Transition Networks PointSystem CPSMC1320-100, PointSystem CPSMC1300-100, PointSystem CPSMC1310-100 User Manual

Page 1
Transition Networks
CPSMC13xx-100
13-Slot PointSystem™ Chassis
User’s Guide
Revision D
CPSMC1300-100 CPSMC1310-100 CPSMC1320-100
Page 2
2
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Compliance Information
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2001-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from Transition Networks.
Printed in the U.S.A.
33208.D
Page 3
3
Table of Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.1 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1.2 Unpacking the CPSMC13xx-100 Equipment . . . . . . . . . . . . . . . . . . . . . .5
2 Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.1 Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.1.1 Chassis Face Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.1.2 Calculating Power Consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
2.1.3 Installing Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . .7
2.1.4 Replacing Media Converter Slide-in-Modules . . . . . . . . . . . . . . . . . . . . .8
2.2 Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.2.1 Three Types of Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . .9
2.2.2 Installing the Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .10
2.2.3 Replacing the Management Modules . . . . . . . . . . . . . . . . . . . . . . . . . .11
3 Powering the CPSMC13xx-100 . . . . . . . . . . . . . . . . . . . . . . .12
3.1 CPSMP-120 Power Supply Module (AC) . . . . . . . . . . . . . . . . . . . . . . . .12
3.2 CPSMP-130 Power Supply Module (48-VDC) . . . . . . . . . . . . . . . . . . . .14
3.3 CPSMP-140 Power Supply Module (24-VDC) . . . . . . . . . . . . . . . . . . . .16
3.4 Optional Dual Power Supply Modules . . . . . . . . . . . . . . . . . . . . . . . . . .18
3.5 Power Supply Module Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3.5.1 Installing the Power Supply Module . . . . . . . . . . . . . . . . . . . . . . . . . . .19
3.5.2 Replacing the Power Supply Module . . . . . . . . . . . . . . . . . . . . . . . . . .20
3.5.3 Replacing the Power Supply Fuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
4 CPSMC13xx-100 Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4.1 Installing the CPSMC13xx-100 Chassis . . . . . . . . . . . . . . . . . . . . . . . . .23
4.1.1 Table Top Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4.1.2 Standard 19-inch Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
4.1.3 Grounding Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
4.2 Cascade Option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
4.3 Connecting the Slide-in-Modules to the Network . . . . . . . . . . . . . . . . .28
4.4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
5 Network Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
5.1 Hardware Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Cable Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 4
4
introduction
1 Introduction
1.1 Description
The Transition Networks CPSMC13xx-100 13-Slot PointSystem™ chassis is a 19­inch, rack-mountable chassis for selected Transition Networks media converter slide-in-modules. The CPSMC13xx-100 chassis allows the network administrator to connect various copper and fiber-optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3, and OC-12 and many others. The chassis provides installation space for up to 13 single-slot media converter slide-in-modules in the front of the unit.
The CPSMC13xx-100 also comes equipped with an AC or DC power supply installed in the front of the chassis. An extra installation space is available for an optional redundant AC or DC power supply.
With installed PointSystem™ management module(s) (P/N CPSMM-120, -200, or
-210), the CPSMC13xx-100 can be managed and monitored via:
An SNMP application such as Transition Networks FocalPoint™ management software installed at a remote Network Management Station (NMS).
A remote Web browser.
A command-line interface (CLI) at an attached terminal.
A command-line-interface (CLI) at a remote Telnet connection.
The management modules also make it possible to control up to eight (8) cascaded chassis fully populated with installed media converter slide-in-modules.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
p
I
0
Power Supply Module
(AC module is pictured)
Management
Module
TX
RX
R E S E T
10BASE-T
SERIAL
CPSMM120
Extra Installation
S
ace
Installed
Slide-in-Module Open Slot
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
LNK
INIT
TERM
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Page 5
5
introduction
1.2 Unpacking the CPSMC13xx-100 Equipment
Use the following list to verify the shipment:
Item Part Number
13-Slot chassis with AC Power Supply CPSMC1300-100
13-Slot chassis with 48-VDC Power Supply CPSMC1310-100
13-Slot chassis with 24-VDC Power Supply CPSMC1320-100
PointSystem™ chassis face plates (10) CPSFP-200
Power Cord (varies by country)
User’s Guide 33208
The following items are optional accessories for the CPSMC13xx-100 13-Slot PointSystem™ chassis:
Item Part Number
Redundant AC Power Supply 120/240 VAC CPSMP-120 (optional)
Redundant 48-VDC Power Supply CPSMP-130 (optional)
Redundant 24-VDC Power Supply CPSMP-140 (optional)
Single-Slot Master Management Module CPSMM-120 (optional)
Dual-Slot Master Management Module CPSMM-200 (optional)
FocalPoint™ Software Disk 7223 (included with the Master Management Modules)
Expansion Management Module CPSMM-210 (optional)
Management Module Cascade Connector 6026 (optional)
23-inch Rack Mount Ears CPSRE-230 (optional)
Selectable Media Converter Slide-in-Module(s) (various P/N) - (optional)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 6
6
CPSMC13xx-100 PointSystem™Chassis
slide-in-modules
2 Slide-in-Modules
2.1 Media Converter Slide-in-Modules
Transition Networks media converter slide-in-modules, installed in slots at the front of the chassis, allow the network administrator to connect various copper and fiber­optic network media over protocols that include Ethernet, Fast Ethernet, DS3/E3, and OC-12 as well as many others (see www.transition.com for a complete listing).
NOTE: Refer to the specific user’s guide that comes with each media converter slide-in-module for cable, connector, and LED indicator information.
2.1.1 Chassis Face Plates
CAUTION: Slots in the CPSMC13xx-100 chassis without a slide-in-module installed MUST have a protective chassis face plate (P/N CPSFP-200) covering the empty slot for Class A compliance.
Install a chassis face plate over any unused chassis slot by aligning the hole in the face plate with the threaded hole in the chassis. Secure the face place with the enclosed bolt.
2.1.2 Calculating the Power Consumption
CAUTION: Before installing the media converter, refer to the power consumption
data for each individual media converter (provided in the user’s guide shipped with each media converter). The combined power consumption of all devices must not exceed the available power supply. Failure to observe this caution could result in diminishing system reliability.
