOTE: Ensure that the management module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the
module to the chassis.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
RESET
Pwr
INIT
TERM
Panel Fastener Screw
Page 13
13
CPSMC19xx-100 PointSystem™ Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.3 Optional LED Slide-in-Module
The optional LED slide-in-module (CPSLD-100) allows the network administrator to determine at a glance which power supplies are installed and in use.
The LED module can be installed in any slot in the front of the chassis. The proce­dure to install and replace it is the same as any other slide-in-module. (See sec­tions 2.1.3 Installing the Media Converter Slide-in-Modules and section 2.1.4 Replacing the Media Converter Slide-in-Modules for more information.)
When the chassis is powered on, the installed LED slide-in-module goes through a self-test where the four LEDs will light up in sequence. After the self-test, the LEDs indicate the current power supply operating conditions.
Power and In Use LED indicators are provided for each installed power supply Modules (see the figure to the right).
The numerical designation on the LED slide-in-mod­ules is as follows:
1 Refers to the power supply installed in the left
installation slot (when looking at the chassis from the rear).
2 Refers to the power supply installed in the right
installation slot (when looking at the chassis from the rear).
See chapter 3 Powering the CPSMC19xx-100 for more information on the power supply for the CPSMC19xx-100 chassis.
r
Panel Fastene
Power
1
In Use
Power
2
In Use
Screw
Page 14
14
CPSMC19xx-100 PointSystem™Chassis
power supply
3 Powering the CPSMC19xx-100
3.1 AC Power Supply Module
The CPSMC1900-100 PointSystem™ chassis is equipped with an AC power supply module (P/N CPSMP-200) installed in the back of the chassis. The power supply module supplies power to the chassis, installed media converter slide-in-modules, management modules, and the optional fan module.
The components of the AC power supply module include:
An AC power cord that distributes power from an external outlet to an AC
power connector on the power supply module.
An On/Off switch that, when set to “I”, allows the module to supply power to
the chassis and any installed modules.
•A power LED indicator.
•A fan to prevent the power supply module from overheating.
An fuse installed in a fuse holder.
Optional Redundant AC Power Supply Module
An extra installation space is available in the back of the chassis for installing an optional redundant AC power supply module (P/N CPSMP-200).
See section 3.4 Power Supply Module Maintenance for instructions on installation.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Fan Power LED
AC Power Connector
Fuse Holder
Extra Installation
Space
On/Off Switch
I 0
I 0
AC Power Cord
I 0
I 0
Page 15
15
power supply
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Powering the AC Power Supply Module
To power the CPSMC1900-100 PointSystem™ chassis through the AC power sup­ply module:
1. Set the On/Off switch to “0”.
2. Connect female end of the power cord to the AC power connector on the power
supply module.
3. Plug the male end of the power cord into the correct voltage AC rack or wall
socket.
4. Set the On/Off switch to “I”.
5. Verify that the chassis is powered by observing the illuminated power LED and
fan operation.
AC Power Connector
Fan Power LED
On/Off Switch
I
0
I 0
AC Power Cord
Page 16
16
CPSMC19xx-100 PointSystem™Chassis
power supply
3.2 DC Power Supply Module
The CPSMC1910-100 PointSystem™ chassis is equipped with a DC power supply module (P/N CPSMP-210) installed in the back of the chassis. The power supply module supplies power to the chassis, installed media converter slide-in-modules, management modules, and the optional fan module.
The components of the DC power supply module include:
A set of three (3) external power connectors that distribute power from an exter-
nal 48-VDC outlet to a chassis ground connector, a positive (+) connector, and a negative (-) connector on the DC power supply module.
An On/Off switch that, when set to “I”, allows the module to supply power to
the chassis, and any installed modules.
•A power LED indicator.
•A fan to prevent the power supply module from overheating.
•A fuse installed on the power supply module’s circuit board.
Optional Redundant DC Power Supply Module
An extra installation space is available in the back of the chassis for installing an optional redundant DC power supply module (P/N CPSMP-210).
See section 3.4 Power Supply Module Maintenance for instructions on installation.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
External Power Connectors
Fan Power LED
Fuse (on the circuit board) Extra Installation
On/Off Switch
-
+
0
I
Space
-
+
0
I
-
+
0
I
Page 17
17
power supply
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Read and follow all warning notices & instructions marked on the product or included in the manual.
CAUTION: All installation and service must be performed by qualified service personnel.
CAUTION: Ensure that the external power source is NOT powered and that the On/Off switch is set to “0” when connecting the 48-VDC power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the 48-VDC power supply module.
