Transition Networks PointSystem CPSMC0200-221, PointSystem CPSMC0200-226, SPS-1872-SA User Manual

User’s Guide
CPSMC0200-22x
Dual-Slot PointSystem™ Chassis
The Transition Networks CPSMC0200­22x series dual-slot PointSystem™ chassis is designed for installation of two selectable Transition Networks PointSystem™ media converter slide­in-modules. The redundant power
option provides the means to power the chassis from two independent power supplies.
Installation . . . . . . . . . . . . . . . . . .2
Technical Specifications . . . . . . . .4
Troubleshooting . . . . . . . . . . . . . .5
Compliance Information . . . . . . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Part Number Description
CPSMC0200-221
Dual-Slot Point System chassis with two power supplies (one grounded and one ungrounded). The chassis provides Last Gasp
trap generation.
CPSMC0200-226
Dual-Slot Point System chassis with two power supplies (one grounded and one ungrounded).
Optional Accessories (sold separately)
Part Number Description SPS-1872-SA
Optional External Power Supply; 18-60VDC Stand-Alone Output: 12.6VDC, 1.0 A
WMBP
Optional Wall Mount Bracket; Length: 5.0 in. (127 mm)
WMBV
Optional Vertical Mount Bracket: 5.0 in. (127 mm)
WMBD
Optional DIN Rail Mount Bracket: 5.0 in. (127 mm)
2
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0200-22x
Installation
Installing a slide-in-module
CAUTION: DO NOT install Two (2) Point System media converter slide-in-modules with a total power requirement exceeding 12 W (with an average of 6 W per slot). Failure to observe this caution could result in data losses and media converter failure.
CAUTION:
Wear a grounding device and observe electrostatic discharge precautions when installing the media converter slide-in-module into the chassis. Failure to observe this caution could result in damage or failure of the media converter.
Note: If only installing one slide-in-module, ensure network standards compliance by
obtaining a custom faceplate (P/N CPSFP-200) from Transition Networks for installation into the second, unused slot.
To install a slide-in-module into the dual-slot chassis:
1. Refer to the user’s guide that comes with the slide-in-module to ensure that any switches or jumpers on the slide-in-module circuit board are set correctly for the site installation.
2. Carefully align the slide-in-module with the chassis installation guides and slide the module into the installation slot.
3. Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the attached panel faster screw clockwise to secure the slide-in­module to the chassis front.
5. Repeat steps 1-4 for the second slide-in-module.
Panel Fastener Screw
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation -- Continued
Power the chassis
CAUTION:
When using two power supplies to power the chassis, one must be a power supply with an ungrounded secondary. Using two power supplies (with each secondary grounded to protective earth ground) could cause unreliable operation of the chassis and its converters, due to installation specific Protective Ground fault conditions.
Note: The power supply shipped with the chassis has its secondary connected to
protective earth ground. The optional power supply does not have its secondary connected to protective earth. Do Not use two power supplies (with grounded secondaries) to power the chassis.
To supply power to the dual-slot chassis using the power supply:
1. Connect the barrel connector of the power supply (grounded secondary) to one of the dual-slot chassis’ power ports (located on the back of the chassis). See figure below. If using the (grounded secondary) power supply only, go to step 3.
2. Connect the barrel connector of the second power supply (ungrounded secondary) to the dual-slot chassis’ remaining power port.
3. Connect the power supply plug(s) into AC power.
4. Verify that the dual-slot chassis is powered by observing the illuminated LED(s) on the chassis front panel. See the figure below.
Note: If the power supply/supplies are 11VDC or above, the associated LED/LEDs
will be lit (PS1 LED/PS2 LED). If either power supply’s output is under the 11VDC minimum requirement that LED will not turn ON, indicating a problem.
DC power source
To power the dual-slot chassis using the SPS1872-SA DC external power supply, consult the SPS1872-SA user manual at Transition Networks.com.
Last Gasp Option (CPSMC0200-221 models only)
The CPSMC0200-221 models feature the Last Gasp option, which enables the device to send an SNMP trap in the event of a power failure, alerting the management console that the device has failed.
P/ S 2
IN
P/S 1
IN
P/ S 1 LE D
P/ S 2 LE D
Chassis Back Panel Chassis Front Panel