Transition Networks MIL-SW8T1GPA User Manual

Page 1
MIL-SW8T1GPA
8 Port 10/100/1000BASE-T with
Web Managed Switch
User Guide
Rev.A0
19-May-10
Page 2
Regulatory Approval
- FCC Class A
- UL 1950
- CSA C22.2 No. 950
- EN60950
- CE
- EN55022 Class A
- EN55024 Canadian EMI Notice
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada. European Notice
Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community Compliance with these directives imply conformity to the following European Norms:
EN55022 (CISPR 22) - Radio Frequency Interference EN61000-X - Electromagnetic Immunity EN60950 (IEC950) - Product Safety
Five-Year Limited Warranty
Transition Networks warrants to the original consumer or purchaser that each of it's products, and all components thereof, will be free from defects in material and/or workmanship for a period of five years from the original factory shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable. Transition Networks makes no express or implied warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, except as expressly set forth in this warranty. In no event shall Transition Networks be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder. Transition Networks will in no case cover damages arising out of the product being used in a negligent fashion or manner.
Trademarks
The MiLAN logo Transition Networks trademarks are registered trademarks of Transition Networks in the United States and/or other countries.
To Contact Transition Networks
For prompt response when calling for service information, have the following information ready:
- Product serial number and revision
- Date of purchase
- Vendor or place of purchase
You can reach Transition Networks technical support at:
E-mail: techsupport@transition.com Transition Networks 10900 Red Circle Drive Minnetonka, MN 55344 United States of America
Telephone: +1.800.526.9267 Fax: +1.952.941.2322
http://www.milan.com info@ Transition.com
© Copyright 2006 Transition Networks
Page 3
Content
INTRODUCTION..............................................................................3
Features...................................................................................................................3
Software Feature......................................................................................................4
Package Contents....................................................................................................5
HARDWARE DESCRIPTION...........................................................7
Physical dimension ..................................................................................................7
Front Panel ..............................................................................................................7
Rear Panel...............................................................................................................8
LED Indicators..........................................................................................................9
Desktop Installation................................................................................................10
Attaching Rubber Pads...................................................................................10
Power On...............................................................................................................10
NETWORK APPLICATION............................................................ 12
Small Workgroup....................................................................................................12
Segment Bridge .....................................................................................................13
WEB-BASED MANAGEMENT.......................................................15
About Web-based Management.............................................................................15
System Login .........................................................................................................15
System Configuration.............................................................................................16
Port Configuration..................................................................................................18
Statistics Overview.................................................................................................19
Statistics Detail.......................................................................................................20
VLAN Setting..........................................................................................................20
VLAN Port Setting...........................................................................................21
Port Trunk ..............................................................................................................22
LACP Setting..........................................................................................................23
LACP Status ..........................................................................................................24
1
Page 4
Spanning Tree....................................................................................................... 25
RSTP System Configuration...........................................................................25
RSTP Port Configuration................................................................................27
Spanning Tree Status............................................................................................27
802.1X Configuration.............................................................................................28
Parameters Configuration...............................................................................29
QoS Setting...........................................................................................................30
System Restart...................................................................................................... 33
Factory Default ......................................................................................................33
Firmware Upload ...................................................................................................33
Configuration File Transfer....................................................................................34
TROUBLESHOOTING................................................................... 35
Incorrect connections.............................................................................................35
Faulty or loose cables .............................................................................35
Non-standard cables ...............................................................................35
Improper Network Topologies ................................................................. 36
Diagnosing LED Indicators.................................................................................... 36
TECHNICAL SPECIFICATION ...................................................... 37
2
Page 5
Introduction
The 8 10/100/1000T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch that can be used to build high-performance switched workgroup networks. The switch is targeted at workgroup or department.
The 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch features a Store-and-Forward Switching scheme that offers low latency for high-speed networking and allows the switch to auto-learn and store source address in a 8K-entry MAC address table.
The 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo Web Managed Switch has 8 auto-sensing 10/100/1000 Base-TX RJ-45 ports with one auto detect Giga SFP/RJ-45 Combo port that enables extended distance connection.