Powering the DC Power Supply Module
This product is intended to be used in a restricted access location. Proper earthing
(grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation requirements and local electrical codes. Prior to installation, use a voltmeter/ohm­meter to check the wiring for the presence of earth ground.
A readily accessible disconnect device as part of the building installation shall be
incorporated into the fixed wiring. The disconnect device (a 48 VDC, 15 or 20A circuit breaker or switch) must be included in the ungrounded supply conductor. Overcurrent protection must be a 48 VDC, 15 or 20A fuse or circuit breaker.
To power the CPSMC1910-100 chassis through the DC power supply module:
1. Set the On/Off switch to “0”.
2. Verify that the external power source is NOT powered.
3. Connect the +48-VDC terminal to the chassis external power connector marked
“+”. Turn the terminal screw clockwise to secure.
4. Connect the -48-VDC terminal to the chassis external power connector marked
“-”. Turn the terminal screw clockwise to secure.
5. Connect the ground terminal to the chassis external power connector marked
“chassis ground”. Turn the terminal screw clockwise to secure.
6. Power up the external power source.
7. Set the DC power supply module power switch to “I”.
8. Verify that chassis is powered by observing the illuminated power LED and fan
operation.
External Power Connectors
Fan Power LED
GND
On/Off Switch
-
+
+
0
I
Page 18
18
CPSMC19xx-100 PointSystem™Chassis
power supply
3.3 Optional Dual Power Supply Modules
Alternatively, both an AC power supply module and a DC power supply module can be installed in the same chassis.
NOTE: The drawing below shows the AC module in the left installation slot and the DC module in the right, However, either power supply module can be installed in either installation space.
See section 3.4 Power Supply Module Maintenance for instructions on installation.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I 0
-
+
0
I
Page 19
19
CPSMC19xx-100 PointSystem™Chassis
power supply
3.4 Power Supply Module Maintenance
3.4.1 Primary/Secondary-Management/Manual Switch
Both the AC (CPSMP-200) and DC (CPSMP-210) power supply modules have a set of Primary/Secondary-Management/Manual switches installed on the circuit board.
Management/Manual Switch
The Management/Manual switch allows the PointSystem™ software to control and override the physical setting on the Primary/Secondary switch.
When set to ‘Management’, the power supply module has the default setting of
‘Primary’ unless changed, at the software interface, to ‘Secondary’.
When set to ‘Manual’, the power supply module is set by the
Primary/Secondary switch. The software interface cannot change the setting.
Primary/Secondary Switch
The Primary/Secondary switch allows the power supply module to be configured as the ‘Primary’ or as the ‘Secondary’ power supply module.
As the ‘Primary’ power supply, it provides power to the entire chassis.
As the ‘Secondary’ power supply, it waits in stand-by, ready to supply power to
the chassis in the event of power failure from the ‘Primary’ power supply.
Configuring Two Power Supply Modules
For load sharing, where each module supplies power to half the chassis, set
both power supply modules to ‘Primary’.
For back-up power supply, set one power supply module to ‘Primary’ (which
supplies power to the entire chassis) and the other to ‘Secondary’. In this mode, the secondary module is in stand-by and takes over in the event of a power fail­ure of the primary module.
NOTE: At least one power supply module must be set to ‘Primary.’ If both mod­ules are set to ‘Secondary,’ neither will supply power to the chassis.
CAUTION: In a 0 - 60°C (32 - 140°F) environment, two power supplies must be installed and both must be configured for load sharing.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
t
Primary
Managemen
I
0
Secondary
Manual
Page 20
20
CPSMC19xx-100 PointSystem™Chassis
power supply
WARNING: Do NOT connect the power supply module to the external power before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
3.4.2 Installing the Power Supply Module
The AC and DC modules are installed in the same manner.
NOTE: At least one power supply module must be set to ‘Primary.’ If both mod­ules are set to ‘Secondary,’ neither will supply power to the chassis.
1. Remove the power supply module protective plate from the installation slot by
removing and retaining the two (2) screws that secure the plate to the chassis.
2. Set the Primary/Secondary switch and the Management/Manual switch, if nec-
essary. (See section 3.4.1)
3. Carefully slide the power supply module into the installation slot, aligning the
power supply module with the installation guides. Ensure that the power sup­ply module is firmly seated inside the chassis.
4. Carefully install the two (2) screws (retained in Step 1) through the power sup-
ply module into the chassis, rotating clockwise to secure.
5. Connect the power supply module to the external power supply (AC: see page
15; DC: see page 17).