In other words, the combined power requirements of the CPSMC13xx-100 chassis plus all slide-in-modules must be less than the available power.
In addition, the maximum power delivery capacity for each chassis slot is 12 Watts, with an aggregate chassis maximum of 6 Watts per slot. For example, a 12-Watt slide-in-module media converter would require the power of two slots. Therefore, only six (6) 12-Watt converters could be installed into the CPSMC13xx-100 chassis. Six (6) slots must remain unused and the remaining slot can accommodate a slide­in-module up to 6 Watts.
Contact Transition Networks Tech Support to ensure the power requirements for your specific application do not exceed the available power.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I
0
Chassis Face Plate
Page 7
7
CPSMC13xx-100 PointSystem™Chassis
slide-in-modules
2.1.3 Installing the Media Converter Slide-in-Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the slide-in-module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the slide-in-module(s).
NOTE: The slide-in-modules can be installed in any installation slot, in any order.
To install the slide-in-module into the CPSMC13xx-100 chassis:
1. If a chassis face plate (P/N CPSFP-200) is covering the installation slot, remove the face plate from the installation slot by removing the one (1) screw that secures the plate to the front of the chassis.
NOTE: If the slide-in-module requires two slots, remove the face plates from two (2) adjacent installation slots.
2. Align the slide-in-module with the chassis installation slot so that the panel fastener screw is at the top of the module.
3. Carefully slide the slide-in-module into the installation slot, while aligning the module’s circuit board with the installation guides.
NOTE: Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the slide-in-module to the chassis.
5. Repeat steps 1 through 4 for any additional slide-in-module(s).
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
w
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
TX
RX
LNK
R E S E
I
0
I
0
T
10BASE-T
SERIAL
CPSMM120
INIT
TERM
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
TX
Singlemode
Singlemode
LKF
RXF
RX
RX
PWR
LKC
RXC
TX
TX
Multimode
Multimode
TX
10BASE-FL
RX
RX
CFMFF100
CFMFF100
RX
10BASE-T
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Panel Fastener Scre
Page 8
8
CPSMC13xx-100 PointSystem™Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.1.4 Replacing the Media Converter Slide-in-Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing the slide-in-module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the slide-in-module(s).
NOTE: The media converter slide-in-modules can be hot-swapped.
To replace a media converter slide-in-module:
1. Remove the slide-in-module to be replaced by loosening the panel fastener screw that secures it to the chassis front. Slide the module from the chassis.
2. Align the replacement slide-in-module with the chassis installation slot so that the panel fastener screw is at the top.
3. Carefully slide the replacement slide-in-module into the installation slot, while aligning the module’s circuit board with the installation guides.
NOTE: Ensure that the slide-in-module is firmly seated inside the chassis.
4. Rotate the attached panel fastener screw clockwise to secure the slide-in­module to the chassis.
w
LA
RXF
RXC
10BASE-T
10BASE-2
E
0
CECF100
PWR
PWR
SPD
LKS
LNK
FRX
LKM
CRX
COL
TX
Link Alert
Singlemode
D
TX
10/100SX
RX
TX
RX
Multimode
50½
10/100TX
RX
CFMFF100
CFETF110
PWR
TX
RX
LNK
R E S E
I
0
I
0
T
10BASE-T
SERIAL
CPSMM120
INIT
TERM
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
TX
Singlemode
Singlemode
LKF
RXF
RX
RX
PWR
LKC
RXC
TX
TX
Multimode
Multimode
TX
10BASE-FL
RX
RX
CFMFF100
CFMFF100
RX
10BASE-T
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Panel Fastener Scre
Page 9
9
CPSMC13xx-100 PointSystem™Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.2 Management Modules
Optional network management is provided by SNMP software embedded in Transition Networks
PointSystem
management module(s) that can be installed in
the CPSMC13xx-100 chassis.
Transition Networks provides two such modules:
CPSMM-120 Single-Slot Master Management Module.
CPSMM-200 Dual-Slot Master Management Module.
Along with an additional expansion module:
CPSMM-210 Single Slot Expansion Management Module.
2.2.1 Three Types of Management Modules
CPSMM-120 Single-Slot Master Management Module
The optional CPSMM-120 Single-Slot Master Management Module can be installed to enable network management of a single CPSMC13xx­100 chassis.
Refer to the CPSMM-120 user’s guide for more information on the CPSMM-120 Single-Slot Master Management Module.
CPSMM-200 Dual-Slot Master Management Module
The optional CPSMM-200 Dual-Slot Master Management Module can also be installed in the CPSMC13xx-100 chassis to enable network management.
This module has all of the features of the CPSMM-120 plus a pair of cascade ports, which allow multiple PointSystem™ chassis to be connected.
Note also that this module requires two adjacent slots in the chassis for installation.
Refer to the CPSMM-200/-210 user’s guide for more information on the CPSMM-200 Dual-Slot Master Management Module.
CPSMM-210 Single-Slot Expansion Management Module
The CPSMM-210 is used with the CPSMM-200 to connect up to eight (8) PointSystem™ chassis into one manageable stack.
Refer to the CPSMM-200/-210 user’s guide for more information on the CPSMM-210 Single-Slot Expansion Management Module.
NOTE: See section 4.2 Cascade Option for details on connecting multiple chassis.
10BASE-T
SERIAL
CPSMM120
PWR
TX
RX
LNK
RESET
10BASE-T
IN
OUT
CPSMM200
Power
IN
OUT
PWR
TX
RX
LNK
RESET
RESET
CPSMM210
DB-9
Page 10
10
CPSMC13xx-100 PointSystem™Chassis
slide-in-modules
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
2.2.2 Installing the Management Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the management module into the CPSMC13xx-100 chassis. Failure to observe this caution could result in damage to, and subsequent failure of, the management module.
NOTE: Transition Networks recommends installing the management module into
the left-most installation slot to keep the management module cables separate from the media converter cables.
To install a management module into the CPSMC13xx-100 chassis:
1a. CPSMM-200 Dual-Slot Master Management Module:
If chassis face plates are covering the installation slots, remove the face plates from the two (2) installation slots at the far-left position of the chassis.