Features
Conform to IEEE 802.3, 802.3u, 802.3ab, 802.3x and 802.1x  Store-and-Forward switching architecture  True non-blocking switching  Web Management  Auto-MDIX on all ports  16Gbps back-plane  144Kbytes memory buffer  N-Way Auto-Negotiation  8K MAC address table  Back pressure with half duplex  Flow control with full duplex  Support Port Based VLAN  Support Port Trunk
3
Page 6
VLAN
Port Based VLAN  IEEE 802.1Q VLANs. Up to 256 groups
Support DHCP client  Support Class of Service  Support Spanning Tree  9K Jumbo Frame support
Software Feature
Management Web Management
Firmware update Web UI firmware update
One default button for system default Default IP: 192.168.1.77
System default
Subnet Mask: 255.255.255.0 Gateway: 192.168.1.254
IEEE802.3ad port trunk with link aggregation control protocol (LACP)
Port Trunk
The trunk group up to 2 and maximum trunk port member up to 8 ports
Port Based VLAN
VLAN
VLAN ID from 1 to 1095 VLAN group up to 255
DHCP DHCP client feature
4
Page 7
Port based
Quality of Service
Tag based IPv4 Type of Service
Class of Service Per port support 4 priority queues
IEEE802.1w rapid spanning tree and compatible
Spanning Tree
with IEEE 802.1d
Package Contents
Unpack the contents of the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo Web-Smart Switch and verify them against the checklist below: 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo Web Managed
Switch
Power Cord Four Rubber Pads User Manual
8 10/100/1000Base-T + 1 Giga Copper/Mini-GBIC Four Rubber Pads
Web Managed Switch
Power Cord User Manual
Package Contents
Compare the contents of your 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web-Smart Switch package with the standard checklist above. If any
5
Page 8
item is missing or damaged, please contact the local dealer for exchanging.
6
Page 9
Hardware Description
This section mainly describes the hardware of the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web-Smart Switch and gives a physical and functional overview on certain switch.
Physical dimension
The 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch’s physical dimension is
217 x 140 x 43 mm
(L x W x H).
Front Panel
The front panel of the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web-Smart Switch consists of the 7 10/100/1000Base-TX RJ-45 port, one auto detect Giga Copper / Mini GBIC port , LED Indicators and reset button. Please refer to the LED Indicator section for LED description.
Reset button:
 
Restart: Reset to default:
Press the bottom for 3 seconds for system software restarting.
Press 5 seconds for reset back to default value settings.
The front panel of the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed
7
Page 10
Switch
RJ-45 Ports (Auto MDI/MDIX):
7x 10/100/1000 N-way auto-sensing for
10Base-T, 100Base-TX or 1000Base-T connections. In general, connecting to a workstation or PC. Therefore,
means connecting to another Hub or Switch while
MDI
Auto MDI/MDIX
means
MDIX
would allow connecting to another Switch or workstation without changing non-crossover or crossover cabling.
SFP/RJ-45 combo port: The system will automatically detect which is Giga
UTP or Giga fiber. The Giga copper/Mini GBIC combo port is located on front panel which is named as port 1 with 8 10/100/1000Base-TX ports. Giga fiber is the mini GBIC slot that module is optional.
[NOTE]
Disconnect the Giga copper connection before installing the Mini GBIC module. Otherwise, the switch couldn’t detect the Mini GBIC that has been installed. While Giga copper port or Mini GBIC port is operating, only one of them will operate.
Rear Panel
The 3-pronged power plug is located at the rear Panel of 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web-Smart Switch. The switch will work with AC voltage in the range of 100 to 240 volts / 50~60 Hz.
The Rear Panel of 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed
Switch
8
Page 11
LED Indicators
The LED Indicators display real-time information of systematic operation status. The following table provides descriptions of LED status and their meaning.
LED Panel of 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch
LED Status Color Description
Power
1000M
LNK /ACT
On Green Power On
No Power inputs or Power cord
Off --
disconnected The port is operating at the speed of
On Green
1000Mbps The port is operation at the speed of
On Orange
100Mbps In 10Mbps mode or no device
Off --
attached The port is successfully connecting
On Green
with the device The port is receiving or transmitting
Blinks Green
data
FDX /COL
Off -- No device attached
The port is operating in Full-duplex
On Orange
mode
9
Page 12
Collision of Packets occurs in the
Blinks Orange
port Half-duplex mode or no device
Off --
attached The port is successfully connecting
On Green
with the device
LNK /ACT (MINI GBIC)
Blinks Green
Off --
The Description of LED Indicators
The port is receiving or transmitting data
No data transmitted or no device connected
Desktop Installation
Set the switch on a sufficiently large flat space with a power outlet nearby. The surface where the switch locates should be clean, smooth, level and sturdy. Make sure there is enough clearance around the switch to allow attachment of cables, power cord and allow air circulation.