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I 0
I 0
I 0
Page 21
21
CPSMC19xx-100 PointSystem™Chassis
power supply
WARNING: Do NOT connect the Power Supply Module to the external power before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
3.4.3 Replacing the Power Supply Module
The AC and DC modules are replaced in the same manner.
Both the AC (CPSMP-200) and DC (CPSMP-210) power supply modules may be hot swapped provided the module to be swapped has been disconnected from the
external power source and the On/Off switch has been set to “0”.
NOTE: At least one power supply module must be set to ‘Primary.’ If both mod-
ules are set to ‘Secondary,’ neither will supply power to the chassis.
1. Set the power supply module power switch to “0”.
2. Disconnect the power supply module from the external power source.
3. Remove the two (2) screws that secure power supply module to the chassis.
Retain the screws for installing the replacement power supply module.
4. Slide the power supply module from the chassis.
5. Set the Primary/Secondary switch and the Management/Manual switch on the
replacement power supply module, if necessary. (See section 3.4.1)
6. Carefully slide the replacement power supply module into the installation slot,
aligning the module with the installation guides. Ensure that the the module is firmly seated inside the chassis.
7. Carefully install the two (2) retained screws through the power supply module
into the chassis, rotating clockwise to secure.
8. Connect the power supply module to the external power source. (AC: see page
15 / DC: see page 17.)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I 0
I 0
Page 22
22
CPSMC19xx-100 PointSystem™chassis
power supply
WARNING: Do NOT connect the power supply module to the external power before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
3.4.3 Replacing the Power Supply Fuses
Replacing the AC Fuse
CAUTION: Wear a grounding device and observe electrostatic discharge precau­tions when replacing the fuse in the power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
NOTE: Replace the fuse only with the same size and rating. Failure to observe this
caution could result in equipment damage.
1. Set the AC power supply module power switch to “0”.
2. Disconnect the power supply module from the external power source.
3. From the inside edge of the power receptacle, insert a small flat blade screw-
driver into the groove on the front, inside edge of the fuse holder and carefully pry the fuse holder from the power supply module.
4. Carefully remove the fuse from the fuse holder.
5. Install a same size and rating replacement fuse in the fuse holder.
6. Return the fuse holder and fuse to the installation position in the power supply
module. Snap the fuse holder into place.
7. Connect the power supply module to the external power source (see page 15).
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I
0
Fuse Holder
Fuse
Page 23
23
CPSMC19xx-100 PointSystem™chassis
power supply
WARNING: Do NOT connect the power supply module to the external power before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
Replacing the DC Fuse
CAUTION: Wear a grounding device and observe electrostatic discharge precau­tions when replacing the fuse in the power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
NOTE: Replace the fuse only with the same size and rating. Failure to observe this
caution could result in equipment damage.
1. Set the DC power supply module power switch to “0”.
2. Disconnect the power supply module from the external power source.
3. Remove the power supply module by removing the two (2) screws that secure
the module to the chassis. Slide the module from the chassis.
4. Remove the fuse from the fuse holder.
5. Install a same size and rating replacement fuse in the fuse holder.
6. Slide the power supply module into the installation slot, aligning the module
with the installation guides. Ensure that the module is firmly seated inside the chassis.
7. Install the two (2) retained screws through the power supply module into the
chassis, rotating clockwise to secure.
8. Connect the power supply module to the external power source (see page 17).
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I 0
Fuse Holder
0
I
Fuse
Page 24
24
CPSMC19xx-100 PointSystem™chassis
power supply
3.5 Optional Fan Module
The optional fan module (CPSFM-200) can be installed in the extra installation space in the back of the CPSMC19xx-100 chassis to provide additional cooling for the entire chassis.
CAUTION: Wear a grounding device and observe electrostatic discharge precau­tions when installing the fan module into the chassis. Failure to observe this cau­tion could result in damage to, and subsequent failure of, the fan module.
NOTE: The fan module can be hot-swapped.
To install the fan module into the CPSMC19xx-100 chassis:
1. Remove the protective plate from the installation slot by removing and retain-
ing the two (2) screws that secure the plate to the chassis.
2. Carefully slide the fan module into the installation slot, aligning the module
with the installation guides. Ensure the module is firmly seated inside the chassis.
3. Carefully install the two (2) retained screws through the fan module into the
chassis, rotating clockwise to secure.
4. Verify that the fan module is powered by observing the fan operation.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I 0
I 0
Page 25
25
CPSMC19xx-100 PointSystem™Chassis
chassis
4 CPSMC19xx-100 Chassis
4.1 Installing the CPSMC19xx-100 Chassis
The CPSMC19xx-100 can be installed in a standard 19-inch rack or on a table, shelf, or other stable surface.
