Transition Networks PointSystem CPSMC0100-200 User Manual

User’s Guide
CPSMC0100-200
Single-Slot PointSystem™ Chassis
The Transition Networks CPSMC0100­200 series single-slot PointSystem™ chassis is designed for installation of a single, selectable Transition Networks PointSystem™ media converter slide­in-module.
Installation . . . . . . . . . . . . . . . . . .2
Technical Specifications . . . . . . . .4
Troubleshooting . . . . . . . . . . . . . .5
Compliance Information . . . . . . . .6
Part Number Description CPSMC0100-200 Single-Slot PointSystem™ chassis intended for installation of
any PointSystem media converter slide-in-modules up to 6 W.
Optional Accessories (sold separately)
Part Number Description SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
WMBP Optional Wall Mount Bracket; 5.0 in. (127 mm) WMBV Optional Vertical Mount Bracket; 5.0 in. (127 mm) WMBD Optional DIN Rail Mount Bracket; 5.0 in. (127 mm)
Note: The following media converter families are not compatible with Transition
Networks CPSMC0100-200 single-slot PointSystem™ chassis: C4TEF, CAPTF, CBFTF-120, CBFTF-140, CEMTF, CGFEG and the CMEFG.
2
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0100-200
Installation
Installing a Slide-in-Module
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing the media converter slide-in-module in to the single-slot chassis. Failure to observe this caution could result in damage to, and subsequent failure of, the media converter slide-in-module.
The maximum power delivery capacity for the CPSMC0100-200 is 6 Watts. To install a slide-in-module into the single-slot chassis:
1. Refer to the user’s guide that comes with the slide-in-module to ensure that any switches or jumpers on the module’s circuit board are set correctly for the site installation.
2. Carefully align the slide-in-module with the chassis installation guides and slide the module into the installation slot.
3. Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw to secure the slide­in-module to the chassis.
PWR
RXF
RXC
LKF
100BASE-TX
LKC
RX
TX
100BASE-FX
Panel Fastener Screw
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Power the Chassis
To supply AC power to the single-slot chassis:
1. Connect the barrel connector on the power adapter to the single-slot chassis’ power port (located on the back of the chassis).
2. Connect the power adapter plug to AC power.
3. Verify that the single-slot chassis is powered by observing the illuminated LED(s) on the installed slide-in-module.
To supply DC power to the single-slot chassis:
Consult the user's guide for the Transition Networks SPS1872-xx DC external power supply for powering the single-slot chassis.
4
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0100-200
Installation -- Continued
Grounding the Media Converter
The single-slot chassis comes equipped with grounding lugs located on the back panel. They require a grounding conductor wire terminated with a two­hole, compression-type, grounding connector. The grounding wire -- which must be a copper conductor -- is not included with the chassis and must be provided by the customer/installer.
The electrical conducting path from the single-slot chassis must:
• Flow via the grounding lugs to the common bonding network (CBN) for telecom installations, or to an alternative approved grounding system (if required) for non-telecom installations.
• Be of sufficiently low impedance to conduct fault currents likely to be imposed on the media converter, and
• Enable proper operation of any over-current protection devices.
The conductor must be fastened to the grounding lugs with the enclosed anti­rotation star-washers and lug-nut fasteners. The applied torque required to the connector lug-nut fasteners is specified by the connector’s manufacturer.
To properly ground the single-slot chassis:
1. Obtain one (1) grounding conductor (12 AWG copper wire gauge or larger) with a two-hole, compression-type, grounding connector.
2. Attach the grounding conductor to the converter by placing the two-hole connector onto the grounding lugs and fasten with the enclosed lock­washers / lug-nuts at the proper torque (per the manufacturer’s specification).
3. Attach the opposite end of the grounding conductor to the common bonding network (CBN) for telecom, or to earth ground (if required) for non­telecom installations.
g
rounding lugs
earth ground
grounding connector
and wire
3/4-inch
spacing
Grounding lugs
(6-32, 1/8" diam.)
12 AWG copper wir
e
(not included)
Star washer (included)
Lug nuts (included)
Two-hole, compression-type
grounding connector
(not included)
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Technical Specifications
For use with Transition Networks Model CPSMC0100-200 or equivalent.
Note: The CPSMC0100-200 single-slot chassis is Class B compliant ONLY if
Class B compliant media converters are installed. Installation of a Class A compliant media converter reduces the chassis to Class A compliance.
Compliance EN55022; Class A&B; CE Mark
Dimensions 3.875 x 5.5 x 1.0 in (98 x 140 x 25 mm)
Weight 13 oz. (369 g) approximately
MTBF
CPSMC0100-200: 22,394,241 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
233,811,224 hours (Bellcore7 V5.0)
Maximum power delivery capacity:
CPSMC0100-200: 6 Watts
Power Supply
CPSMC0100-200: 12VDC, 0.8 A (N. America, Europe, Japan, Latin Am.)
12VDC, 1.25 A (UK, Australia, South Africa)
Environment Tmra*: 0 to 50°C (32 to 122° F )
Storage Temp: -20 to 85°C Humidity: 10 to 90%, non condensing Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature.
The information in this user’s guide is subject to change. For the most up-to-date information on the CPSMC0100-200 single-slot chassis, view the user’s guide on-line at: www.transition.com.
6
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
CPSMC0100-200
Troubleshooting
1. Is a media converter installed in the single-slot chassis? NO
• Install a slide-in-module media converter into the single-slot chassis.
See page 2 for installation instructions.
• Proceed to step 2.
YES
Proceed to step 2.
2. Is the Power LED on the media converter illuminated? NO
• Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet? (See “Power Supply” on page 5.)
• Is the power adapter properly installed in the media converter and in
the grounded AC outlet?
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Check the power requirement for the installed media converter?
• If the power requirement is 6 W or less, either model chassis can be
used.
• For additional assistance, contact Technical Support: US/Canada: 1-
800-260-1312, International: 00-1-952-941-7600.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
7
Declaration of Conformity
Name of Mfg: Transition Networks
10900 Red Circle Drive, Minneapolis MN 55343 U.S.A. Model: CPSMC0100-200 Series Single-Slot PointSystem Chassis Part Number: CPSMC0100-200 Regulation: EMC Directive 89/336/EEC Purpose: To declare that the CPSMC0100-200to which this declaration refers is
in conformity with the following standards. EN 55022:1998 Class A&B; EN 55024:1988; FCC Part 15 Subpart B;
EN 61000-3-2:1995; EN 61000-3-3:1995
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
June, 2008
Stephen Anderson, Vice-President of Engineering Date
Contact Us
Technical Support
Technical support is available 24 hours a day United States: 1-800-260-1312 International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff. techsupport@transition.com
Address
Transition Networks 10900 Red Circle Drive Minnetonka, MN 55343, U.S.A. telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2000, 2004 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic or mechanical – without written permission from Transition Networks. Printed in the U.S.A.
33192.E
Compliance Information
CISPR/EN55022 Class A & B + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A & B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference. In which case, the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A & B limits for radio noise for digital appa­ratus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A & B prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.
Loading...