Attaching Rubber Pads
A. Make sure mounting surface on the bottom of the switch is grease and dust
free.
B. Remove adhesive backing from the Rubber Pads. C. Apply the Rubber Pad to each corner on the bottom of the switch. These
footpads can prevent the switch from shock/vibration.
Power On
Connect the power adaptor to the power jag on the rear panel of the switch. The
10
Page 13
other side of power adaptor connects to the power outlet. The external power supply in the switch works with the AC power from 100 to 240V. Please check with the power indicator on the front panel to see if power is properly supplied.
11
Page 14
Network Application
This section provides user a few samples of network topology in which the switch is used. In general, the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch is designed as a segment switch. That is, with its address table (8k MAC address) and high performance, it is ideal for interconnecting networking segments.
PC, workstations, and servers can communicate each other by directly connecting with 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch. The switch automatically learns nodes address, which are subsequently used to filter and forward all traffic based on the destination address.
By using Uplink port, the switch can connect with another switch or hub to interconnect other small-switched workgroups to form a larger switched network. Meanwhile, you can also use fiber ports to connect switches. The distance between two switches via fiber cable depends on the type of fiber transceiver.
Small Workgroup
The 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch can be used as a standalone switch to which personal computers, server, printer server, are directly connect to form small workgroup.
12
Page 15
Segment Bridge
For enterprise networks where large data broadcasts are constantly processed, this switch is an ideal solution for department users to connect to the corporate backbone.
Use two 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch with PCs, print server, and local server attached, are both connecting to the core switch. All the devices in this network can communicate with each other through the core switch. Connecting servers to the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch allows other users to access the data on server. By using fiber ports to connect switches, the distance between two switches depends on the type of fiber transceiver.
13
Page 16
14
Page 17
Web-Based Management
This section introduces the function configuration of the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch.
About Web-based Management
On the CPU board of the switch there is an embedded HTML web site residing in flash memory, which offers advanced management features and allow users to manage the switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer.
The Web-Based Management supports Internet Explorer 5.0. And, it is applied with Java Applets for reducing network bandwidth consumption, enhance access speed and present an easy viewing screen.
[NOTE]
sockets. In fact, the user has to explicitly modify the browser setting to enable Java Applets to operate network ports.
By default, IE5.0 or later version does not allow Java Applets to activate
System Login
The default value is as below:
IP Address:  Subnet Mask:  Default Gateway:  Password:
192.168.1.77
255.255.255.0
root
192.168.1.254
15
Page 18
1. Launch the Internet Explorer
2. Key in “http://” + “IP Address” of the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch, and then press “
Enter
3. Login screen will appear right after
4. Key in the password(The default password is “
root
”)
5. And then, click Apply , and then configuration is ready to be set up
Main Interface
System Configuration
Display system parameters information as listed below, and the other parameters of system can be configured as well. MAC Address: The unique hardware address assigned by manufacturer
(default)
S/W Version: The Software Version of Kernel  H/W Version: The Hardware Version of Switch  Active IP Address: Current IP Address  Active Subnet Mask: Current IP Subnet Mask  Active Gateway: Current Gateway  DHCP Server: DHCP Server IP Address  Lease Time Left: The DHCP lease time. After 50% of the lease time has
passed, the client/switch will attempt to renew the lease with the original DHCP server that it obtained the lease from using a DHCPREQUEST message. Any
16
Page 19
time the client/switch boots and the lease is 50% or more passed, the client/switch will attempt to renew the lease. At 87.5% of the lease completion, the client/switch will attempt to contact any DHCP server for a new lease
DHCP Enable:
Fallback IP Address:
192.168.1.77)
Fallback Subnet Mask:
Fallback Gateway:
192.168.1.254)
Management VLAN:
System Configuration interface
To enable DHCP Client Function
Assigning the switch IP address(The default IP is
Assigning the switch IP Subnet Mask
Assigning the switch Gateway(The default value is
It is used for Remote Management Security; in fact, it can
17
Page 20
remote management that include telnet, SNMP, and Web browse the switch only when the port of VLAN group ID is equal to the Management VLAN ID
Name:
Password:
Inactivity Timeout:
And then, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
the name of the switch
Web GUI login password. The default password is root
The web connection timeout time
Port Configuration
Configure the port of status.