1b. CPSMM-120 Single-Slot Master Management Module OR
CPSMM-210 Single-Slot Expansion Management Module:
If chassis face plates are covering the installation slots, remove the face plate from the one (1) installation slot at the far-left position of the chassis.
2. Align the management module with the chassis installation slot so that the panel fastener screw is at the top of the module.
3. Carefully slide the management module into the installation slot, while aligning the module’s circuit board with the installation guides.
NOTE: Ensure that management module is firmly seated inside the chassis.
4. Rotate the attached panel fastener screw clockwise to secure the management module to the chassis.
PWR
TX
RX
LNK
R E S E
I
0
I
0
T
10BASE-T
SERIAL
CPSMM120
INIT
TERM
MCCM10
MGMT MASTER
PWR
TX
RX
LNK
RESET
INIT
12C
12C-1TERM
DB-9
DB-9
Panel Fastener Screw
PWR
TX
RX
LNK
R E S E
I
0
I
0
T
10BASE-T
SERIAL
CPSMM120
INIT
TERM
PWR
TX
RX
LNK
RESET
Panel Fastener Screw
Page 11
11
CPSMC13xx-100 PointSystem™Chassis
slide-in-modules
2.2.3 Replacing the Management Modules
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing the management module(s). Failure to observe this caution could result in damage to, and subsequent failure of, the management module(s).
NOTE: The management modules can be replaced while the chassis remains powered. However, you must configure a new IP address for the replacement management module. For more information, see the FocalPoint™ 2.0 user’s guide
on the enclosed application CD or on-line at www.transition.com.
To replace a management module in the CPSMC13xx-100 chassis:
1. Remove the management module to be replaced by loosening the panel fastener screw that secures the module to the chassis front. Slide the module
from the chassis.
2. Align the replacement module with the installation slot so that the panel fastener screw is at the top.
3. Carefully slide the replacement management module into the installation slot, while aligning the module’s circuit board with the installation guides.
NOTE: Ensure that the management module is firmly seated inside the chassis.
4. Rotate the attached panel fastener screw clockwise to secure the module to the chassis.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
PWR
TX
RX
LNK
R E S E
I
0
I
0
T
10BASE-T
SERIAL
CPSMM120
INIT
TERM
MCCM10
MGMT MASTER
PWR
TX
RX
LNK
RESET
INIT
12C
12C-1TERM
DB-9
DB-9
Panel Fastener Screw
Page 12
12
CPSMC13xx-100 PointSystem™Chassis
power supply
3 Powering the CPSMC13xx-100
3.1 CPSMP-120 Power Supply Module (AC)
The CPSMC1300-100 PointSystem™ chassis is equipped with an AC power supply module (P/N CPSMP-120) installed in the front of the chassis. The power supply module supplies power to the chassis, installed media converter slide-in-modules, and management modules.
The components of the CPSMP-120 AC power supply module include:
An AC power cord that distributes power from an external outlet to an AC power connector on the power supply module.
An On/Off switch that, when set to “I”, allows the module to supply power to the chassis and any installed modules.
•A power LED indicator.
An fuse installed in a fuse holder.
Optional Redundant AC Power Supply Module
An extra installation space is available in the front of the chassis for installing an optional redundant AC power supply module (P/N CPSMP-120). See section 3.5.1 Installing the Power Supply Module for instructions on installation.
Instant Fail-Over
The Instant Fail-Over feature ensures uninterrupted power to the chassis. If one of the power supply modules loses power, the chassis mother board automatically switches to the other power supply.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I
0
I
0
On/Off Switch
Fuse Holder
AC Power Connector
Power LED
Redundant Power Supply Installation Space
AC Power Cord
Page 13
13
power supply
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Powering the AC Power Supply Module
To power the CPSMC1300-100 chassis through the CPSMP-120 AC power supply module:
1. Set the On/Off switch to “0”.
2. Connect the female end of power cord to the power receptacle on the power supply module.
3. Plug the end of the power cord into the correct voltage AC rack or wall socket.
4. Set the On/Off switch to “I”.
5. Verify that the chassis is powered by observing the illuminated power LED.
I
0
I
0
On/Off Switch
AC Power Connector
Power LED
AC Power Cord
Page 14
14
CPSMC13xx-100 PointSystem™Chassis
power supply
3.2 CPSMP-130 Power Supply Module (48-VDC)
The CPSMC1310-100 chassis is equipped with a 48-VDC power supply module (P/N CPSMP-130) installed in the front of the chassis. The power supply module supplies power to the chassis, installed media converter slide-in-modules, and management modules.
The components of the CPSMP-130 48-VDC power supply module include:
A set of three (3) external power connectors that distribute power from an external 48-VDC outlet to a chassis ground connector, a positive (+) connector, and a negative (-) connector on the power supply module.
An On/Off switch that, when set to “I”, allows the module to supply power to the chassis, and any installed modules.
•A power LED indicator.
•A fuse installed on the power supply module’s circuit board.
Optional Redundant 48-VDC Power Supply Module
An extra installation space is available in the front of the chassis for installing an optional redundant 48-VDC power supply module (P/N CPSMP-130). See section
3.5.1 Installing the Power Supply Module for instructions on installation.
Instant Fail-Over
The Instant Fail-Over feature ensures uninterrupted power to the chassis. If one of the power supply modules loses power, the chassis mother board automatically switches to the other power supply.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
On/Off Switch
Power LED
I 0
­+
Fuse (on the circuit board)
External Power Connectors
Redundant Power Supply Installation Space
Page 15
15
power supply
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Read and follow all warning notices & instructions marked on the product or included in the manual.
CAUTION: All installation and service must be performed by qualified service personnel.
CAUTION: Ensure that the external power source is NOT powered and that the On/Off switch is set to “0” when connecting the 48-VDC power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
Powering the 48-VDC Power Supply Module
This product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation requirements and local electrical codes. Prior to installation, use a voltmeter/ohmmeter to check the wiring for the presence of earth ground.
A readily accessible disconnect device as part of the building installation shall be incorporated into the fixed wiring. The disconnect device (a 48 VDC, 15 or 20A circuit breaker or switch) must be included in the ungrounded supply conductor. Overcurrent protection must be a 48 VDC, 15 or 20A fuse or circuit breaker.