CAUTION: Install the chassis so that the air flow around it is not restricted.
4.1.1 Table-Top Installation
The CPSMC19xx-100 chassis is shipped with nine (9) rubber feet for optional instal­lation on a table or other flat, stable surface in a well-ventilated area. If table-top installation is desired, remove the rubber feet from the card and place them on the bottom of the chassis. Distribute the feet so that the chassis is level when placed upright.
4.1.2 Standard 19-inch Rack Installation
The maximum recommended ambient temperature (Tmra) for the CPSMC19xx-100 chassis is 50°C. (60°C when using load-sharing power supply modules) If the CPSMC19xx-100 chassis is installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the the rack environment may be greater than room ambient.
NOTE: Rack-mounted equipment must be reliably grounded. Power supply con-
nections other than direct connections to the branch circuit (e.g., use of power strips) should be employed.
The CPSMC19xx-100 chassis is designed so that the installation brackets can be installed to align the chassis either flush against the front or back edge of the rack or recessed from the front or back edge of the rack.
WARNING: Select mounting bracket locations on the chassis that will keep the chassis balanced when mounted in the rack. Failure to observe this warning could allow the chassis to fall, resulting in equip­ment damage and/or possible injury to personnel.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Flush Alignment
at front
Recessed Alignment
at front
Flush Alignment
at back
Recessed Alignment
at back
Page 26
26
CPSMC19xx-100 PointSystem™Chassis
chassis
To install the CPSMC19xx-100 chassis into a standard 19-inch rack:
1. Determine the preferred alignment of the chassis in the rack.
NOTE: Installation bracket mounting screws are provided. Rack mount screws and clip nuts are NOT provided.
2. Locate six (6) installation bracket mounting screws (provided) for each chassis
to be installed.
WARNING: Mount the chassis evenly and securely onto the rack. Failure to observe this warning could allow the chassis to fall, resulting in equipment damage and/or possible injury to personnel.
3. Align the universal mounting bracket in the selected position against the side of
the chassis so that the chassis installation holes are visible through the univer­sal bracket installation holes.
4. Using a Phillips screwdriver, install the three (3) screws through the mounting
bracket into the installation holes on side of the chassis.
5. Repeat steps 3 and 4 for the second mounting bracket.
6. Locate four (4) screws (not provided) and optional clip-nuts (not provided) for
each chassis to be installed.
7. Carefully align the chassis at a secure and level position between the 19-inch
site rack mounting rails.
8. Install two (2) screws through the right bracket into the right mounting rail and
two (2) screws through the left bracket into the left mounting rail, using the clip nuts to secure, if necessary.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 27
27
CPSMC19xx-100 PointSystem™ Chassis
chassis
4.1.3 Grounding Lugs
The CPSMC19xx-100 comes equipped with grounding lugs, which are provided for a grounding conductor wire terminated with a two-hole, compression-type, ground- ing connector. The grounding wire -- which must be a copper conductor -- is not included with the chassis and must be provided by the customer/installer.
The electrical conducting path from the chassis must:
Flow via the grounding lugs to the Common Bonding Network (CBN) for tele-
com installations; or to an alternate approved grounding system (if required) for non-telecom installations,
Be of sufficiently low impedance to conduct fault currents likely to be imposed
on the chassis, and
Enable proper operation of any over-current protection devices.
The two-hole, compression-type, grounding connector must be fastened to the grounding lugs with the enclosed, anti-rotation star-washers and lug-nut fasteners. The required torque to the fasteners is specified by the connector’s manufacturer.
To properly ground the CPSMC19xx-100 chassis:
1. Obtain one (1) properly-terminated, grounding conductor (12 AWG copper
wire gauge or larger) with a two-hole, compression-type, grounding connector. Note the manufacturer's applied torque that is required for the connector.
2. Attach the grounding conductor to the chassis by placing the two-hole, com-
pression-type connector onto the grounding lugs and fasten with appropriate lock-washers and lug-nuts at the proper torque.
3. Attach the opposite end of the properly-terminated grounding conductor to the
Common Bonding Network (CBN) for telecom installations, or to an approved grounding system (if required) for non-telecom installations.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
p
Grounding lugs
(6-32, 1/8" diam.)
3/4-inch
spacing
Two-hole, compression-type grounding connector (not included)
Star washer (included)
Lug nuts (included)
12 AWG copper wire
(not included)
Grounding Lugs
I 0
Grounding Wire with a two-hole,
com
ression-type grounding connector
CBN (for telecom installation) or Earth Ground
Page 28
28
CPSMC19xx-100 PointSystem™Chassis
chassis
4.2 Cascade Option
The management module cascade option allows the network administrator to con­nect up to eight (8) CPSMC19xx-100 chassis into one manageable stack, providing a single management source for up to 143 conversion devices.