Link:
10FDX, 10HDX, Down)
Mode:
Display the current connection speed(1000FDX, 100FDX, 100HDX,
Set the Auto Speed, 1000 Full mode of the port
Flows control:
mode
MaxFrame(1518 ~ 9600):
received on the port. Tagged frames are allowed to be 4 Bytes longer than the Maximum Frame Size
And then, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
Set Flow Control function is “enable” or “disable” in Full Duplex
The Maximum Frame Size that in Bytes fro frames
18
Page 21
Port Configuration interface
Statistics Overview
The following information provides the current port statistic information
Press
And then, click Refresh to get the new setting information as below:
Clear
button to clean all counts
Statistics Overview interface
19
Page 22
Statistics Detail
The following information provides statistic detail information of statistic on each port, and simply selecting the port to viewing the statistic information.
Press
And then, click Refresh to get the new setting information as below:
Clear
button to clean all counts
Statistics Detail interface
VLAN Setting
A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which would allows user to isolate network traffic so only the members of VLAN will receive traffic from the same members of VLAN. Basically, creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch. However, all the network devices are still plugged into the same switch physically.
Assign the VLAN ID  Grouping the members of VLAN
Click Add All Port to add all of the ports into a VLAN entry.
Click Clear All Port to clear all of check box for canceling all the ports to be
added into a VLAN entry.
20
Page 23
And then, click Apply to bring up the configuration interface as below:
VLAN Setting interface
VLAN Port Setting
Click VLAN Port Setting to bring up the configuration interface for adjusting the VID Setting
PVID:
Awareness:
Enter the Port VLAN ID
Enable the awareness that ports will strip the VLAN tag from received frames and insert the tag in transmitted frames (PVID). Disable the awareness that ports will not strip the tag from received frames or insert the tag
21
Page 24
in transmitted frames
Frame Type:
To set the outgoing frames
Tagged: Outgoing frames with VLAN-Tagged  All: All type of frames
After that, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
VLAN Port Setting interface
Port Trunk
Port trunk allows multiple links to be bundled together and act as a single physical link for increased throughput. It provides load balancing, and redundancy of links in a switched inter-network. Actually, the link does not have an inherent total bandwidth equal to the sum of its component physical links. Traffic in a trunk is distributed across an individual link within the trunk in a deterministic method that called a hash algorithm. Traffic pattern on the network should be considered carefully before you apply it. When a proper hash algorithm is used, traffic is kind of randomly decided to be transmitted across either link within the trunk and load balancing will be seen.
22
Page 25
Grouping the members of Trunk. Normal means the port is not trunk port  And then, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
Port Trunk interface
LACP Setting
The Link Aggregation Control Protocol (LACP) provides a standardized means for exchanging information between Partner Systems on a link to allow their Link Aggregation Control instances to reach agreement on the identity of the Link Aggregation Group to which the link belongs, move the link to that Link Aggregation Group, and enable its transmission and reception functions in an orderly manner. Link aggregation lets user group up to eight consecutive ports into a single dedicated connection. This feature can expand bandwidth to a device on the network.
LACP operation requires full-duplex mode,
refers to IEEE 802.3ad.
more detail information
Protocol Enable:
Key Value:
together
To enable the LACP protocol of the port
The LACP key determines which ports potentially can aggregate
And then, click Apply to apply the configuration
23
Page 26
Or, click Refresh to reset the configuration before applying
LACP Setting interface
LACP Status
When the LACP aggregator had been setup, the LACP status information will display as below:
24
Page 27
LACP Status interface
Spanning Tree
The Rapid Spanning Tree Protocol (RSTP) is an evolution of the Spanning Tree Protocol and provides for faster spanning tree convergence after a topology change. The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol.
RSTP System Configuration
System Priority:
A value used to identify the root bridge. The bridge with the
25
Page 28
lowest value has the highest priority and is selected as the root. If the value has being changed, user has to reboot the switch. The value must be multiple of 4096 according to the protocol standard rule.