To power the CPSMC1310-100 chassis through the CPSMP-130 48-VDC power supply module:
1. Set the On/Off switch to “0”.
2. Connect the +48-VDC terminal to the chassis external power connector marked “+”. Turn the terminal screw clockwise to secure.
3. Connect the -48-VDC terminal to the chassis external power connector marked “-”. Turn the terminal screw clockwise to secure.
4. Connect the ground terminal to the chassis external power connector marked “chassis ground”. Turn the terminal screw clockwise to secure.
5. Set the On/Off switch to “I”.
6. Verify that chassis is powered by observing the illuminated power LED.
On/Off
GND
+
Switch
0 I
-
+
External Power Connectors
0 I
-
+
Panel Fastener Screw
Power LED
Page 16
16
CPSMC13xx-100 PointSystem™Chassis
power supply
3.3 CPSMP-140 Power Supply Module (24-VDC)
The CPSMC1320-100 chassis is equipped with a 24-VDC power supply module (P/N CPSMP-140) installed in the front of the chassis. The power supply module supplies power to the chassis, installed media converter slide-in-modules, and management modules.
The components of the CPSMP-140 24-VDC power supply module include:
A set of three (3) external power connectors that distribute power from an external 24-VDC outlet to a chassis ground connector, a positive (+) connector, and a negative (-) connector on the power supply module.
An On/Off switch that, when set to “I”, allows the module to supply power to the chassis, and any installed modules.
•A power LED indicator.
•A fuse installed on the power supply module’s circuit board.
Optional Redundant 24-VDC Power Supply Module
An extra installation space is available in the front of the chassis for installing an optional redundant 24-VDC power supply module (P/N CPSMP-140). See section
3.5.1 Installing the Power Supply Module for instructions on installation.
Instant Fail-Over
The Instant Fail-Over feature ensures uninterrupted power to the chassis. If one of the power supply modules loses power, the chassis mother board automatically switches to the other power supply.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
On/Off Switch
Power LED
I 0
­+
Fuse (on the circuit board)
External Power Connectors
Redundant Power Supply Installation Space
Page 17
17
CPSMC13xx-100 PointSystem™Chassis
power supply
Read and follow all warning notices & instructions marked on the product or included in the manual.
CAUTION: All installation and service must be performed by qualified service personnel.
CAUTION: Ensure that the external power source is NOT powered and that the On/Off switch is set to “0” when connecting the 24-VDC power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
Powering the 24-VDC Power Supply Module
This product is intended to be used in a restricted access location. Proper earthing (grounding) is required to ensure safe operation. Grounding terminals are provided (section 4.1.3) for proper grounding of the device as per customer installation requirements and local electrical codes. Prior to installation, use a voltmeter/ohmmeter to check the wiring for the presence of earth ground.
A readily accessible disconnect device as part of the building installation shall be incorporated into the fixed wiring. The disconnect device (a 24 VDC, 15 or 20A circuit breaker or switch) must be included in the ungrounded supply conductor. Overcurrent protection must be a 24 VDC, 15 or 20A fuse or circuit breaker.
To power the CPSMC1320-100 chassis through the CPSMP-140 24-VDC power supply module:
1. Set the On/Off switch to “0”.
2. Connect the +24-VDC terminal to the chassis external power connector marked “+”. Turn the terminal screw clockwise to secure.
3. Connect the -24-VDC terminal to the chassis external power connector marked “-”. Turn the terminal screw clockwise to secure.
4. Connect the ground terminal to the chassis external power connector marked “chassis ground”. Turn the terminal screw clockwise to secure.
5. Set the On/Off switch to “I”.
6. Verify that chassis is powered by observing the illuminated power LED.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
On/Off
GND
– +
Switch
0 I
­+
External Power Connectors
0 I
-
+
Panel Fastener Screw
Power LED
Page 18
18
CPSMC13xx-100 PointSystem™Chassis
power supply
3.4 Optional Dual Power Supply modules
Alternatively, two different types of power supplies may be installed in any of the CPSMC13xx-100 chassis, where one power supply is the primary and the other is the back up.
The drawing above shows one AC power supply and one DC power supply. However, the CPSMC13xx-100 chassis can accommodate any combination of AC, 48-VDC and 24-VDC power supplies. See section 3.5 Power Supply Module Maintenance for instructions on installation.
Instant Fail-Over
The Instant Fail-Over feature ensures uninterrupted power to the chassis. If one of the power supply modules loses power, the chassis mother board automatically switches to the other power supply.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
AC Power Supply DC Power Supply
I 0
I
0
­+
Page 19
19
CPSMC13xx-100 PointSystem™Chassis
power supply
Warning: Do NOT connect the power supply module to the external power source before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
3.5 Power Supply Module Maintenance
3.5.1 Installing the Power Supply Module
The AC and DC modules are installed in the same manner:
1. Remove the power supply module protective plate from the installation slot by removing and retaining the screw that secures the protective plate to the front of the chassis.
2. Carefully slide the power supply module into the installation slot, aligning the power supply module with the installation guides.
3. Ensure that the power supply module is firmly seated inside the chassis. If the power supply module does not fit flush against the frame, remove the module and ensure that it is aligned with the installation guides before installing.
4. Rotate the attached panel fastener screw clockwise to secure the power supply module to the chassis.
5. Connect the power supply module to the external power source. (AC: see page 13 / 48-VDC: see page 15 / 24-VDC: see page 17.)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
0
I
0
I
0
I
Page 20
20
CPSMC13xx-100 PointSystem™Chassis
power supply
Warning: Do NOT connect the power supply module to the external power source before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
3.5.2 Replacing the Power Supply Module
NOTE: Any of the power supply modules may be “hot swapped” provided the module to be swapped has been disconnected from the external power source and the On/Off switch has been set to “0”.
The AC and DC modules are replaced in the same manner:
1. Set the On/Off switch on the power supply module to be replaced to “0”.
2. Disconnect the power supply module to be replaced from the external power
source.
2. Loosen the panel fastener screw that secures the power supply module to the chassis.
3. Slide the power supply module from the chassis.
4. Carefully slide the replacement power supply module into the installation slot, aligning the power supply module with the installation guides.