To create the cascade option, the CPSMM-200 Dual Slot Master Management Module is installed in the first chassis in the series. The CPSMM-210 Single-Slot Expansion management module is installed in each subsequent chassis.
An alternative setup involves installing two CPSMM-200 Dual-Slot Master Management Modules into two adjacent chassis for redundant management.
In this set-up, the two CPSMM-200 management modules auto-negotiate so that one is the primary module while the other is in stand-by mode. If the primary module fails, the stand-by module automatically takes over and manages the net­work.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
The CPSMM-200
management module is
installed in the first
chassis in the series
10BASE-T
PWR
TX
RX
LNK
RESET
DB-9
The CPSMM-210
management module is
installed in each
subsequent chassis
The CPSMM-200
management module is
installed in the first
chassis in the series
RESET
Pwr
RESET
Pwr
INIT
PWR
TX
10BASE-T
RX
LNK
RESET
DB-9
PWR
TX
Another CPSMM-200
managment module is
10BASE-T
RX
LNK
RESET
installed in the next
chassis as a backup
DB-9
Page 29
29
CPSMC19xx-100 PointSystem™Chassis
chassis
Cascading multiple CPSMC19xx-100 chassis
To cascade two or more CPSMC19xx-100 chassis:
1. Locate one (1) Transition Networks management module cascade cable (with
RJ-45 connectors installed at both ends) (P/N 6026) for each set of two (2) chassis to be cascaded.
NOTE: Transition Networks management module cascade cables are one (1) meter long. Ensure that the chassis are installed within one (1) meter of each other.
2. At the first chassis in the series: Plug the RJ-45 connector at one end of the cas-
cade cable into the management module’s RJ-45 port labeled “OUT”.
3. At the next chassis in the series: Plug the RJ-45 connector at the other end of the
cascade cable into the management module’s RJ-45 port labeled “IN”.
4. At the same chassis as in step 3: Plug the RJ-45 connector at one end of the cas-
cade cable into the management module’s RJ-45 port labeled “OUT”.
5. At the next chassis in the series: Plug the RJ-45 connector at the other end of the
cascade cable into the management module’s RJ-45 port labeled “IN”.
6. Repeat steps 4 and 5 until all chassis have been connected.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 30
30
CPSMC19xx-100 PointSystem™Chassis
chassis
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
4.3 Connecting the Slide-in-Modules to the Network
Once the CPSMC19xx-100 chassis has been installed, the media converter slide-in­modules may be connected to the network.
CAUTION: Connect input/output network cables ONLY to media converter slide­in-module connectors within the same network protocol (such as Ethernet-to-
Ethernet, Fast Ethernet-to-Fast Ethernet, ATM-to-ATM). Failure to observe this cau­tion will cause data transfer to fail.
Refer to user’s guides included with the media converter slide-in-modules for cabling specifications and instructions.
4.4 Operation
Daily operation of the CPSMC19xx-100 chassis requires no network administrator activity except for the occasional monitoring of the status LED indicators on the chassis and on the installed media converter slide-In-modules.
Each media converter slide-in-module and each management module has one or more LED indicators to help monitor the CPSMC19xx-100 chassis network.
Refer to the user’s guide included with each management module and slide-in­module to interpret the LED indicators.
PWR
TX
10BASE-T
RX
LNK
RESET
DB-9
RXF
RXC
TX
10BASE-FL
RX
10BASE-T
LKF
CETTF100
PWR
LKS
LKS
PWR
LKM
LKM
LKC
TX
TX
Singlemode
Singlemode
RX
RX
TX
TX
Multimode
Multimode
RX
RX
CFMFF100
CFMFF100
PWR
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
TX
RX
SPD
FRX
CRX
100BASE-FX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Check the individual user's guide for specific information on
how to connect each slide-in-module to the network.