Hello Time (1-10):
The scale of 1~10 sec will be set as a period of time that
how often the switch broadcasts hello messages to other switches
Max Age (6-40):
The number of seconds (from 6~ 40) which determines the amount of time that protocol information received on a port is stored by the switch.
Forward Delay Time (4-30):
The number of seconds (from 4 ~ 30) which determines how long each of the listening and learning states will last before the port begins forwarding.
Force version:
Select the RSTP default protocol. Normal means RSTP
protocol. Compat is for compatibling with STP protocol.
RSTP Configuration interface
26
Page 29
RSTP Port Configuration
Protocol Enable: To
Edge:
in the network. To configure the port as an edge port, mark the port
Path Cost:
at the specified port. Enter a number 1 through 200000000
And then, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
The port directly connected to end stations cannot create bridging loop
The cost of the path to the other bridge from this transmitting bridge
enable or disable the port protocol
Spanning Tree Status
Click Refresh to get the newest configuration information. Also, the RSTP VLAN Bridge information will display as below:
27
Page 30
RSTP Status interface
802.1X Configuration
802.1x is an IEEE authentication specification that allows a client to connect to a wireless access point or wired switch but prevents the client from gaining access to the Internet until it provides credentials, like a user name and password that are verified by a separate server.
Mode:
RADIUS IP:
RADIUS UDP Port:
To disable or enable 802.1x protocol
Set the Radius Server IP address
Set the UDP destination port for authentication requests to
the specified Radius Server
RADIUS Secret:
Set an encryption key for use during authentication sessions with the specified radius server. This key must match the encryption key used on the Radius Server
Admin State:
Force Authorized:
Select the state of port
The specified port is required to be held in the
unauthorized state
Force Unauthorized:
The specified port is required to be held in the
authorized state
Auto:
The specified port is set to the authorized or unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server
Re-authenticate:
Force Reinitialize:
Statistics:
Re-authenticate All:
Force reinitialize All:
Click to view each port statistic
Restart authentication process for the port
Restart a complete authentication process for the port
Restart authentication process for all the port
Restart a complete authentication process for the port
And then, click Apply to apply the configuration
28
Page 31
Or, click Refresh to reset the configuration before applying
802.1X Configuration interface
Parameters Configuration
Reauthentication Enable: To
Reauthentication period (1~3600 seconds):
which clients connected must be re-authenticated
EPA Timeout (1~255 seconds):
supplicant response to an EAP request
And then, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
enable the re-authentication mode
Set the period of time after
Set the period of time the switch waits for a
29
Page 32
QoS Setting
Configuring QoS mode of the port and per port priority, TOS and COS priority setting.
Mode:
Port Priority:
And then, click Apply to apply the configuration
Or, click Refresh to reset the configuration before applying
Select the QoS mode – port, DSCP, or vlantag
Select the priority level – low, normal, medium, or high
30
Page 33
Refesh
QoS Configuration interface
Click DSCP Mapping to enter TOS priority configuration interface
DSCP [0- 63]:
The system provides 0~63 TOS priority level. When the IP packet is received, the system will check the TOS level value in the IP packet that has received. For example: user set the TOS level 25 is high. The port 1 is following the TOS priority policy. When the packet received by port 1, the system will check the TOS value of the received IP packet. If the TOS value of received IP packet is 25(priority = high), and then the packet priority will have highest priority
Priority:
Select the priority level – high, medium, low, or normal
And then, click Apply to apply the configuration
Or, Click
to reset the configuration before applying
31
Page 34
QoS DSCP Mapping interface
Click VLAN tag Mapping to enter VLAN tag priority configuration interface.
Select the VLAN tag priority level: High, Medium, Normal and Low.
And then, click Apply to apply the configuration
Or, press Refresh to reset the configuration before applying
QoS VLAN Tag Priority Mapping interface
32
Page 35
System Restart
Reboot the switch in software reset. All the configurations will be reminded Click Yes to restart the system
System Restart interface
Factory Default
Reset switch to default configuration Click Yes to reset the all configuration to the default value
Factory Default interface
Firmware Upload
The system provides the Web GUI firmware update function which would allow the user to update the switch firmware.
Click
Browse
to locate the firmware
33
Page 36
And then, press
Upload
to update the firmware
Firmware Upload interface
Configuration File Transfer
The system provides the Web GUI configuration upload function which would allow the user to backup the switch configuration.