5. Ensure that the the power supply module is firmly seated against the back of the chassis. If the power supply module does not fit flush against the frame, remove the module and ensure that it is aligned with the installation guides before installing.
6. Rotate the attached panel fastener screw clockwise to secure the power supply module to the chassis.
7. Connect the power supply module to the external power source. (AC: see page 13 / 48-VDC: see page 15 / 24-VDC: see page 17.)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
0
I
0
I
Page 21
21
CPSMC13xx-100 PointSystem™Chassis
power supply
Warning: Do NOT connect the power supply module to the external power source before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
3.5.3 Replacing the Power Supply Fuse
Replacing the AC Fuse
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing the fuse in the power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
NOTE: Replace the fuse only with the same size and rating. Failure to observe this
caution could result in equipment damage.
1. Set the On/Off switch on the power supply module to “0”.
2. Disconnect the power supply module from the external power source.
3. From the inside edge of the power receptacle, insert a small flat blade screwdriver into the groove on the front, inside edge of the fuse holder and carefully pry the fuse holder from the power supply module.
4. Carefully remove the fuse from the fuse holder.
5. Install a same size and rating replacement fuse in the fuse holder.
6. Return the fuse holder and fuse to the installation position in the power supply module. Snap the fuse holder into place.
7. Connect the power supply module to the external power source (see page 13).
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I
0
Fuse Holder
Fuse
Page 22
22
CPSMC13xx-100 PointSystem™chassis
power supply
Warning: Do NOT connect the power supply module to the external power source before installing it into the chassis. Failure to observe this caution could result in equipment damage and/or personal injury or death.
Replacing the 48-VDC or 24-VDC Fuse
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when replacing the fuse in the power supply module. Failure to observe this caution could result in damage to, and subsequent failure of, the power supply module.
NOTE: Replace the fuse only with the same size and rating. Failure to observe this
caution could result in equipment damage.
1. Set the On/Off switch on the power supply module to “0”.
2. Disconnect the power supply module from the external power source.
3. Loosen the panel fastener screw that secures the module to the chassis.
4. Slide the module from the chassis and place it on a flat surface.
5. Remove the four (4) screws that secure the panel to the module (see drawing below) and remove the panel from module.
6. The fuse is located inside the power supply module on the circuit board. Remove the fuse from the fuse holder.
7. Install a same size and rating replacement fuse in the fuse holder.
8. Replace the panel to the power supply module and secure it in place with the four (4) screws.
9. Slide the power supply module into the installation slot, aligning the module with the installation guides. Ensure that the module is firmly seated inside the chassis.
10. Rotate the attached panel fastener screw clockwise to secure the power supply module to the chassis.
11. Connect the power supply module to the external power source. (48-VDC: see page 15 / 24-VDC: see page 17.)
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
+
+
+
+
0 I
­+
Fuse location
Remove these four (4) screws
to access the fuse
10BASE-2
Page 23
23
CPSMC13xx-100 PointSystem™Chassis
chassis
4 CPSMC13xx-100 Chassis
4.1 Installing the CPSMC13xx-100 Chassis
The CPSMC13xx-100 can be installed in a standard 19-inch rack or on a table, shelf, or other stable surface.
CAUTION: Install the chassis so that the air flow around it is not restricted.
4.1.1 Table-Top Installation
The CPSMC13xx-100 chassis is shipped with nine (9) rubber feet for optional installation on a table or other flat, stable surface in a well-ventilated area. If table­top installation is desired, remove the rubber feet from the card and place them on the bottom of the chassis. Distribute the feet evenly so that the chassis is level when placed upright.
4.1.2 Standard 19-inch Rack Installation
The maximum recommended ambient temperature (Tmra) for the CPSMC13xx-100 chassis is 50°C. If the chassis is installed in a closed or multi-unit rack assembly,
the operating ambient temperature of the the rack environment may be greater than room ambient.
NOTE: Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips).
The chassis is designed so that the installation brackets can be installed to align the chassis either flush against the front or back edge of the rack or recessed from the front or back edge of the rack.
Warning: Select mounting bracket locations on the chassis that will keep the chassis balanced when mounted in the rack. Failure to observe this warning could allow the chassis to fall, resulting in equipment damage and/or possible injury to personnel.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Flush Alignment
at front
Recessed Alignment
at front
Flush Alignment
at back
Recessed Alignment
at back
Page 24
24
CPSMC13xx-100 PointSystem™Chassis
chassis
To install the CPSMC13xx-100 chassis into a standard 19-inch rack:
1. Determine the preferred alignment of the chassis in the rack.
NOTE: Installation bracket mounting screws are provided. Rack mount screws and clip nuts are NOT provided.
2. Locate six (6) installation bracket mounting screws (provided) for each chassis to be installed.
Warning: Mount the chassis evenly and securely onto the rack. Failure to observe this warning could allow the chassis to fall, resulting in equipment damage and/or possible injury to personnel.
3. Align the universal mounting bracket in the selected position against the side of the chassis so that the chassis installation holes are visible through the universal bracket installation holes.
4. Using a Phillips screwdriver, install the three (3) screws through the mounting bracket into the installation holes on side of the chassis.
5. Repeat steps 3 and 4 for the second mounting bracket.
6. Locate four (4) screws (not provided) and optional clip-nuts (not provided) for each chassis to be installed.
7. Carefully align the chassis at a secure and level position between the 19-inch site rack mounting rails.
8. Install two (2) screws through the right bracket into the right mounting rail and two (2) screws through the left bracket into the left mounting rail, using the clip nuts to secure, if necessary.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
I
0
I
0
Page 25
25
CPSMC13xx-100 PointSystem™Chassis
chassis
4.1.3 Grounding Lugs
The CPSMC13xx-100 comes equipped with grounding lugs, which are provided for a grounding conductor wire terminated with a two-hole, compression-type, grounding connector. The grounding wire -- which must be a copper conductor -­is not included with the chassis and must be provided by the customer/installer.
The electrical conducting path from the chassis must:
Flow via the grounding lugs to the Common Bonding Network (CBN) for telecom installations; or to an alternate approved grounding system (if required) for non-telecom installations,
Be of sufficiently low impedance to conduct fault currents likely to be imposed on the chassis, and
Enable proper operation of any over-current protection devices.