PWR
TX
RX
RESET
MCCM10
MGMT MASTER
DB-9
LNK
DB-9
RXF
RXC
TX
10BASE-FL
RX
10BASE-T
LKF
CETTF100
LKM
LKM
LKC
TX
TX
Singlemode
Singlemode
RX
RX
TX
TX
Multimode
Multimode
RX
RX
CFMFF100
CFMFF100
PWR
PWR
LKS
LKS
PWR
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
E
10BASE-FL
0
10BASE-2
CETCF100
PWR
PWR
LKS
LNK
LKM
COL
TX
Link Alert
Singlemode
D
RX
TX
Multimode
50½
RX
CFMFF100
LED indicators on the management module and slide-in-modules
TX
RX
SPD
FRX
CRX
100BASE-FX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Page 31
31
CPSMC19xx-100 PointSystem™Chassis
network mgmt.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
5 Network Management
The CPSMM100 firmware and the FocalPoint™ application are described in the FocalPoint™ 2.0 Management Application and CPSMM100 Firmware user’s guide (P/N 33293). This manual is included on the application CD and is also available on-line at www.transition.com.
Transition Networks CPSMM100 firmware is embedded in the optional manage­ment modules (see section 2.2). The firmware allows the network administrator to configure and manage the CPSMC19xx-100 chassis from an attached terminal or from a remote, networked computer.
The firmware includes the Transition Networks Command Line Interface (CLI), a tel- net server, a Web browser, and an SNMP (Simple Network Management Protocol) agent.
In addition, Transition Networks FocalPoint™ application can be installed in the networked computer to provide a graphical user interface to monitor the PointSystem™ chassis.
Hardware Connections
Network management can be implemented either through the DB-9 serial port or through the RJ-45 Ethernet port of the management modules.
0
10BASE-T
IN
OUT
CPSMM200
PWR
TX
RX
LNK
RESET
RJ-45 Ethernet Port
DB-9
DB-9 Serial Port
10BASE-T
SERIAL
TX
RX
CPSMM120
PWR
LNK
RESET
CPSMM-200 CPSMM-12
Page 32
32
CPSMC19xx-100 PointSystem™Chassis
network mgmt.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
DB-9 Serial Port
The DB-9 serial port allows the network administrator to configure and manage the CPSMC19xx-100 chassis using the SNMP Command-Line Interface (CLI) at an attached terminal or terminal emulator.
Use a null modem cable to attach a terminal to the DB-9 serial port on the manage­ment module as shown.
RJ-45 Ethernet Port
The RJ-45 Ethernet port allows the network administrator to manage the CPSMC19xx-100 chassis via a remote Network Management Station (NMS) in one of two ways:
1. Using the Transition Networks FocalPoint™ graphical user interface.
2. Using a remote Telnet connection.
Use an RJ-45 network cable to attach a terminal (via a network hub or switch) to the RJ-45 Ethernet port on the management module as shown.
NOTE: To manage the PointSystem™ chassis via a remote NMS, both the RJ-45 Ethernet port and the NMS must be connected to a network with Internet access.
r
PWR
TX
10BASE-T
DB-9
RX
LNK
RESET
DB-9
RXF
RXC
TX
RX
10BASE-T
10BASE-FL
CETTF100
PWR
LKS
LKS
PWR
LKF
LKM
LKM
LKC
TX
TX
Singlemode
Singlemode
RX
RX
TX
TX
Multimode
Multimode
RX
RX
CFMFF100
CFMFF100
PWR
LA
RXF
RXC
10BASE-T
10BASE-2
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
E
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Attached terminal or terminal emulato connected to the DB-9 serial port via a
null modem cable
.
Network hub or switch connected to the RJ-45 Ethernet port.
PWR
PWR
TX
10BASE-T
DB-9
RX
LNK
RESET
DB-9
RXF
RXC
TX
RX
10BASE-T
10BASE-FL
CETTF100
PWR
LKS
LKS
PWR
LKF
LKM
LKM
LKC
TX
TX
Singlemode
Singlemode
RX
RX
TX
TX
Multimode
Multimode
RX
RX
CFMFF100
CFMFF100
Remote NMS with an SNMP application
PWR
PWR
SPD
LKS
LA
LNK
LKM
RXF
RXC
10BASE-T
10BASE-2
0
CECF100
CRX
COL
TX
Link Alert
Singlemode
E
D
TX
RX
TX
RX
Multimode
50½
RX
CFMFF100
Remote Telnet connection OR
PWR
PWR
LKS
FLNK
FRX
10/100SX
10/100TX
CFETF110
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
RX
Multimode
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Page 33
33
CPSMC19xx-100 PointSystem™Chassis
troubleshooting
6 Troubleshooting
1. Are any of the power LEDs on any of the slide-in-modules illuminated, AND are
the fans operating? YES
The chassis is receiving power. Proceed to the next step.
NO
Check all power supply cables for proper connection.
For AC power: Ensure the AC receptacle on the wall is supplying power.
If the fuse for the AC receptacle on the wall blows repeatedly, have the AC receptacle inspected by a qualified electrician.