Click
Browse
to locate the path for Uploading
And then, press
And then, press
Upload
Download
Firmware Upload interface
to update the configuration file
to download the configuration file
34
Page 37
Troubleshooting
This section is intended to help user solve the most common problems on the 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch with.
Incorrect connections
The switch port can auto detect straight or crossover cable when link switch with other Ethernet device. For the RJ-45 connector should use correct UTP or STP cable, 10/100Mbps port use 2 pairs twisted cable and Gigabit 1000T port use 4 pairs twisted cable. If the RJ-45 connector is not correct pin on right position then the link will fail. For fiber connection, please notice that fiber cable mode and fiber module should be match.
Faulty or loose cables
Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug. IF that does not correct the problem, try a different cable.
Non-standard cables
Non-standard and miss-wired cables may cause numerous network collisions and other network problem, and can seriously impair network performance. A category-5 cable tester is a recommended tool for every 100Base-T network installation.
RJ-45 ports:
for RJ-45 connections: 100
use unshielded twisted-pair (UTP) or shield twisted-pair ( STP ) cable
Ω
Category 3, 4 or 5 cable for 10Mbps connections or
35
Page 38
100Ω Category 5 cable for 100Mbps connections. Also be sure that the length of any twisted-pair connection does not exceed 100 meters (328 feet). Gigabit port
should use Cat-5 or cat-5e cable for 1000Mbps connections. The length does not exceed 100 meters.
Improper Network Topologies
It is important to make sure that have a valid network topology. Common topology faults include excessive cable length and too many repeaters (hubs) between end nodes. In addition, user should make sure that the network topology contains no data path loops. Between any two ends nodes, there should be only one active cabling path at any time. Data path loops will cause broadcast storms that will severely impact the network performance.
Diagnosing LED Indicators
The switch can be easily monitored through panel indicators to assist in identifying problems, which describes common problems may encounter and where can find possible solutions.
If the power indicator does turn on when the power cord is plugged in, it may have a problem with power outlet, or power cord. However, if the switch powers off after running for a while check for loose power connections, power losses or surges at power outlet. If the problem still cannot be solved, contact the local dealer for assistance.
36
Page 39
Technical Specification
This section provides the specifications of 8 10/100/1000Base-T with 1 1000Base-X SFP/RJ45 Combo port Web Managed Switch with.
IEEE 802.3 10BASE-T Ethernet IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3ab 1000Base-T IEEE 802.3z Gigabit Fiber IEEE 802.3x Flow Control and Back-pressure
Standard
IEEE 802.1w Rapid Spanning Tree IEEE 802.3ad Port trunk with LACP IEEE 802.1p Class of Service IEEE 802.1x user authentication IEEE 802.1q Port VLAN Tag
Protocol CSMA/CD
Technology Store-and-Forward switching architecture
14,880 pps for 10Mbps
Transfer Rate
148,800 pps for 100Mbps 1,488,000 pps for 1000Mbps
Per RJ-45 port: 100/1000
LED Indicators
Link/Activity Full duplex/ Collision
Per MINI GBIC: Link/Activity
37
Page 40
Network Cable
Connector
Per unit: Power
10BASE-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
100BASE-TX: 2-pair UTP/STP CAT. 5 cable
EIA/TIA-568 100-ohm (100m)
Gigabit Copper: 4 pair UTP/STP CAT. 5 cable
EIA/TIA 568 100-ohm (100M)
Gigabit copper: 8 x RJ-45 with Auto-MDIX SFP port: 1 x SFP slot (3.3v)
Back-plane 16Gbps
MAC address 8K Mac address table
Memory Buffer 144Kbytes
Jumbo packet Support 9Kbytes jumbo frame
Dimensions 250mm(W) x 133mm(D) x 37mm(H)
Power Supply Internal power AC 100~240V / 50~60Hz
Power Consumption 4.8 Watt (maximum)
Operating
0 to 45 (32 to 113 )
Temperature
38
Page 41
Operating Humidity 10% to 90% (Non-condensing)
FCC Class A
EMI
CE
UL
Safety
cUL
10900 Red Circle Drive Minnetonka, MN 55344
Tel.: +1.952.941.7600
techsupport@transition.com
39
Loading...