The two-hole, compression-type, grounding connector must be fastened to the grounding lugs with the enclosed, anti-rotation star-washers and lug-nut fasteners. The required torque to the fasteners is specified by the connector’s manufacturer.
To properly ground the CPSMC13xx-100 chassis:
1. Obtain one (1) properly-terminated, grounding conductor (12 AWG copper wire gauge or larger) with a two-hole, compression-type, grounding connector. Note the manufacturer's applied torque that is required for the connector.
2. Attach the grounding conductor to the chassis by placing the two-hole, compression-type connector onto the grounding lugs and fasten with appropriate lock-washers and lug-nuts at the proper torque.
3. Attach the opposite end of the properly-terminated grounding conductor to the Common Bonding Network (CBN) for telecom installations, or to an approved grounding system (if required) for non-telecom installations.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
g
p
r
Grounding lugs
(6-32, 1/8" diam.)
3/4-inch
spacing
Two-hole, compression-type grounding connector (not included)
Star washer (included)
Lug nuts (included)
12 AWG copper wire
(not included)
Grounding Lugs
CBN (for telecom installation)
or earth
round
Grounding wire with a two-hole, com
ression-type grounding connecto
Page 26
26
CPSMC13xx-100 PointSystem™Chassis
chassis
4.2 Cascade Option
The management module cascade option allows the network administrator to connect up to eight (8) chassis into one manageable stack, providing a single management source for up to 95 conversion devices.
To create the cascade option, the CPSMM-200 Dual Slot Master management module is installed in the first chassis in the series. The CPSMM-210 Single-Slot Expansion Management Module is installed in each subsequent chassis.
An alternative setup involves installing two CPSMM-200 Dual-Slot Master Management Modules into two adjacent chassis for redundant management.
In this set-up, the two CPSMM-200 management modules auto-negotiate so that one module is the primary while the other is in stand-by mode. If the primary module fails, the stand-by module automatically takes over and manages the network.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
The CPSMM-200
management module is
installed in the first
chassis in the series
The CPSMM-210
management module is
installed in each
subsequent chassis
The CPSMM-200
management module is
installed in the first
chassis in the series
I 0
­+
I 0
­+
I 0
­+
PWR
TX
RX
LNK
RESET
Pwr
INIT
Pwr
I 0
­+
PWR
TX
RX
LNK
RESET
Another CPSMM-200
managment module is
installed in the next
chassis as a backup
I 0
­+
PWR
TX
RX
LNK
RESET
Page 27
27
CPSMC13xx-100 PointSystem™Chassis
chassis
Cascading multiple CPSMC13xx-100 chassis
To cascade two or more chassis:
1. Locate one (1) Transition Networks management module cascade cable (with RJ-45 connectors installed at both ends) (P/N 6026) for each set of two (2) chassis to be cascaded.
NOTE: Transition Networks management module cascade cables are one (1) meter long. Ensure that the chassis are installed within one (1) meter of each other.
2. At the first chassis in the series: Plug the RJ-45 connector at one end of the cascade cable into the management module’s RJ-45 port labeled “OUT”.
3. At the next chassis in the series: Plug the RJ-45 connector at the other end of the cascade cable into the management module’s RJ-45 port labeled “IN”.
4. At the same chassis as in step 3: Plug the RJ-45 connector at one end of the cascade cable into the management module’s RJ-45 port labeled “OUT”.
5. At the next chassis in the series: Plug the RJ-45 connector at the other end of the cascade cable into the management module’s RJ-45 port labeled “IN”.
6. Repeat steps 4 and 5 until all chassis have been connected.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 28
28
CPSMC13xx-100 PointSystem™Chassis
chassis
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
4.3 Connecting the Slide-in-Modules to the Network
Once the CPSMC13xx-100 chassis has been installed, the media converter slide-in­modules may be connected to the network.
CAUTION: Connect input/output network cables ONLY to media converter connectors within the same network protocol (such as Ethernet-to-Ethernet, Fast
Ethernet-to-Fast Ethernet, ATM-to-ATM). Failure to observe this caution will cause data transfer to fail.
Refer to the user’s guide included with each media converter slide-in-module for cabling specifications and instructions.
4.4 Operation
Daily operation of the CPSMC13xx-100 chassis requires no network administrator activity except for the occasional monitoring of the status LED indicators on the installed media converter slide-in-modules.
Each media converter and each management module has one or more LED indicators to help monitor the CPSMC13xx-100 chassis network.
Refer to the individual user’s guide included with each Transition Networks slide-in­module to interpret the LED indicators.
s
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
PWR
SPD
FRX
CRX
TX
10/100SX
RX
10/100TX
CFETF110
I 0
­+
PWR
TX
10BASE-T
RX
LNK
RESET
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
Check the individual user's guides for specific information on
how to connect each slide-in-module to the network.
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
I 0
-
+
PWR
TX
10BASE-T
RX
LNK
RESET
PWR
SPD
LKS
DB-9
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
FRX
CRX
TX
10/100SX
RX
10/100TX
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
10BASE-FL
10BASE-2
Link Alert
E
0
CETCF100
PWR
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
LED indicators on the management module and slide-in-module
Page 29
29
CPSMC13xx-100 PointSystem™Chassis
network mgmt
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
5 Network Management
The CPSMM100 firmware and the FocalPoint™ application are described in the FocalPoint™ 2.0 Management Application and CPSMM100 Firmware user’s guide (P/N 33293). This manual is included on the application CD and is also available on-line at www.transition.com.
Transition Networks CPSMM100 firmware is embedded in the optional management modules (see section 2.2). The firmware allows the network administrator to configure and manage the CPSMC13xx-100 chassis from an attached terminal or from a remote, networked computer.
The firmware includes the Transition Networks Command Line Interface (CLI), a telnet server, a Web browser, and an SNMP (Simple Network Management Protocol) agent.
In addition, Transition Networks FocalPoint™ application can be installed in the networked computer to provide a graphical user interface to monitor the PointSystem™ chassis.