For DC power: Ensure the DC power supply is supplying power.
Check the fans to see if they are operating.
Contact Technical Support: U.S./Canada: 1-800-260-1312, International: 00-1-952-941-7600.
2. For the management modules (CPSMM-120, CPSMM-200, CPSMM-210), are ANY of the power LEDs NOT illuminated? NO
All management modules are receiving power. Proceed to the next step.
YES
For those management modules where the power LED is NOT illuminated:
Ensure the management module is firmly seated in the slot.
Press the RESET button on the management module.
Contact Technical Support: U.S./Canada: 1-800-260-1312, International:
00-1-952-941-7600.
3. For the remaining slide-in-modules, are ANY of the power LEDs NOT illuminat­ed? NO
All slide-in-modules are receiving power. Proceed to the next step.
YES
For those slide-in-modules where the power LED is NOT illuminated:
Ensure the slide-in-module is firmly seated in the slot.
Contact Technical Support: U.S./Canada: 1-800-260-1312, International:
00-1-952-941-7600.
4. To determine if a fault is due to a software problem, consult the troubleshoot­ing section of the FocalPoint™ 2.0 Management Application and CPSMM100
Firmware User’s Guide (P/N 33293). This manual is available on the enclosed application CD and on-line at www.transition.com.
5. To determine if a fault is due to an individual management module or slide-in­module, consult the troubleshooting section of the user’s guide for that particu­lar module.
6. If none of the solutions listed in this section resolves the problem, contact Technical Support: U.S./Canada: 1-800-260-1312, International: 00-1-952­941-7600.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 34
34
CPSMC19xx-100 PointSystem™Chassis
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model CPSMC19xx-100 or equivalent.
Dimensions 17 x 14.3 x 3.5 inches (430 x 363 x 89 mm)
Weight 17.5 lbs. (8.0 kg)
MTBF (Mean Time Before Failure) MIL217F2 V5.0 (hrs) Bellcore7 V5.0 (hrs)
CPSMC1900 + CPSMP-200 79,071 206,816 CPSMC1900 + CPSMP-210 201,643 479,742
CPSMP-200
Power Input: 100-240 V, 50/60 Hz, 0.62 - 1.5 Amp (typical with a fully-loaded chassis) Power Output: +12 VDC at 10.83 Amp maximum.
CPSMP-210
Power Input: 48-VDC (38 - 58 VDC) @ 4.0 Amp (typical with a fully-loaded chassis) Power Output: +12 VDC at 12.5 Amp maximum.
Environment
Tmra*: 0 to 50°C (32 to 122°F) (*Manufacturer’s rated ambient temperature)
0 to 60°C (32 to 140°F) (when redundant power or fan module is used) Storage Temperature: -40 to 80°C (-40 to 176°F) Humidity 5 to 95%, non condensing Altitude 0 to 10,000 feet
Compliance EN 55022:1998+A1:2000 Class A; EN 55024:1998; UL Listed;
FCC Part 15 Subpart B; CE Mark; 21 CFR Subpart J
Warranty Lifetime
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC-825/CDRH standards and complies with 21 CFR1040.10 and 21CFR1040.11.
CAUTION: Visible and Invisible Laser Radiation When Open. Do Not Stare Into Beam Or View Directly
With Optical Instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein
may result in hazardous radiation exposure.
Page 35
35
CPSMC19xx-100 PointSystem™Chassis
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Cable Specifications
Null Modem Cable
The Null Modem Cable is used for connecting a terminal or terminal emulator to the management module’s DB-9 connector to access the command-line interface.
The table below shows the pin assignments for the DB9 cable.
Function Mnemonic Pin
Carrier Detect CD 1 Receive Data RXD 2 Transmit Data TXD 3 Data Terminal Ready DTR 4 Signal Ground GND 5 Data Set Ready DSR 6 Request To Send RTS 7 Clear To Send CTS 8
The table below shows the pin assignments for the RS-232 Null Modem cable:
RJ-45 Cable
Category 5:
Gauge: 24 to 22 AWG Attenuation: 22.0 dB /100m @ 100 MHz Maximum Cable Distance: 100 meters
• Straight-through OR crossover cable may be used.
• Shielded twisted-pair (STP) OR unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network. (RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-)
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a Gigabit Ethernet network.
• Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Page 36
36
CPSMC19xx-100 PointSystem™ Chassis
COAX Cable
Coaxial cable media is used for circuits such as DS3, E1 and 10Base-2 Ethernet. The impedance of the coaxial cable is determined by the interface type, for exam­ple:
75 ohm for DS3.
50 ohm for 10Base-2 Ethernet.
Special attention should be given to the grounding requirements of coaxial cable circuits. Installation may require grounding at both cable ends or only one cable end or neither cable end.
Cable Shield Grounding
Media converter network cabling my be shielded or unshielded. Shielded cables MUST be grounded according to the specific requirements of the media and port type. For example:
Shielded RJ-45 cable used for 100Base-Tx Ethernet MUST be grounded at both
cable endpoints via shielded RJ-45 jacks.
Shielded RS-232 cable MUST have the shield grounded at both cable endpoints
via shielded RS-232 connectors.
COAX cable used for 10Base-2 Ethernet MUST only be grounded at a single
point.
The media converters provide a jumper option or other grounding mechanism as required. Special attention should be given to the grounding requirements of coax­ial cable circuits. Installation may require grounding at both cable ends or only one cable end or neither cable end. See the individual media converter user’s guide for cable/port grounding requirements.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 37
37
CPSMC19xx-100 PointSystem™Chassis
Contact Us
Technical Support
Technical support is available 24 hours a day:
United States: 1-800-260-1312
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with a Transition Networks Technical Support Specialist.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides 12-16 seminars per month via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail message to our technical support staff.
techsupport@transition.com
Address
Transition Networks
6475 City West Parkway Minneapolis, MN 55344, USA
telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: PointSystem
Chassis
Part Number: CPSMC1900-100, CPSMC1910-100 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
PointSystem™Chassis
to which this declaration refers is in con-
formity with the following standards. EN 55022:1998+A1:2000 Class A; FCC Part 15 Subpart B; UL 1950; 21 CFR Subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
September 14, 2001
Stephen Anderson, Vice-President of Engineering Date
Page 38
38
CPSMC19xx-100 PointSystem™Chassis
Warranty
Limited Lifetime Warranty
Effective for products shipped May 1, 1999 and after. Every Transition Networks' labeled product purchased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. This warranty covers the original user only and is not transferable.
This warranty does not cover damage from accident, acts of God, neglect, contam­ination, misuse or abnormal conditions of operation or handling, including over­voltage failures caused by use outside of the product's specified rating, or normal wear and tear of mechanical components. If the user is unsure about the proper means of installing or using the equipment, contact Transition Networks' free tech­nical support services.
To establish original ownership and provide date of purchase, please complete and return the registration card accompanying the product or register the product on­line on our product registration page.
Transition Networks will, at its option:
Repair the defective product to functional specification at no charge,
Replace the product with an equivalent functional product, or
Refund the purchase price of a defective product.
To return a defective product for warranty coverage, contact Transition Networks' technical support department for a return authorization number. Transition's tech­nical support department can be reached through any of the following means:
Technical Support is available 24 hours a day at:
800-260-1312 x 200 or 952-941-7600 x 200
fax 952-941-2322
email techsupport@transition.com
live web chat: www.transition.com and click the “Transition Now” link
voice mail 800-260-1312 x 579 or 952-941-7600 x 579
All messages will be answered within one hour.
Send the defective product postage and insurance prepaid to the following address:
CSI Material Management Center c/o Transition Networks 508 Industrial Drive Waconia, MN 55387 USA Attn: RETURNS DEPT: CRA/RMA # ___________
Failure to properly protect the product during shipping may void this warranty. The return authorization number must be written on the outside of the carton to ensure its acceptance. We cannot accept delivery of any equipment that is sent to us with-
out a CRA or RMA number.
The customer must pay for the non-compliant product(s) return transportation costs to Transition Networks for evaluation of said product(s) for repair or replacement. Transition Networks will pay for the shipping of the repaired or replaced in-warran­ty product(s) back to the customer (any and all customs charges, tariffs, or/and taxes are the customer's responsibility).
Page 39
39
CPSMC19xx-100 PointSystem™Chassis
Before making any non-warranty repair, Transition Networks requires a $200.00 charge plus actual shipping costs to and from the customer. If the repair is greater than $200.00, an estimate is issued to the customer for authorization of repair. If no authorization is obtained, or the product is deemed not repairable, Transition Networks will retain the $200.00 service charge and return the product to the cus­tomer not repaired. Non-warranted products that are repaired by Transition Networks for a fee will carry a 180-day limited warranty. All warranty claims are subject to the restrictions and conventions set forth by this document.
Transition Networks reserves the right to charge for all testing and shipping incurred, if after testing, a return is classified as "No Problem Found."
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. TRAN­SITION NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON TRANSITION NET­WORKS' BEHALF.
Page 40
40
CPSMC19xx-100 PointSystem™ Chassis