5.1 Hardware Connections
Network Management can be implemented either through the DB-9 serial port or through the RJ-45 Ethernet port of the management modules.
0
PWR
TX
10BASE-T
RX
LNK
RESET
IN
OUT
CPSMM200
CPSMM-200 CPSMM-12
RJ-45 Ethernet Port
DB-9
DB-9 Serial Port
10BASE-T
SERIAL
TX
RX
CPSMM120
PWR
LNK
RESET
Page 30
30
CPSMC13xx-100 PointSystem™Chassis
network mgmt
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
DB-9 Serial Port
The DB-9 serial port allows the network administrator to configure and manage the CPSMC13xx-100 chassis using the SNMP Command-Line Interface (CLI) at an attached terminal or terminal emulator.
Use a null modem cable to attach a terminal to the DB-9 serial port on the management module as shown.
RJ-45 Ethernet Port
The RJ-45 Ethernet port allows the network administrator to manage the CPSMC13xx-100 chassis via a remote Network Management Station (NMS) in one of two ways:
1. Using the Transition Networks FocalPoint™ graphical user interface.
2. Using a remote Telnet connection.
Use an RJ-45 network cable to attach a terminal (via a network hub or switch) to the RJ-45 Ethernet port on the management module as shown.
NOTE: To manage the chassis via a remote NMS, both the RJ-45 Ethernet port and the NMS must be connected to a network with Internet access.
r
I 0
­+
PWR
TX
10BASE-T
RX
LNK
RESET
PWR
SPD
LKS
DB-9
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
FRX
CRX
TX
10/100SX
RX
10/100TX
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
LA
RXF
RXC
E
10BASE-FL
0
10BASE-2
CETCF100
PWR
PWR
LNK
COL
Link Alert
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
TX
RX
SPD
FRX
CRX
100BASE-FX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Attached terminal or terminal emulato connected to the DB-9 serial port via a
null modem cable
.
Network hub or switch connected to the
Remote Telnet connection
oR Remote NMS with
RJ-45 Ethernet port.
I 0
­+
PWR
TX
10BASE-T
RX
LNK
RESET
PWR
SPD
LKS
DB-9
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
FRX
CRX
TX
10/100SX
RX
10/100TX
CFETF110
PWR
PWR
LKS
FLNK
LKM
CLNK
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
an SNMP application
PWR
LA
RXF
RXC
E
10BASE-FL
0
10BASE-2
Link Alert
CETCF100
PWR
LNK
COL
D
50½
LKS
LKM
TX
Singlemode
RX
TX
Multimode
RX
CFMFF100
SPD
FRX
CRX
TX 100BASE-FX
RX
100BASE-TX
CFETF100
PWR
FLNK
CLNK
Page 31
31
CPSMC13xx-100 PointSystem™Chassis
troubleshooting
6 Troubleshooting
1. Are any of the POWER LEDs on any of the slide-in-modules illuminated? YES
The chassis is receiving power. Proceed to the next step.
NO
Check all power supply cables for proper connection.
For AC power: Ensure the AC receptacle on the wall is supplying power.
If the fuse for the AC receptacle on the wall blows repeatedly, have the AC
receptacle inspected by a qualified electrician.
For DC power: Ensure the DC power supply is supplying power.
Contact Technical Support: U.S./Canada: 1-800-260-1312, International:
00-1-952-941-7600.
2. For the management modules (CPSMM120, CPSMM200, CPSMM210), are ANY of the POWER LEDs NOT illuminated? NO
All management modules are receiving power. Proceed to the next step.
YES
For those management modules where the POWER LED is NOT illuminated:
Ensure the management module is firmly seated in the slot.
Press the RESET button on the management module.
Contact Technical Support: U.S./Canada: 1-800-260-1312, International:
00-1-952-941-7600.
3. For the remaining slide-in-modules, are ANY of the POWER LEDs NOT illuminated? NO
All slide-in-modules are receiving power. Proceed to the next step.
YES
For those slide-in-modules where the POWER LED is NOT illuminated:
Ensure the slide-in-module is firmly seated in the slot.
Contact Technical Support: U.S./Canada: 1-800-260-1312, International:
00-1-952-941-7600.
4. To determine if a fault is due to a software problem, consult the troubleshooting section of the FocalPoint™ 2.0 Management Application and
CPSMM100 Firmware User’s Guide (P/N 33293). This manual is available on the enclosed application CD and on-line at www.transition.com.
5. To determine if a fault is due to an individual management module or slide-in­module, consult the troubleshooting section of the user’s guide for that particular module.
6. If none of the solutions listed in this section resolves the problem, contact Technical Support: U.S./Canada: 1-800-260-1312, International: 00-1-952­941-7600.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 32
32
CPSMC13xx-100 PointSystem™Chassis
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model CPSMC13xx-100 or equivalent.
Dimensions 17 x 14.3 x 3.5 inches (430 x 363 x 89 mm)
Weight 17.5 lbs. (8.0 kg)
MTBF (Mean Time Before Failure)
Chassis w/ AC Power 88,550 hours (MIL217F2 V5.0 / MIL-HDBK-217F)
223,169 hours (Bellcore 7 V5.0)
Chassis w/ DC Power 277,359 hours (MIL217F2 V5.0 / MIL-HDBK-217F)
577,982 hours (Bellcore 7 V5.0)
CPSMP-120 Power Supply Module
Power Input: 100-240 V, 50/60 Hz, 0.4-1.0 Amp (typical with a fully-loaded chassis) Power Output: +12 VDC at 10.83 Amp maximum.
CPSMP-130 Power Supply Module
Power Input: 48-VDC (38 to 58VDC) @ 2.63 Amp (typical with a fully-loaded chassis) Power Output: +12 VDC at 12.5 Amp maximum.
CPSMP-140 Power Supply Module
Power Input: 24-VDC (20 to 31VDC) @ 4.83 Amp (typical with a fully-loaded chassis) Power Output: +12 VDC at 8.3 Amp maximum.
Environment
Tmra: 0 to 50°C (32 to 122°F) (manufacturer’s rated ambient temperature) Storage Temperature: -40 to 80°C (-40 to 176°F) Humidity 5 to 95%, non condensing Altitude 0 to 10,000 feet
Compliance EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B
UL Listed; 21 CFR Subpart J; CE Mark
Warranty Lifetime
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
The fiber optic transmitters installed in this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with
optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein
may result in hazardous radiation exposure.
Page 33
33
CPSMC13xx-100 PointSystem™Chassis
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Cable Specifications
Null Modem Cable
The Null Modem Cable is used for connecting a terminal or terminal emulator to the management module’s DB-9 connector to access the command-line interface.
The table below shows the pin assignments for the DB9 cable.
Function Mnemonic Pin
Carrier Detect CD 1 Receive Data RXD 2 Transmit Data TXD 3 Data Terminal Ready DTR 4 Signal Ground GND 5 Data Set Ready DSR 6 Request To Send RTS 7 Clear To Send CTS 8
RJ-45 Cable
Category 5:
Gauge: 24 to 22 AWG Attenuation: 22.0 dB /100m @ 100 MHz Maximum Cable Distance: 100 meters
• Straight-through or crossover cable may be used.
• Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network. (RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-)
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a Gigabit Ethernet network.
• Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Page 34
34
CPSMC13xx-100 PointSystem™Chassis
COAX Cable
Coaxial cable media is used for circuits such as DS3, E1 and 10Base-2 Ethernet. The impedance of the coaxial cable is determined by the interface type, for example:
75 ohm for DS3.
50 ohm for 10Base-2 Ethernet.
Special attention should be given to the grounding requirements of coaxial cable circuits. Installation may require grounding at both cable ends or only one cable end or neither cable end.
Cable Shield Grounding
Media converter network cabling my be shielded or unshielded. Shielded cables MUST be grounded according to the specific requirements of the media and port type. For example:
Shielded RJ-45 cable used for 100Base-Tx Ethernet MUST be grounded at both cable endpoints via shielded RJ-45 jacks.
Shielded RS-232 cable MUST have the shield grounded at both cable endpoints via shielded RS-232 connectors.
COAX cable used for 10Base-2 Ethernet MUST only be grounded at a single point.
The media converters provide a jumper option or other grounding mechanism as required. Special attention should be given to the grounding requirements of coaxial cable circuits. Installation may require grounding at both cable ends or only one cable end or neither cable end. See the individual media converter user’s guide for cable/port grounding requirements.
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Page 35
35
CPSMC13xx-100 PointSystem™Chassis
Contact Us
Technical Support
Technical support is available 24 hours a day.
United States: 1-800-260-1312
International: 00-1-952-941-7600
Transition Now
Chat live via the Web with a Transition Networks Technical Support Specialist.
Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides 12-16 seminars per month via live web-based training.
Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail message to our technical support staff.
techsupport@transition.com
Address
Transition Networks
6475 City West Parkway Minneapolis, MN 55344, USA
telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: PointSystem
Chassis
Part Number: CPSMC1300-100, CPSMC1310-100, CPSMC1320-100 Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the
PointSystem™Chassis
to which this declaration refers is in
conformity with the following standards.
CISPR 22:1993; EN 55022:1998; EN 55024:1998 Class A; UL 60950:2000; 21 CFR subpart J;
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
June 14, 2001
Stephen Anderson, Vice-President of Engineering Date
Page 36
36
CPSMC13xx-100 PointSystem™Chassis
Warranty
Limited Lifetime Warranty
This warranty is effective for products shipped May 1, 1999 and after. Every Transition Networks' labeled product purchased after May 1, 1999 will be free from defects in material and workmanship for its lifetime. This warranty covers the original user only and is not transferable.
This warranty does not cover damage from accident, acts of God, neglect, contamination, misuse or abnormal conditions of operation or handling, including over-voltage failures caused by use outside of the product's specified rating, or normal wear and tear of mechanical components. If the user is unsure about the proper means of installing or using the equipment, contact Transition Networks' free technical support services.
To establish original ownership and provide date of purchase, please complete and return the registration card accompanying the product or register the product on­line on our product registration page.
Transition Networks will, at its option:
Repair the defective product to functional specification at no charge,
Replace the product with an equivalent functional product, or
Refund the purchase price of a defective product.
To return a defective product for warranty coverage, contact Transition Networks' technical support department for a return authorization number. Transition's technical support department can be reached through any of the following means:
Contact Tech Support 24-hours a day:
800-260-1312 x 200 or 952-941-7600 x 200
fax: 952-941-2322
email: techsupport@transition.com
live web chat: Transition Now
voice mail: 800-260-1312 x 579 or 952-941-7600 x 579
All messages will be answered within one hour.
Send the defective product postage and insurance prepaid to the following address:
CSI Material Management Center c/o Transition Networks 6103 Blue Circle Drive Minnetonka, MN 55343 USA Attn: RETURNS DEPT: CRA/RMA # ___________
Failure to properly protect the product during shipping may void this warranty. The return authorization number must be written on the outside of the carton to ensure its acceptance. We cannot accept delivery of any equipment that is sent to us
without a CRA or RMA number.
The customer must pay for the non-compliant product(s) return transportation costs to Transition Networks for evaluation of said product(s) for repair or replacement.
Page 37
37
CPSMC13xx-100 PointSystem™Chassis
Transition Networks will pay for the shipping of the repaired or replaced in-warranty product(s) back to the customer (any and all customs charges, tariffs, or/and taxes are the customer's responsibility).
Before making any non-warranty repair, Transition Networks requires a $200.00 charge plus actual shipping costs to and from the customer. If the repair is greater than $200.00, an estimate is issued to the customer for authorization of repair. If no authorization is obtained, or the product is deemed not repairable, Transition Networks will retain the $200.00 service charge and return the product to the customer not repaired. Non-warranted products that are repaired by Transition Networks for a fee will carry a 180-day limited warranty. All warranty claims are subject to the restrictions and conventions set forth by this document.
Transition Networks reserves the right to charge for all testing and shipping incurred, if after testing, a return is classified as "No Problem Found."
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. TRANSITION NETWORKS IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. AUTHORIZED RESELLERS ARE NOT AUTHORIZED TO EXTEND ANY DIFFERENT WARRANTY ON TRANSITION NETWORKS' BEHALF.
Page 38
38
CPSMC13xx-100 PointSystem™Chassis